Parts Included in the Box:

Control Module

16’ of Cable to 

Connect Switch 

Panel to Control 

Box

Air Pump

For Dispenser:

   6’ 

1

/

4

” ID tubing

    6’ 3/8” ID tubing

For Treatment unit:

6’ 

3

/

8

” ID tubing

Switch Panel Switch Panel 

Gasket

Tablet 

Dispenser

Inside the module:

 Drain Manifold  

 Water Valve

 SPC control box

6’ black and orange 

wire to connect tank

Fittings for 

Treatment 

Unit

Treatment unit

SensaLevel

sensor with 

cable

6’ black and red

wire to connect 

transfer pump

L519 _0815jlc 

Summary of Contents for Purasan PST12EX

Page 1: ...personnel that may result from improper installation or operation of this product WARNING HAZARD OF SHOCK AND FIRE Always use recommended fuse or circuit breaker and wire size WARNING HAZARD OF FLOOD...

Page 2: ...ing tank is above the LOW LEVEL treatment cycle starts Macerator pump is activated and moves approximately 1 gallon of waste from the holding tank to the treatment tank Treatment cycles runs for 2 min...

Page 3: ...cle completes normal there is a 8 second pause before next cycle will start During this pause none of the buttons except No Discharge mode button is functional MAINTENANCE CAUTION Do not load tablets...

Page 4: ...nstructions in the Owner s Manual for that particular toilet Recommissioning IMPORTANT Do not open shut off valve feeding control module until Treatment Tank is full Do not operate PURASAN EX until Tr...

Page 5: ...er Size with macerator pump Fuse Specifications 3 1 4 8 3 cm 4 3 4 12 cm SWITCH PANEL DIMENSIONS Depth 8 22 3cm Width 16 40 6cm TREATMENT UNIT DIMENSIONS Height 13 34 3cm TABLET DISPENSER DIMENSIONS F...

Page 6: ...ubing 6 3 8 ID tubing For Treatment unit 6 3 8 ID tubing Switch Panel Switch Panel Gasket Tablet Dispenser Inside the module Drain Manifold Water Valve SPC control box 6 black and orange wire to conne...

Page 7: ...e wall FIG 6 Switch Panel Cable Supplied is 16 feet 1 Locate in head compartment where indicator lights will be visible 2 Using base plate mark the cutout for the panel See FIG 7 3 Route cable between...

Page 8: ...or nonpermanent thread sealing compound on threaded PVC fittings and connections Avoid low areas in hose that would allow untreated waste to collect 1 Connect discharge of macerator to one intake port...

Page 9: ...le from Tablet Dispenser to Control module Using cable clamp secure cable on the wall near dispenser 2 Connect sensor cable to control module SPC Note Complete programming for Fill and Empty timing be...

Page 10: ...R NO DISCHARGE TREATMENT RARITAN KEY SWITCH OPTIONAL SEA COCK OPTIONAL SensaLevelTM BLACK WHITE OR RED BLACK WATER SOLENOID AIR PUMP DRAIN MAINIFOLD NEG POS 3 AMP FUSE TO POS TERMINAL BLACK 12AWG RED...

Page 11: ...conds recorded in step 3 Note maximum is 20 and minimum is 2 Push the START STOP button to store this value the unit will flash three times indicating the time has been set and you have left program m...

Page 12: ...11 17 18 8 7 2 3 62 1 62 26 25 56 52 51 22 57 48 47 46 45 44 43 40 41 70 71 80 81 85 84 86 82 83 72 27 39 37 38 36 32 54 53 36 31 30 58 41 137W 221351W 12V 221352W 24V 41 100AW 162000WA SPC 59 66 65...

Page 13: ...shing 2 31 105 O Ring 31 106 10 32x 7 8 Screws 4 31 112 Cover Gasket DRAIN MANIFOLD ASSEMBLY 41 137W 24 41 151A Adapter 1 4 x 1 2 elbow with check valve 27 41 145 Pull Solenoid 28 41 137 Drain Manifol...

Page 14: ...are programmable Total treatment time is 120 seconds FILL CYCLE HOLD CYCLE EMPTY CYCLE DRAIN MANIFOLD PORTS Fig13 Water in Fill Air in Air to disp Empty To tank CHECK VALVE SYMBOL Location of Compone...

Page 15: ...tablet dispenser Press empty button to run air pump and clear any clog Clogged Check valve treatment tank adapter Clean or replace check valve 41 170 located on the tank Water fill time not programme...

Page 16: ...SPECIAL OR CONSE QUENTIALDAMAGES WHETHERARISING OUT OF BREACH OF WARRANTY BREACH OF CONTRACT OR OTHERWISE SOME STATES DO NOTALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO...

Reviews: