Operation mode
AUTO :
The POWER indicator blinks at the initial stage.
The unit will select an operation mode every 10 minutes depending on the setting and room
temperature.
HEAT :
The POWER indicator blinks at the initial stage. The unit will take some time to warm up.
COOL :
Provides ef
fi
cient comfort cooling to suit your needs.
DRY
:
Operates at low fan speed for a gentle cooling operation.
Energy saving temperature setting
You may save energy when operating the unit within the recommended temperature range.
HEAT :
20.0 °C ~ 24.0 °C / 68 °F ~ 75 °F.
COOL:
26.0 °C ~ 28.0 °C / 79 °F ~ 82 °F.
Air
fl
ow direction
In COOL/DRY mode:
The horizontal
fl
ap is
fi
xed at middle position setting.
Once the temperature is achieved, the horizontal
fl
ap swings up/down automatically.
In HEAT mode:
If AUTO is set, the horizontal
fl
ap is
fi
xed at the predetermined position. The vertical
fl
ap swings
left/right after the temperature rises.
In COOL/HEAT/DRY mode:
The horizontal
fl
ap swings up/down automatically.
Auto restart control
When power is resumed after a power failure, the operation will restart automatically with the last
operation mode and air
fl
ow direction.
• This control is not applicable when TIMER is set.
Operating conditions
Use this air conditioner in the temperature range indicated in the table.
Temperature °C (°F)
Indoor
Outdoor
DBT
WBT
DBT
WBT
COOL
Max.
32 (89.6)
23 (73.4)
46 (114.8)
26 (78.8)
Min.
16 (60.8)
11 (51.8)
16 (60.8)
11 (51.8)
HEAT
Max.
30 (86.0)
-
24 (75.2)
18 (64.4)
Min.
16 (60.8)
-
-5 (23.0)
-6 (21.2)
DBT: Dry bulb temperature, WBT: Wet bulb temperature