background image

WIRING 

8

L480 0216jlc                  

                      Specifications  Subject  to  Change  Without  Notice                                     Printed in U.S.A.

FOR LIMITED WARRANTY TERMS AND CONDITION PLEASE REFER TO TOILET MANUAL

FIG 5  

WIRING FOR SMART TOILET 

CONTROL WITH  MSD

PURASAN EX

FIG 6  

WIRING FOR SMART 

TOILET CONTROL WITH 

MSD

PURASAN EX

ELECTROSCAN

ELECTROSCAN

WALL SWITCH 

PANEL

BATT +

BATT -

SALT FD +

HEAD 1 +

HEAD 2 +

AUX +

NEG

NEG

NEG

NEG

MAN IN

EXT TRIG

EXT TRIG

MAN IN

HD NEG

FUSES

HD POS

EXT TRIG

TO MSD

16AWG

STC

SP

INLET+ BLUE

INLET - BLACK

FROM MSD

TO MSD

DISCH - BLACK

DISCH + RED

FLOAT

SENSALEVEL

COMMON

WHITE

BATT +

T1

T2

H1

M

AIR PU

MP+

AIR PU

MP-

DVAL

VE+

3

2

4

5

8

6

7

9

10

P

URAS

AN E

X

NEG

1

SPC

VALVE-

VALVE+

HOLDI

NG

TANK

WAL

L

 

SWITC

H

 

PAN

EL

RARI

T

AN

DISPEN

SER

T1

SALT FD +

HEAD 1 +

HEAD 2 +

AUX +

NEG

NEG

NEG

NEG

MAN IN

EXT TRIG

EXT TRIG

MAN IN

HD NEG

FUSES

HD POS

HEAD 1 +

FROM MSD

16 AWG

BATT +

T1

T2

H1

M

AIR PU

MP+

AIR PU

MP-

DVAL

VE+

3

2

4

5

8

6

7

9

10

P

URAS

AN E

X

NEG

1

SPC

VALVE-

VALVE+

HOLDI

NG

TANK

WAL

L

 

SWITC

H

 

PAN

EL

RARI

T

AN

DISPEN

SER

H1

WALL SWITCH 

PANEL

BATT +

BATT -

STC

SP

INLET+ BLUE

INLET - BLACK

FROM MSD

TO MSD

DISCH - BLACK

DISCH + RED

FLOAT

SENSALEVEL

COMMON

WHITE

530 Orange Street,  Millville, NJ  08332 USA
Telephone:   856-825-4900 

FAX:   856-825-4409  

www.raritaneng.com   

 

 

 

 

     

Fort Lauderdale, FL    

 

 

 

Telephone:   954-525-0378 

 

Summary of Contents for STC

Page 1: ...polarity protected In case of reverse polarity motors and solenoid will activate as soon as power is connected After reverse polarity is corrected within 10 minutes unit will work as normal 1 THE FOL...

Page 2: ...r three seconds The Holding Tank Full LED will flash THREE times indicating you have entered program mode 2 Push the WATER SAVER button once 3 Push the EMPTY ONLY button Flush mode will switch from Se...

Page 3: ...LY and EMPTY ONLY buttons Wall switch model only When in the factory default mode both the WATER ONLY and EMPTY ONLY buttons will only operate for maximum of eight seconds The procedure below will dis...

Page 4: ...unit and back to source 2 Distance from power source to remote intake pump MUST be included when determining total distance Same wire size MUST be used for lower base and remote intake pump 3 Recommen...

Page 5: ...fuse size amps Amp draw 10 feet 15 feet 20 feet 30 feet 40 feet 50 feet 12 VDC 25 18 10 AWG 10 AWG 8 AWG 6 AWG 6 AWG 4 AWG 24 VDC 15 10 16 AWG 16 AWG 14 AWG 12 AWG 10 AWG 10 AWG Units Voltage Circuit...

Page 6: ...breaker in positive line at source 4 Wire control to the toilet and battery using one of the following wiring diagrams To start Electroscan from toilet control run a wire from to MSD to terminal mark...

Page 7: ...SCH BLACK INLET BLUE INLET BLACK TO MSD WHITE SENSALEVEL COMMON FLOAT TOILET FLUSH CONTROL HOLDING TANK FULL WATER ONLY WATER SAVER EMPTY ONLY RARITAN NORMAL FLUSH SEA FRESH DISCHARGE PUMP BLACK 12AWG...

Page 8: ...ED FLOAT SENSALEVEL COMMON WHITE BATT T1 T2 H1 M AIR PUMP AIR PUMP DVALVE 3 2 4 5 8 6 7 9 10 PURASAN EX NEG 1 SPC VALVE VALVE HOLDING TANK WALL SWITCH PANEL RARITAN DISPENSER T1 SALT FD HEAD 1 HEAD 2...

Reviews: