Press the POWER keypad to turn the unit on/off.

(The TIMER keypad controls the auto start/stop feature of the unit.)

Press the "MODE" keypad to select the appropriate operating mode.  The mode selection 

will alternate between  AUTO, HEAT, COOL, FAN and DRY. The green indicator light beside 

the "MODE" option will illuminate, identifying the mode selected.

When using the DRY and AUTO mode, you cannot select a fan speed. The fan motor

operates on LOW speed in DRY mode and on MED speed in AUTO mode.Some models

wihtout MED speed,the fan motor operates on HIGH speed in AUTO mode.
    

Press the     keypad to increase the set (operating) temperature of the unit. 

Each time the keypad is pressed the temperature increases as follows:

O

O

1 C (Celsius Scale) Maximum Setting 30 C
  

Press the     keypad to decrease the set (operating) temperature of the unit. 

Each time the keypad is pressed the temperature decreases as follows:

O

O

1 C (Celsius Scale) Minimum Setting 17 C

Press this keypad to activate the appropriate fan speed setting. Each depression of the 

keypad will alternate through LOW, MED(some models without), HIGH fan speed options. 

The green indicator light beside the FAN speed option will illuminate, identifying the fan

 speed selected.

Press the "TIMER" keypad to activate the "auto start/auto stop" timer function. 

Auto start/stop programs can be set from 0~24 hours. Each depression of the "TIMER" 

keypad will increase or decrease the selected time in 0.5 hour increments up to 10 hours,

then by 1 hour increments up to 24 hours.

Press the "SWING" keypad  to activate the automatic air swing (oscillation) feature. The 

green indicator light adjacent to the "SWING" keypad will illuminate, identifying to the selected

 mode is operational. The vertical louvers will oscillate back and forth (side to side) 

automatically sweeping air alternately for comfortable cooling. To stop the air swing feature, 

press the "SWING" keypad again, the green indicator light adjacent to the keypad will go off.

Press the "SWING" keypad for 2 seconds will activate the SLEEP mode which can reduce

noise creating a comfortable sleeping environment. 

When the SLEEP mode is activated, the green indicator light beside the "SLEEP" function

will illuminate. 

Summary of Contents for RC-X9U

Page 1: ...LL TYPE R O O M A IR CO N D ITIO N ER R 410A W IN D O W W A LL TYPE R O O M A IR CO N D ITIO N ER R 410A W IN D O W W A LL TYPE R O O M A IR CO N D ITIO N ER R 410A W IN D O W W A LL TYPE R O O M A IR...

Page 2: ...perience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play the appliance Cleani...

Page 3: ...ol the entire house It may cause explosion fire and burns It may cause electric shock or fire due to heat generation It may cause electric shock It may cause failure of machine or electric shock It ma...

Page 4: ...s food pets plants and art objects It may cause deterioration of quality etc It may cause failure of product or fire Do not use for special purposes Turn off the main power switch when not using the u...

Page 5: ...juries can occur when handling sharp metal edges 2 Do not use water to clean inside the air conditioner Exposure to water can destroy the insulation leading to possible electric shock 3 When cleaning...

Page 6: ...ions are the same The following illustration is for explanation purpose only the actual shape of the machine you purchased may be slightly different NOTE All the illustrations in the manual are for ex...

Page 7: ...to discharge stale air The electronic control keypad will look like one of the following CLOSE VENT OPEN To open the vent pull the lever toward you To close it push it in To open the vent set the lev...

Page 8: ...d setting Each depression of the keypad will alternate through LOW MED some models without HIGH fan speed options The green indicator light beside the FAN speed option will illuminate identifying the...

Page 9: ...on AUTO mode the fan motor will changed into LOW speed mode immediately ECONOMY SLEEP For the models with SWING feaure press and hold the ECONOMY keypad for 2 seconds or use the remote control to acti...

Page 10: ...t failure The air filter behind the inlet grille should be checked and cleaned at least once every 2 weeks or as necessary to maintain optimal performance of the air conditioner How to remove the air...

Page 11: ...abinet and attach to the back drain hole For the units without the bottom rubber plug just install the drain tray 2 Take out the drain tray and screws which provided with your air conditioner accessor...

Page 12: ...r will greatly reduce the cooling and heating efficiency of the air conditioner 4 Install the unit a little obliquely outward not to leak the condensed water into the room about 10mm or 1 4 bubble wit...

Page 13: ...ICK CUT AWAY TO CLEAR LOUVRES FRONT AIR OUT AIR IN AIR IN TOP VIEW O 45 BRICK CUT AWAY TO CLEAR LOUVRES 100mm BRICK WALL 100mm OPTION B Step 1 Remove the air conditioner from it s packaging remove fix...

Page 14: ...inet See Fig 8 5 Install the two chassis fixing brackets using the two fixing screws See Fig 5 Step 4 Install the frame 1 Install the frame and connect the coupler plugs making sure not to interfere w...

Page 15: ...ompressor has cycled off The fuse is blown circuit breaker is tripped Check the house fuse circuit breaker box and replace the fuse or reset the breaker Power failure If power failure occurs switch of...

Page 16: ...15 SPECIFICATIONS Model Unit Dimension mm W x H x D Wirning Size m m 2 450x346x585 3 1 5 RC X7U Cooling Capacity Btu h 7000 RC X9U 9000 450x346x585 3 1 5...

Page 17: ...EN IEC...

Page 18: ......

Page 19: ...3...

Page 20: ...O 18 43 C T1 O 17 32 C T1...

Page 21: ...5 1 1 1 2...

Page 22: ...LED...

Page 23: ......

Page 24: ...8 AUTO SLEEP LOW AUTO...

Page 25: ...9 2 1 2 3 40 4 2406 5666...

Page 26: ...1 2 3 90 4...

Page 27: ...11...

Page 28: ......

Page 29: ......

Page 30: ......

Page 31: ...15 mm 2 RC X7U 3 1 5 450x346x585 2406 5666 Btu h 7000 mm 3 1 5 450x346x585 RC X9U 9000...

Page 32: ...NG NEW TERRITORIES HONG KONG Tel 852 2406 5439 Fax 852 2408 1389 193 199 5 I AVENIDA DE VENCESLAU DE MORAIS NO 193 199 5 ANDAR I EDF INDUSTRIAL NAM LENG MACAU Tel 853 2836 2928 Fax 853 28336405 www sh...

Reviews: