Always use at the rated voltage and with a specific air conditioning circuit.
This equipment must be earthed and strongly recommended to be installed with Earth Leakage Circuit Breaker
(ELCB) or Residual Current Device (RCD). Otherwise, it may cause electric shock or fire in case of malfunction.
Time delay fuse or circuit breaker rating is 16 Ampere for RC-N1221V.
Nominal cross sectional area of power supply wire must be 3 core x 1.5 mm
2
or above.
The power supply must be from an independent circuit.
All electrical installations must be made in accordance with local wiring and safety regulation wherever applicable.
There must be a double pole switch with a minimum of 3.5 mm contact gap in the fixed installation circuit.
Please engage and authorized dealer or specialist for the installation work.
ELECTRIC WORK
This air conditioner employs a “Slinger-Up System” which is designed to splash the condensed water on the condenser coil
for maximum cooling efficiency, thus producing a splashing sound. If the splashing sound annoys you, you can provide an
outside drainage by using the following the procedure which may, cause a small loss of performance.
NOTE: If the unit is installed at a coastal area, drainage of condensed water is recommended to prevent easy condenser corrosion.
NOTE:
Remove the rubber plug and chassis locking bracket*2
from the cabinet. Then slides the chassis out from the
cabinet.
1
Connect a drain hose. Fit the drain hose to the drain pan.
Underside view with drain
pan and hole in place.
Drain Hose
3
Slide the chassis back into the cabinet. Lock the chassis to the cabinet
reusing the chassis locking bracket*2. Reinstall the cabinet and chassis.
4
Install the drain pan
Install the drain pan at the
right corner of the cabinet
using 2 screws.
2
Drain hose or tubing can be purchased locally to satisfy
your particular needs.
Screws
Drain pan
INTERNAL VIEW
5
6
7
ACXF55-32500
NOISE CONSIDERATION
Select an installation location that can support the weight of the air
conditioner and one that will not cause increased operating noise
and vibration.
Ensure that when installed, airflow and noise from the rear side of the
unit (outdoor) do not disturb neighbouring elements.
Obstacles placed in front of the air outlet on the rear side of the unit
(outdoor), or covers placed over it will cause excessive noise and
deterioration in performance.
TRANSFERRING
Repositioning or transfer of the air conditioner due to renovation or moving requires an additional
service charge. Please consult your dealer before moving.
ENERGY SAVING HINTS
Do not overcool the room. This may affect your well-being as well as increase power consumption.
The cooling capacity of the room air conditioner must match the room size for efficient and
satisfactory operation.
Keep all doors and windows closed. Prevent hot air from entering and cool air from escaping.
Ensure that curtains and drapes are always closed to keep out direct sunlight during cooling operation.
Avoid heat.
Clean the air filter every 2 weeks. Dirty filters may reduce cooling efficiency.
CARE AND MAINTENANCE
Clean the cabinet, front grille with mild soap or detergent and lukewarm water.
NOTE: Do not dry the front panel or the air filter in direct sunlight.
(Exposure to direct sunlight may discolour or deform the panel.)
If the air filter becomes clogged with dust, the cooling capacity will drop, and 6% of the electricity used to
operate the air conditioner will be wasted.
If the unit is extremely dirty, heat transfer is less effecient and the unit may not cool effectively. Contact
Shun Hing Electric Service Center Ltd. for an annual check. (Annual check is not covered by the warranty.)
Do not clean with benzene, thinner, scouring powder or cloth soaked in caustic chemicals.
The filter can be easily cleaned using a vacuum cleaner. Vacuum the front of the filter and then wash the
rear with water. If it is badly spoiled, wash with a mild household detergent.
The front intake grille can be easily removed for cleaning purposes (refer to Remove the front intake
grille procedures). Gently wash it with water and a sponge.
PRE-SEASON INSPECTION
Is the discharged air cold?
Are the air intake and outlet vanes of the indoor and outdoor side obstructed?
Are the remote control batteries weak?
After 15 minutes of operation, it is normal for the temperature difference between intake and outlet air
to be more than 8
°
C for cooling.
RECOMMENDED INSPECTION
BEFORE CALLING FOR SERVICE
Usage over several seasons will reduce performance as the unit becomes dirty. A dirty unit may produce foul
odours and dust may clog the dehumidifying drainage. Seasonal inspection is recommended in addition to
regular cleaning. Consult Shun Hing Electric Service Centre Ltd.,
Check the following points before calling for repairs or service.
If the malfunction persists, please contact Shun Hing Electric Service Centre Ltd.,
OFTH0810-00
Printed in Philippines
INSTALLATION PROCEDURES
CONDENSED WATER DRAINAGE
Slide the chassis into the cabinet.
Lock the chassis to the cabinet reusing the
chassis locking brackets.
Depending upon the location of AC outlet,
route the AC cord to either left or right side
before instaling the front grille.
Attach the front grille to the cabinet
and fasten it with a screw.
Attach air filter to the front grille.
(see Anti-bacterial filter installation
instructions included in this package)
Remove the rear cabinet screws and two chassis locking
brackets from the cabinet. Save for later use.
1
8
9
Slide the chassis out from the cabinet.
2
Place the cabinet into the installation hole.
3
4
5
7
x2
Remove the
rubber plug
Counter
clockwise
Chassis locking
bracket
Front Grille Fulcrum
Body Support
Grille Force arm
Counter clockwise
Chassis locking bracket.
6
This figure shows the AC cord routed to the left side.
Insert front grille tabs
into the cabinet slots
Position the intake grille horizontally and hook the
front grille fulcrum to the grille force arm.
10
Note for the battery symbol (bottom two symbol examples):
This symbol might be used in combination with a chemical symbol. In this case it complies with the
requirement set by the Directive for the chemical involved.
To call Shun Hing Electric Service Centre Ltd. IMMEDIATELY
Turn off the power and contact Shun Hing Electric Service Centre Ltd.
as soon as any of the following events occur.
The circuit breaker frequently trips or the fuse blows regularly.
If water or foreign objects have accidentally entered the air conditioner.
If there is abnormal sound during operation.
NOTE:
1. The enclosure opposing the room side is splash proof (IPX4).
2. Do not install this appliance in a laundry room or other locations where water may drip from the ceiling, etc.
3. If the supply cord is damaged or need to be replaced, it must be replaced by the manufacturer or its service
agent or a similarly qualified person in order to avoid a hazard.
Green Yellow: Earth Blue: Neutral Brown: Live
“As the coulours of the wires in the mains lead of this appliance my not correspond with the coloured markings identifying the terminals in your plug,
proceed as follows:
The wires which is coloured green and yellow must be connected to the terminal in the plug which is marked by the letter E or by the safety earth
symbol or coloured green or green and yellow. The wire which is coloured blue must be connected to the terminal which is marked with letter N
or coloured black. The wire which is coloured brown must be connected to the terminal which is marked with letter L or colour red.”
(NOTE: Replacement of installation of power plug shall be performed only by authorized/qualified personnel.)
IMPORTANT
* The wires in this mains lead are coloured in accordance with the following code:
If the unit is too noisy during operation.
The following sounds are normal during operation:
A low humming sound indicating that the unit is operating.
A splashing sound indicating condensation in the
condenser coil.If you hear other noises, please consult
Shun Hing Electric Service Centre Ltd.,
A flowing sound due to circulation of the refrigerant when
the compressor is turned on.
A soft clicking sound when the compressor turns on and off.
Condition
1
Information for Users on Collection and Disposal of Old Equipment and used Batteries
Condition
2
If the unit does not operate.
The main power cord is not plugged in.
The main circuit breaker has tripped.
Condition
3
If the unit does not cool properly.
The room is too big for the unit’ s capacity.
The ventilation lever is set to OPEN
The air circulation is impeded by curtains or furniture.
After 15 minutes of operation, it is normal for the temperature
difference between intake and outlet air to be more than 8
°
C
for cooling.
[Information on Disposal in other Countries outside the European Union]
These symbols are only valid in the European Union. If you wish to discard these items, please contact
your local authorities or dealer and ask for the correct method of disposal.
If water drips inside the room.
Condition
5
The unit is tilted inward. To rectify this, tilt the unit slightly outward.
Mount the optional drain pan if you prefer.
The drain pan may be blocked.
Condition
6
Squeaking noise during operation,
Squeaking noise after shutting down
(This is due to the expansion or contraction of the model
due to temperature changes)
If water drips off the rear of the unit.
Humidity is high.
Condensed water is overflowing.
To rectify the problem, mount an optional drain pan to the unit.
Condition
4
■The air conditioner blows out cold misty
air, and the indoor air comes into contact
with the cold air blown out of low
temperature to produce misty air.
■There seems to be a sound of running
water. This is the sound of the
refrigerant flowing inside the air
conditioner.
■Occasionally there is the sound of "GI-GA",
the expansion
and contraction
of the front leaf
window due to
temperature
changes.
Press down control panel and close the cover.
x2
x2
Clockwise
x2