11
INITIAL SETTING OF “FILL” and “EMPTY”
Must be completed during installation to be sure water
reaches level mark on dispenser.
1.
All settings should be done with water source (on
board pressure pump or shore water supply) that will
be used with PURASAN. Settings done will only
be valid for that source, and may need to be repro
-
grammed if another source is utilized. Lid must be
closed tight during setting and use.
2.
Dispenser must not contain tablets during initial
set-up. Program “fill” time without tablet to reach
1/4” below top marked lines, Unplug sensor cable at
Control Module.
3. With power on, press “fill “and count seconds un
-
til water reaches to water level mark on dispenser.
Record seconds as fill. If recorded seconds are greater
than 18 , Open the hole to approx 1/8” in metering
washer between water valve (221352) and check valve
(PX50W) and repeat.
4. Empty water below tablet dispenser bottom and entire
3/8” tube till treatment tank while pressing “empty”
button and counting seconds. Record seconds as
empty
5. SET PRELIMINARY “FILL” time:
• Hold the EMPTY & FILL buttons down together for
three seconds. The error LED will give three quick
flashes indicating you have entered program mode -
release both buttons.
• Press “FILL “ button as many times as fill seconds
recorded in step 2. example: 8 seconds press 8 times.
Note: maximum is 20 and minimum is 2.
• Push the “START/STOP” button to store this value
(the unit will flash three times indicating the time has
been set and you have left program mode).
6. SET PRELIMINARY “EMPTY” time:
• Hold the EMPTY & FILL buttons down together for
three seconds. The error LED will give three quick
flashes indicating you have entered program mode -
release both buttons.
• Press “EMPTY “ button as many times as empty
seconds recorded in step 4.
Note:
Minimum time is set at 10 seconds. Each press
of the EMPTY button will add 1 second to minimum
time. Maximum is 20 seconds.
• Push the “START/STOP” button to store this value
(the unit will flash three times indicating the time has
been set and you have left program mode).
Macerator
Pump
FIG 11
FILL
EMPTY
ERROR
Treatment
PROGRAMMING
After hold time, air pump and drain valve will drain
solution. Make sure that water is drained from entire
tube up to treatment tank. Increase empty time using
step 6 if drain time is not sufficient. After drain cycle,
air pump and water solenoid will stay on for 10 more
seconds (non-programmable). This will flush the check
valve near the tank. Repeat flush cycle to check fill time.
If water level is not filling up between lines, increase or
decrease fill time using steps 2 thru 6.
NOTE:
The cycle after the drain cycle can be stopped
by pressing start/stop button at any time.
With Tablets:
Follow start up procedure. Load tablets
and plug sensor cable. Press “START/STOP” button.
The water should fill up between level line. Make final
adjustment as per above instructions if needed.
L519 _0919jlc
7. TEST SETTINGS:
Without Tablets:
Press start/stop button. Water should
fill up in the dispenser at least up to lower line but no
higher than half way between line. Hold time of water
is 20 seconds and not programmable.
Setting of Transfer/macerator pump on time:
NOTE:
Pump time is set to 10 seconds as shipped.
• Hold the EMPTY & FILL buttons down together for
three seconds. The error LED will give three quick
flashes indicating you have entered program mode -
release both buttons.
• Press No Discharge button (FIG 11, next to start/stop
button) as many times as needed to set pump time
(One push = 1 sec’s, two= 2 sec’s, three= 3 sec’s
etc.). The LED will flash once indicating a valid key
push.
NOTE:
Maximum is 20 seconds.
• Push the START/STOP button to store this value
(the unit will flash three times indicating the time has
been set and you have left program mode).
NOTE:
When the waste/water level in the tank is high
enough to activate the treatment cycle and it is in a treat
-
ment cycle, the time settings for FILL, EMPTY and/or
Transfer/ Macerator Pump can be adjusted by:
• Press START/STOP button
• Within 8 seconds of pressing the Start/Stop button,
proceed with reprogramming as instructed. After the
Start/Stop button is pressed, the treatment cycle
should begin after several seconds. If further
adjustments are needed, repeat process.