INITIAL SETTING OF “FILL” and  “EMPTY”

 

Must be completed during installation to be sure water 

reaches level mark on dispenser.

1.   

  All settings should be done with water source (on 

board pressure pump or shore water supply) that will 

be used with PURASAN. Settings done will only 

be valid for that source, and may need to be repro

-

grammed if another source is utilized. Lid must be 

closed tight during setting and use.

2.

   Dispenser must not contain tablets during initial 

set-up. Program “fill” time without tablet to reach 

1/4” below top marked lines, Unplug sensor cable at 

Control Module.

3.   With power on, press “fill “and count seconds un

-

til water reaches to water level mark on dispenser. 

Record seconds as fill. If recorded seconds are greater 

than 18 , Open the hole to approx 1/8” in  metering 

washer between water valve (221352) and check valve 

(PX50W) and repeat.

4.    Empty water below tablet dispenser bottom and entire 

3/8” tube  till treatment tank while pressing “empty” 

button and counting seconds. Record seconds as 

empty

5. SET PRELIMINARY “FILL” time: 

•  Hold the EMPTY & FILL buttons down together for 

three seconds.  The error  LED will give three quick 

flashes indicating you have entered program mode - 

release both buttons.

•  Press “FILL “ button as many times as fill seconds 

recorded in step 2. example:  8 seconds press 8 times. 

Note: maximum is 20  and minimum is 2.

•  Push the “START/STOP” button to store this value 

(the unit will flash three times indicating the time has 

been set and you have left program mode).

6. SET PRELIMINARY “EMPTY” time:

 

•  Hold the EMPTY & FILL buttons down together for 

three seconds.  The error  LED will give three quick 

flashes indicating you have entered program mode - 

release both buttons.

•  Press “EMPTY “ button as many times as empty 

seconds recorded in step 4.  

 

 

Note:

 Minimum time is set at 10 seconds. Each press 

of the EMPTY button will add 1 second to minimum 

time. Maximum is 20 seconds. 

•  Push the “START/STOP” button to store this value 

(the unit will flash three times indicating the time has 

been set and you have left program mode).

Macerator 

Pump

FIG 11

FILL

EMPTY

ERROR

Treatment

PROGRAMMING

After hold time, air pump and drain valve will drain 

solution. Make sure that water is drained from entire 

tube up to treatment tank. Increase empty time using 

step 6 if drain time is not sufficient. After drain cycle, 

air pump and water solenoid will stay on for 10 more 

seconds (non-programmable). This will flush the check 

valve near the tank. Repeat flush cycle to check fill time. 

If water level is not filling up between lines, increase or 

decrease fill time using steps 2 thru 6.

NOTE:

 The cycle after the drain cycle can be stopped 

by pressing start/stop button at any time.

With Tablets:  

Follow start up procedure. Load tablets 

and plug sensor cable. Press “START/STOP” button. 

The water should fill up between level line. Make final 

adjustment as per above instructions if needed.

L519 _0919jlc 

7. TEST SETTINGS: 

         Without Tablets: 

Press start/stop button. Water should  

          fill up in the dispenser at least up to lower line but no   

          higher than half way between line. Hold time of water  

          is 20 seconds and not programmable. 

Setting of Transfer/macerator pump on time:

NOTE:

 Pump time is set to 10 seconds as shipped.

•  Hold the EMPTY & FILL buttons down together for 

three seconds.  The error  LED will give three quick 

flashes indicating you have entered program mode - 

release both buttons.

•     Press No Discharge button (FIG 11, next to start/stop

      button) as many times as needed to set pump time  

      (One push = 1 sec’s, two= 2 sec’s, three= 3 sec’s                   

      etc.). The LED will flash once indicating a valid key   

      push.  

NOTE:

 Maximum is 20 seconds. 

•  Push the START/STOP button to store this value 

(the unit will flash three times indicating the time has 

been set and you have left program mode). 

NOTE: 

When the waste/water level in the tank is high 

enough to activate the treatment cycle and it is in a treat

-

ment cycle, the time settings for FILL, EMPTY and/or 

Transfer/ Macerator Pump can be adjusted by:   

•     Press START/STOP button  

•     Within 8 seconds of pressing the Start/Stop button,          

      proceed with reprogramming as instructed. After the          

      Start/Stop button is pressed, the treatment cycle

      should begin after several seconds. If further              

      adjustments are needed, repeat process. 

Summary of Contents for PURASAN EX Hold n' Treat

Page 1: ...o personnel that may result from improper installation or operation of this product WARNING HAZARD OF SHOCK AND FIRE Always use recommended fuse or circuit breaker and wire size WARNING HAZARD OF FLOO...

Page 2: ...lding tank is above the LOW LEVEL treatment cycle starts Macerator pump is activated and moves approximately 1 gallon of waste from the holding tank to the treatment tank Treatment cycles runs for 2 m...

Page 3: ...level 3 If cycle completes normal there is a 8 second pause before next cycle will start During this pause none of the buttons except No Discharge mode button is functional MAINTENANCE CAUTION Do not...

Page 4: ...nstructions in the Owner s Manual for that particular toilet Recommissioning IMPORTANT Do not open shut off valve feeding control module until Treatment Tank is full Do not operate PURASAN EX until Tr...

Page 5: ...er Size with macerator pump Fuse Specifications 3 1 4 8 3 cm 4 3 4 12 cm SWITCH PANEL DIMENSIONS Depth 8 22 3cm Width 16 40 6cm TREATMENT UNIT DIMENSIONS Height 13 34 3cm TABLET DISPENSER DIMENSIONS F...

Page 6: ...ubing 6 3 8 ID tubing For Treatment unit 6 3 8 ID tubing Switch Panel Switch Panel Gasket Tablet Dispenser Inside the module Drain Manifold Water Valve SPC control box 6 black and orange wire to conne...

Page 7: ...e wall FIG 6 Switch Panel Cable Supplied is 16 feet 1 Locate in head compartment where indicator lights will be visible 2 Using base plate mark the cutout for the panel See FIG 7 3 Route cable between...

Page 8: ...FE tape or nonpermanent thread sealing compound on threaded PVC fittings and connections Avoid low areas in hose that would allow untreated waste to collect 1 Connect discharge of macerator to one int...

Page 9: ...odule Using cable clamp secure cable on the wall near dispenser 2 Connect sensor cable to control module SPC Note Complete programming for Fill and Empty timing before connecting shutoff valve key swi...

Page 10: ...PTIONAL SensaLevelTM BLACK WHITE OR RED BLACK WATER SOLENOID AIR PUMP DRAIN MAINIFOLD NEG POS 3 AMP FUSE TO POS TERMINAL BLACK 12AWG RED 12AWG BLUE BLACK RED CABLE CABLE RED 86 30 87 85 FUSE 25 AMP 12...

Page 11: ...you have left program mode Macerator Pump FIG 11 FILL EMPTY ERROR Treatment PROGRAMMING After hold time air pump and drain valve will drain solution Make sure that water is drained from entire tube u...

Page 12: ...1 22 57 48 47 46 45 44 43 40 41 70 71 80 81 85 84 86 82 83 72 27 39 37 38 36 32 54 53 36 31 30 58 41 137W 221351W 12V 221352W 24V 41 100AW 162000WA SPC 59 66 64 67 68 69 28 29 24 33 34 35 50 55 65 L51...

Page 13: ...seal 34 41 138 B Plunger 35 41 138A Washer for plunger 36 F204 6 32 x 3 8 Flat head mach screw 4 37 LWS Spring 38 F203 Washer 5 16 x 3 4 39 F233 Spring Roll Pin 50 41 187 Shaft Boot 53 41 152 Base Pla...

Page 14: ...QUENCE Note Fill time and Empty times are programmable Total treatment time is 120 seconds FILL CYCLE HOLD CYCLE EMPTY CYCLE DRAIN MANIFOLD PORTS Fig13 Water in Fill Air in Air to disp Empty To tank C...

Page 15: ...tablet dispenser Press empty button to run air pump and clear any clog Clogged Check valve treatment tank adapter Clean or replace check valve 41 170 located on the tank Water fill time not programme...

Page 16: ...HER PERSONS FOR ANY SPECIAL OR CONSE QUENTIALDAMAGES WHETHERARISING OUT OF BREACH OF WARRANTY BREACH OF CONTRACT OR OTHERWISE SOME STATES DO NOTALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSE...

Reviews: