IMPORTANT INSTALLATION REQUIREMENTS
Required Minimum Permanent Chimney Damper Opening:
1.
The chimney damper must be fixed in a manner to maintain a permanent
free opening of at least 39 square inches based on a minimum chimney
height of at least 8 feet. The area of the flue must not be less than 1/10 the
area of the fireplace opening. The flue must exhaust all products of
combustion. MINIMUM PERMANENT CHIMNEY OPENING is
accomplished by either installing the provided damper clamp, permanently
fixing the damper open, or by drilling holes in the damper blade.
Attaching Damper Clamp:
1.
Install the damper clamp (provided) on the edge of the damper blade to
prevent its closing, or drill holes in the damper.
Damper
Stop Clamp
Damper
Chimney
Flue
.
WARNING: Minimum Permanent Chimney Damper Opening is the minimum permanent opening required
by Standard or Codes to ensure safe operation of the appliance. It is not the minimum operating damper
position. When operating this appliance, THE DAMPER MUST BE WIDE OPEN. The flue must
vent all products of combustion.
ASSEMBLY (Natural Gas Match Lighted Models Only)
WARNING: Match Lighted
L C ( 1 8 , 2 4 , 3 0 ) - N )
is for use with natural gas only. A safety pilot must be
installed on all units designed or converted to burn Propane/LP gas.
Required Tools And Materials:
Screw Driver, Adjustable Wrench, Pipe Wrench, Pipe Sealing Compound or Teflon Tape.
Natural Gas Match Lighted Model Assembly
1. Wrench tighten LOCKING PAL NUT (A) onto the non-flared end of 3/8"
ORIFICE HOLDER (B).
2. Thread ORIFICE SPUD (C) into 3/8" ORIFICE HOLDER (B) and tighten.
3. Apply pipe compound to the outside threads of the 3/8" ORIFICE HOLDER
( B ) . Thread into TOP BURNER TUBE (D). Wrench tighten with the flared
connection facing towards rear.
4. Insert RATING PLATE/HEAT SHIELD E) between the LOCKING
PALNUT (A) and BURNER TUBE (D). Wrench tighten LOCKING PAL NUT
B
C
A
D
E
Natural Gas Match Lighted Model with
Accessory V-17
(For use only with Natural Gas Models
LC (18,24,30)-N) Assembly
1.
Wrench tighten LOCKING PAL NUT (A) onto 3/8" ELBOW (B).
2.
Apply pipe compound to threaded end of 3/8" STREET EL (B). Thread into
TOP BURNER TUBE (C) and wrench tighten to position shown.
3.
Thread ORIFICE SPUD (D) into 3/8" V-17 VALVE (E) and wrench tighten.
4.
Apply pipe compound to orifice end of 3/8" V-17 VALVE (E). Thread into 3/8"
G
E
F
G
STREET EL (B) and wrench tighten to position shown.
5.
Apply pipe compound to inlet side threads of 3/8" V-17 VALVE
( E ) . Thread 3/8" CONNECTOR FITTING (F) onto inlet side of
3/8" V-17 VALVE (E) and wrench tighten.
6.
Insert the RATING PLATE-HEAT SHIELD (G) between the
LOCKING PAL NUT (A) and BURNER TUBE (D). Wrench
tighten the LOCKING PAL NUT.
7.
Insert K E Y ( G ) sleeve over 3/8" V-17 VALVE (E) stem.
Insert screw and tighten.
C
A
B
D
INSTALLATION (All Models)
Burner Pan and Grate Positioning (see Firebox Sizing Requirements-page 2):
REAR WALL
TOP VIEW
1. Place GRATE inside firebox as
far to the rear as possible. Center
GRATE left to right.
2. With open edge facing out, place
BURNER PAN beneath grate with
leading edge approximately one inch
forward of GRATE front legs.
3. Mark positions of GRATE and
BURNER PAN on fire place floor
with pencil. Remove from firebox.
SIDE VIEW
3