background image

3

CONTROL SWITCH OPERATION:

Refer to  manual enclosed in control switch.

Winterizing:

• 

Improper winter lay up is a major cause of 

marine toilet failure.

• 

Use only nontoxic antifreeze.

• 

Flush toilet several times to clear waste from 

system.

• 

Dispose of all antifreeze in accordance with 

local and federal regulations.

• 

Winterize holding tanks, plumbing, treat

-

ment systems (MSD’s), etc. Independently 

following manufacturer’s instructions.

Pressurized Freshwater Models

Parts Required:

•  1" (25 mm.) Or 1 1/2" (38 mm.) I.D.  

discharge hose, approximately 3 feet (1 m.) 

long 

•  Two buckets 

•  Nontoxic antifreeze approximately 1 quart  

 

(1 liter)

Steps:

1.  Close discharge seacock (if one exists).

2.  Shut off intake water at source.

3.  Turn off power to unit.

4.  Disconnect and drain discharge hose.

5.  Disconnect intake hoses from water sole-

noid  and place in one of the buckets.

6.  Connect short hose to toilet’s discharge and 

place in other bucket.

7.  Pour antifreeze in bowl.

8.  Turn on power to unit and flush until anti

-

freeze is removed from the bowl and water is 

drained from the solenoid and hose.

9.  Disconnect power to toilet.

10.  Reconnect intake hoses to water solenoid.

Remote Intake Pump Model

Parts Required:

• 

3/4" (19 mm.) I.D. intake hose approximately 3 

feet (1 m.) long. 

•  1" (25 mm.) or 1 1/2" (38 mm.) I.D. discharge 

hose approximately 3 feet (1 m.) long. 

• 

Two buckets 

• 

Nontoxic antifreeze approximately 1 quart (1 

liter)

Steps:

1.  Close the intake and discharge seacocks.

2.  Turn off power to unit.

3.  Disconnect and drain intake hose and dis-

charge hose .

4.  Connect short  hoses to toilet’s intake and dis-

charge.

5.  Place one bucket under hose connected to 

toilet’s discharge.

6.  Pour nontoxic antifreeze in other bucket.

7.  Place hose connected to intake pump into 

bucket with antifreeze.

8.  Turn on power to unit and flush toilet until 

antifreeze begins to be discharged from toilet.

9.  Disconnect power from toilet.   

 

RECOMMISSIONING

1.  Using the buckets, hoses and approximately 

one gallon (3.8 liters) of clean fresh water, flush 

antifreeze out of the toilet (see Winterizing).  

Dispose of antifreeze in accordance with local 

and federal regulations.

2.  Reconnect the intake and discharge hoses and 

open both seacocks and water source valve.

3.  Check all connections for leaks with several 

test 

flushes.    

 

SYSTEM START-UP

1.  Open seacock(s).

NOTE:

  Pressurized freshwater models; open wa-

ter source valve.

2.  Turn on power to toilet.

3.  Flush toilet per operation instructions.

4.  Check for leaks.

   IMPORTANT:

 If toilet does not flush properly     

   or if water does not enter the bowl within 10      

   seconds, refer to troubleshooting.

WINTERIZING 

L365v0320jlc 

Summary of Contents for SeaEra QC 162

Page 1: ...ed in 46CFR 110 15 65 e Subchapter J Electrical Engineering DO NOT run continuously for more than 30 seconds WARNING HAZARD OF FLOODING Always shut off seacock s before leaving the boat unattended Dou...

Page 2: ...equirements No special toilet paper is required Water should appear in the bowl within ten seconds If not see troubleshooting section Hard objects or stringy substances paper towels feminine hygiene p...

Page 3: ...I D intake hose approximately 3 feet 1 m long 1 25 mm or 1 1 2 38 mm I D discharge hose approximately 3 feet 1 m long Two buckets Nontoxic antifreeze approximately 1 quart 1 liter Steps 1 Close the i...

Page 4: ...52 11 1 2 292 20 508 14 3 8 365 INCHES MM NOTE 1 THE SEAT WILL OPEN WITHIN THE DEPTH OF THE BOWL D HOWEVER IT MAY BE DESIRABLE TO INCREASE THIS ANGLE BY ALLOWING MORE ROOM AT THE BACK OF THE BOWL FOR...

Page 5: ...tal distance Same wire size MUST be used for lower base and remote intake pump 3 Recommended conductor wire minimum AWG mm2 for 3 voltage drop 4 Recommended conductor sizes are based on 105o C rated i...

Page 6: ...3 1 Determine which direction bowl is to be mounted 2 Remove four vinyl caps at the base of toilet bowl 3 Remove four nuts and shoulder washers 4 Carefully remove toilet bowl from base 5 Rotate toilet...

Page 7: ...nforced hoses Secure all hoses properly Pressurized Freshwater Model Installed Above Waterline SeaEra Toilet Discharge Holding Tank Pressurized Freshwater Source Waterline Shut off Valve 1 1 2 38mm Di...

Page 8: ...stalled Use hose clamp provided 7 Connect hose from outlet port of In Line Strainer to inlet port of intake pump Use hose clamp provided IMPORTANT Double clamp all below waterline hose connections 8 C...

Page 9: ...inconsistent voltage 1A Be sure discharge seacock is open Clear line remove clog 1B Replumb to eliminate bends and ells 1C Clean holding tank vent and vented loop vents 1D Clean or replace affected p...

Page 10: ...Fitting 51 190601 Inline Fresh Water Strainer Optional 61 163000 Inline Strainer Optional SeaEra QC model 162 PARTS LIST Additional Parts Included with REMOTE MODELS Item Part Description 27 161135 M...

Page 11: ...11 EXPLODED PARTS SeaEra QC Series Exploded Parts View Optional Sea Water Strainer Optional Fresh Water Strainer L365v0320jlc 84...

Page 12: ...installation of this product defects caused by installation of this product otherthaninaccordancewiththemanufacturer srecommendedinstallationinstructionsorstandard industry procedures physical abuse t...

Reviews: