background image

13

EXPLODED P

ARTS

PURASAN PARTS LIST

*NOTE:  12VDC units are equipped with a 24VDC 
Macerator Motor, 24VDC units are equipped with a 
32VDC Macerator Motor.

**NOTE: All models use a 24VDC Motor

Item  Part # 

Description  

  1  32-102AW  Mixer Motor 2 1/2” Dia. 12 V DC

  1  33-102AW  Mixer Motor 2 1/2” Dia. 24 VDC 

    (1) includes shaft seals and bushing for mixer motor)

  2  31-121 

Hose Fitting (2)

(Not shown) 

 90

)0 

hose fitting (PLA401)

  3  31-120 

Discharge Elbow 90

o

  6  31-134 

Cover Hold down Bolt, 10-32 x 1” (16)

(not shown)

  7  31-103 

Motor Shaft Bushing (2) (see 62)

  8  31-106 

Motor Hold down Bolt, 10-32x1”, S/S (4)

  9  31-109 

Mixer Impeller

10  31-110-1 

Impeller Bolt, 12-24 x 5/8”, S/S (2)

11  31-110-2 

Impeller Lock Washer, #12, S/S (2)

12  31-114 

Cover Hold down Nut, 10-32 (18)

13  31-115PS 

Treatment Tank

14  31-122  

Intake Plug

15  41-102 

Tank Divider

16  31-112 

Cover Gasket

17  31-108 

Macerator Set Screw

18  31-107 

Macerator Impeller

19  41-101W 

Treatment Cover (includes 62,56, 25,26)

22  33-101AW*  Macerator Motor  for 12 V DC unit

22  34-101AW*  Macerator Motor for  24 V DC

 (22)  includes shaft seal and bushing for Macerator motor

25  31-104CW  Crossover Plug with O-ring

26  31-105 

O-Ring 

51  M31 

#14 Brass Flat Washer (4)

52  M30 

1/4”-20 Brass Nut (4)

56  31-325A 

Adapter Tank Lid

57      221335 

Hose

58  41-170     

Tank check valve      

59      31-304C         Hose clamp

62      ESTRK          EST/PST Repair Kit includes following

 

(Not Shown)  31-102 Motor Shaft Seal(2)

 

 

31-102-1 Macerator Seal Washer

 

 

31-102-2 Macerator Retaining Ring

 

 

31-102-3 Mixer Seal Washer

 

 

31-102-4  Mixer Retaining Ring

 

 

31-103 Motor Shaft Bushing(2)

 

 

31-105  O-Ring 

 

 

31-106   10-32x 7/8” Screws (4)

 

 

31-112   Cover Gasket

DRAIN MANIFOLD ASSEMBLY(41-137W)

24  41-151A 

Adapter 

1

/

4

” x 

1

/

2

” elbow with check valve

27      41-145 

Pull Solenoid

28  41-137 

Drain Manifold assy.(with check valve)

29   41-151B 

Adapter 

1

/

8

” x 

1

/

4

” elbow with check valve

30  41-141   

1

/

4

” NPT x 1/2” barbed adapter

31      PLA3 

1

/

4

” Barbed x 

1

/

4

” NPT Adapter

32      41-139            Cap, manifold

33      41-138C          

1

/

4

” x 

3

/

4

” U cup seal

34  41-138 B          Plunger

35      41-138A          Washer for plunger

36      F204                6-32 x 3/8”” Flat head mach. screw(4)

37      LWS              Spring

38      F203              Washer 5/16” x 3/4”

39      F233       

Spring Roll Pin

50  41-187 

Shaft Boot 

 

 

53    41-152 

Base Plate

54  F232 

6-32 x 7/16” Flat head mach. screw (2)

55  F231 

Spacer  6” x 5/32” 

 

 

 

TABLET DISPENSER (41-100AW)

40  41-130A 

Dispenser Body.

41  41-177 

Adapter 1/2”NPT  x 1/2” barb

43      41-156W 

Tablet holder assembly.

44      41-135A 

Purasan Tablets (sold saparately)

45      41-179          Float extension pipe

46  41-178W  

Float sensor

47  RWS5A 

“O” Ring

48  41-131M 

Dispenser Cap (machined)

85  41-505          Cable for Float sensor   

 

WATER  Valve (221351W, 12V - 221352W, 24V) 

65  221356W       Inlet hose adapter 

66  PX50W 

Double Check Valve assembly

67  221351 

Water Solenoid 12V

67      221352           Water Solenoid 24V

68      221335           1/2” Hose

69      41-157            Metering washer

AIR PUMP for tablet dispenser (162000WA)
70      166024A **   Motor 
71      162000W       Intake Pump Assembly,air pump
72       162415A       Plug with barbed fitting

 

DIAPUMPRK    Diaphragm Pump Repair Kit

CONTROLS

80      SPCCHNT  Purasan Control 
81       41-502          Wall Panel circuit board 
82       221514         ME: wall panel cover,white
83       221525         ME; wall panel gasket           
84  31-618          Cable for SPC  wall panel
86      FUSE10        ATO fuse 10A

  OTHER (Not shown)

 

41-135A     Purasan Tablets (Refill)

 

42-1000A      Treatment Unit Complete 12V

 

43-1000A      Treatment Unit Complete 24V

 

 

L519 _0815jlc 

Summary of Contents for Purasan PST12EX

Page 1: ...personnel that may result from improper installation or operation of this product WARNING HAZARD OF SHOCK AND FIRE Always use recommended fuse or circuit breaker and wire size WARNING HAZARD OF FLOOD...

Page 2: ...ing tank is above the LOW LEVEL treatment cycle starts Macerator pump is activated and moves approximately 1 gallon of waste from the holding tank to the treatment tank Treatment cycles runs for 2 min...

Page 3: ...cle completes normal there is a 8 second pause before next cycle will start During this pause none of the buttons except No Discharge mode button is functional MAINTENANCE CAUTION Do not load tablets...

Page 4: ...nstructions in the Owner s Manual for that particular toilet Recommissioning IMPORTANT Do not open shut off valve feeding control module until Treatment Tank is full Do not operate PURASAN EX until Tr...

Page 5: ...er Size with macerator pump Fuse Specifications 3 1 4 8 3 cm 4 3 4 12 cm SWITCH PANEL DIMENSIONS Depth 8 22 3cm Width 16 40 6cm TREATMENT UNIT DIMENSIONS Height 13 34 3cm TABLET DISPENSER DIMENSIONS F...

Page 6: ...ubing 6 3 8 ID tubing For Treatment unit 6 3 8 ID tubing Switch Panel Switch Panel Gasket Tablet Dispenser Inside the module Drain Manifold Water Valve SPC control box 6 black and orange wire to conne...

Page 7: ...e wall FIG 6 Switch Panel Cable Supplied is 16 feet 1 Locate in head compartment where indicator lights will be visible 2 Using base plate mark the cutout for the panel See FIG 7 3 Route cable between...

Page 8: ...or nonpermanent thread sealing compound on threaded PVC fittings and connections Avoid low areas in hose that would allow untreated waste to collect 1 Connect discharge of macerator to one intake port...

Page 9: ...le from Tablet Dispenser to Control module Using cable clamp secure cable on the wall near dispenser 2 Connect sensor cable to control module SPC Note Complete programming for Fill and Empty timing be...

Page 10: ...R NO DISCHARGE TREATMENT RARITAN KEY SWITCH OPTIONAL SEA COCK OPTIONAL SensaLevelTM BLACK WHITE OR RED BLACK WATER SOLENOID AIR PUMP DRAIN MAINIFOLD NEG POS 3 AMP FUSE TO POS TERMINAL BLACK 12AWG RED...

Page 11: ...conds recorded in step 3 Note maximum is 20 and minimum is 2 Push the START STOP button to store this value the unit will flash three times indicating the time has been set and you have left program m...

Page 12: ...11 17 18 8 7 2 3 62 1 62 26 25 56 52 51 22 57 48 47 46 45 44 43 40 41 70 71 80 81 85 84 86 82 83 72 27 39 37 38 36 32 54 53 36 31 30 58 41 137W 221351W 12V 221352W 24V 41 100AW 162000WA SPC 59 66 65...

Page 13: ...shing 2 31 105 O Ring 31 106 10 32x 7 8 Screws 4 31 112 Cover Gasket DRAIN MANIFOLD ASSEMBLY 41 137W 24 41 151A Adapter 1 4 x 1 2 elbow with check valve 27 41 145 Pull Solenoid 28 41 137 Drain Manifol...

Page 14: ...are programmable Total treatment time is 120 seconds FILL CYCLE HOLD CYCLE EMPTY CYCLE DRAIN MANIFOLD PORTS Fig13 Water in Fill Air in Air to disp Empty To tank CHECK VALVE SYMBOL Location of Compone...

Page 15: ...tablet dispenser Press empty button to run air pump and clear any clog Clogged Check valve treatment tank adapter Clean or replace check valve 41 170 located on the tank Water fill time not programme...

Page 16: ...SPECIAL OR CONSE QUENTIALDAMAGES WHETHERARISING OUT OF BREACH OF WARRANTY BREACH OF CONTRACT OR OTHERWISE SOME STATES DO NOTALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO...