Rasmussen RF-RF-LD30/36-VEI-N/P Owner'S Manual Download Page 16

16

 

 

LIMITED WARRANTY: 

 

RASMUSSEN IRON WORKS INC, 12028 E. Philadelphia Street, Whit-

tier  California,  U.S.A.,  warrants  this  Gas  Log  Set  and  accessories 

against defects in materials and workmanship, and suitable for a  

particular purpose, for a period of: 

 

Home (Non-Commercial use):

 

 

(1)  LOG  CASTINGS  -  All  logs  are  guaranteed  against  crumbling  in 

the original installation for the lifetime of the initial purchaser. 

 

(2)  BURNERS/GRATES  - 2 Years from date of purchase. 

 

(3)  SAFETY CONTROLS - Pilots and Safety Controls are covered by 

warranty of the original manufacturer only. 

 

 

Commercial Use: 

All components - 1 year from date of purchase 

 

 

THIS  WARRANTY IS FOR THE BENEFIT OF THE ORIGINAL  

PURCHASER. 

 

WARRANTY ADJUSTMENT: 

 

(1)  RASMUSSEN  agrees  to  repair  or  furnish  a  replacement  for,  but 

not  remove  or  install  any  product  or  component  which  proves 

defective within the above warranty and appropriate time  

        periods stated. 

 

(2)  BUYER notify RASMUSSEN of any defect within this warranty   

        no later than thirty (30) days after a defect is discovered. 

 

(3)  No product will be accepted for return or replacement without  

        written authorization of RASMUSSEN. Before returning  

        merchandise, write to RASMUSSEN Giving us full details of the    

        complaint and a copy of  the sales receipt or other evidence of 

        the purchase date. Merchandise returned without proof of  

        purchase date will be serviced out-of-warranty at our prevailing  

        service and parts rates. If merchandise was damaged in transit, 

        the file claim must be addressed as follows: 

 

 

 

 

 

 

Shipping 

charges must 

be pre-paid by the buyer.  

REPAIR OR REPLACMENT UNDER THIS  WARRANTY WILL BE 

SHIPPED FREIGHT COLLECT. 

EXCLUSIONS FROM WARRANTY: 

(1)  The foregoing warranty is limited solely as set forth herein and  

        applies only for the designated above. 

 

(2)  RASMUSSEN shall not be liable for any loss, damage incidental 

        or consequential damages of any kind, whether based upon  

        warranty, contract, or negligence, arising in connection with the   

        sale, use or repair of the product. Some states do not allow the  

        exclusion or limitation of incidental or consequential damages, so  

        the above limitation or exclusion may not apply to you. 

 

(3)  The maximum liability  of RASMUSSEN in connection with this  

         limited warranty shall not in any case exceed the contract price   

         paid for the product claimed to be defective or unsuitable. 

 

(4)  This warranty does not extend to any product manufactured by  

        RASMUSSEN which has been subjected to misuse, neglect,  

        accident improper installation, or use in violation of instructions    

        furnished by RASMUSSEN. 

 

(5)  This warranty does not extend to or apply to any unit which has 

been  repaired  or  altered  in  any  place  other  that  RASMUSSEN 

IRON WORKS INC. factory, or by persons not expressly  

        approved by RASMUSSEN. 

 

(6)  Components manufactured by any supplier other than  

        RASMUSSEN shall bear only that warranty made by the  

        manufacturer of that product. 

 

(7)  Freight damage, cracking from thermal shock, and color changes 

occur from causes beyond manufacturer’s control and are not 

 

        covered by any warranty. 

 

 

 

 

 

 

 

THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU 

MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO 

STATE. 

 

 

RASMUSSEN  IRON  WORKS,  INC.  shall  be  held  harmless  from 

any and all claims by the buyer as a result of injury or damage to 

an Ultimate user or other person caused by the  product sold here-

in by the seller to the buyer, whether the injury or damage results 

from the assembly, product installation, operation, shipment, stor-

age or manufacture of this product. RASMUSSEN IRON WORKS, 

INC. makes no warranties, expressed or implied, other than those 

expressly stated herein. 

RASMUSSEN IRON WORKS INC 

12028 E. PHILADELPHIA STREET  

WHITTIER, CALIFORNIA   90601 

* CUSTOMER RESPONSIBILITY * 

Your Gas Log is designed to burn with a natural smoky yellow flame that produces carbon soot. Like a wood fire,  

burning a Gas Log with the flue blocked or closed will cause fumes and smoke to remain in the room and  

cause health hazards. 

 

DAMPER MUST BE FULLY OPEN WHEN BURNING A GAS LOG SET.  

LIMITED LIFETIME CONSUMER PRODUCT WARRANTY 

 

 

The following warranty has been drafted to comply with the MAGNUSON-MOSS WARRANTY ACT applicable  

to products manufactured after July 4, 1975, It replaces and supersedes any warranty in this package or in any printed literature. 

®

 

CONSUMER RECORD CARD 

 

Please record and retain information for future reference. Register your product at www.rasmussen.biz 

 

LOG MODEL: 

 

SAFETY CONTROL: 

 

DATE OF PURCHASE: 

 

DEALER: 

 

INSTALLER:

 

Summary of Contents for RF-RF-LD30/36-VEI-N/P

Page 1: ...ed in an aftermarket permanently located manufactured mobile home where not prohibited by local codes This appliance is only for use with type of gas indicated on the rating plate INSTALLER Leave this...

Page 2: ...epair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning may be required due to exc...

Page 3: ...LD30 36 2 Rating I D Plate 3 Flex Connector SSCB 14 4 3 8 x 1 2 FIP Flared Brass Fitting A1 5 Orifice Spud see page 12 for size 6 Orifice Holder Internally Tapped 3 8 x 3 8 Flared MIP Fitting A2T 7 A...

Page 4: ...Switch Cable GV60 SWA 24 Module Receiver GV60 RXA 29 8 Wire Cable GV60 C8 25 Interrupter Block GV60 TIA 30 GV60 Battery Box Cable GV60 BCA 26 Ignition Cable GV60 ICA 31 Plug in Adapter for AC Power Su...

Page 5: ...and ventilation air must conform with The National Fuel Gas Code ANSI Z223 1 NFPA54 or The CSA B149 1 Natural Gas and Propane Installation Code latest edition STEP ONE PREPARATION 1 Verify that the Va...

Page 6: ...E REQUIREMENTS The minimum permanent free opening of the fireplace chimney or chimney damper must be at least the minimum Chimney Area shown below based on a minimum chimney height of at least 8 feet...

Page 7: ...propane gas burner A Natural Gas B Propane FIGURE 6 STEP TWO Sprinkle a light covering of Ember Magic over the Pan Medium Figure 6A and Figure 6B Pull apart Ember Magic fiber material to enhance the g...

Page 8: ...charred burnt effect between the two halves Figure 8 and Figure 9 Place the Longest Log or 2 largest charred logs if applicable Figure 8A and 9A as far forward on the Grate as possible The remaining l...

Page 9: ...ing BATTERY PACK PLACEMENT NOTE Any beeping or unexpected shutdown may be the over temperature safety feature in the receiver If this happens move the receiver into a cooler area and or use the RH2 RH...

Page 10: ...ROL SETTINGS ON GAS VALVE WHILE OPERATING WITH REMOTE TRANSMITTER Valve switch set to 0 Valve switch set to I VALVE IN 0N POSITION Valve switch set to I Flame height control knob turned 0N Flame heigh...

Page 11: ...beep release the reset button Within the subsequent 20 second press the small flame button on the handset until you hear two additional short beeps confirming the code is set If you hear one long bee...

Page 12: ...k pilot flame Weak pilot flame is the NUMBER 1 SERVICE ISSUE REGARDING NUISANCE SHUT OFF Using canned compressed air blow out the opposing air intake ports located at the base of the pilot where the g...

Page 13: ...l light properly The pilot flame should be steady and soft blue surrounding 1 8 inch of the thermocouple Pilot Tube Air Intake Port Thermocouple Tip Piezo Spark Blue Dot Natural Gas Red Dot Propane 1...

Page 14: ...which have been closed or are obstructed with debris will not allow sufficient combustion air into the burner Use compressed air and or a soft bristle brush to clean the air mixer area Air mixers sho...

Page 15: ...alve Vanisher Make sure the fireplace floor is even with the Hearth floor Also change batteries Odor and or Smoke After Break in Period other than Natural Odor of Gas Combustion Most likely causes Lac...

Page 16: ...The maximum liability of RASMUSSEN in connection with this limited warranty shall not in any case exceed the contract price paid for the product claimed to be defective or unsuitable 4 This warranty...

Reviews: