WIRING

WIRING

WARNING:  Hazard of Shock and Fire

•  Always use proper wire, wire connectors 

and fuse/circuit breaker.  See Specification 

Chart.

•  Secure wire properly.

•  Do not connect appliances to toilet circuit.

•  Make sure power is off before proceeding.

•  Use  proper  wire  terminals  for  all  wire 

connections.

1.  Determine proper wire size by measuring 

distance from:

  •  Power Source to push button to toilet motor 

and back to power source.

  •  Remote pump units - also include distance 

from power source for remote pump to 

remote pump and back.  Same wire gauge 

must be used for both lower base and 

remote pump.

2.  Select proper wire and fuse/circuit breaker 

size from Specifications on Installation page.

3.  Install fuse/circuit breaker in positive line at 

source.

4.  Wire control to the toilet and battery using 

one of the wiring diagram supplied with the 

control.

 Mounting  controls:

Refer to instruction enclosed with control.

Install the Warning Label (L322) where it can 

be easily seen.

5.    Route wire from  control per wiring 

diagrams.

6.    Install seat. Install discharge support strap 

between seat nut and the bowl (FIG 10).

Caution: To avoid kinking, do not pull on the

discharge hose. Be certain there is no pressure on

the discharge line.

7.     Install mounting bushings, bolts. (FIG 11)

8.    Tighten bolts being careful to not overtighten 

(Do not exceed 30 inch lb. when tightening)

9.    Install caps over mounting bolts.

Connect Hoses and wiring to toilet

Mount toilet

FIG 10

FIG 11

L490  0720jlc                                                                                                             

Summary of Contents for Marine Elegance Toilet

Page 1: ...Wireless Remote Bluetooth Control program your STC wirelessly up to 50 ft away from the toilet Eliminates the need to route wires through bulkheads and cabinetry Marine Elegance THE FOLLOWING ARE CAUT...

Page 2: ...d connections In Line Strainer if you have one No special toilet paper is required Water should appear in the bowl within ten seconds If not see troubleshooting section Hard objects or stringy substan...

Page 3: ...1 2 38 mm I D discharge hose approximately 3 feet 1 m long Two buckets Nontoxic antifreeze approximately 1 quart 1 liter Steps 1 Close the intake and discharge seacocks 2 Turn off power to unit 3 Dis...

Page 4: ...ce Same wire size MUST be used for lower base and remote intake pump 3 Recommended conductor wire minimum AWG mm2 for 3 voltage drop 4 Recommended conductor sizes are based on 105o C rated insulation...

Page 5: ...les center line and outside of the bowl FIG 1 Draw a center line between two holes Mark front hole outside and center and draw a line perpendicular to first center line 2 Mark three lines A B and C 3...

Page 6: ...aterline Discharge Pressurized Fresh water Source Shut off Valve Waterline remote pump Electroscan Waterline Discharge Seacock Waterline Discharge Vented Loop Intake Vented Loop Discharge Seacock Inta...

Page 7: ...ank etc Inlet Lines 1 Connect 1 2 13 mm hose to pressurized supply or 3 4 19 mm hose to remote pump Intake Lines Pressurized Freshwater Models 1 Install a shut off valve in intake line before water so...

Page 8: ...it breaker size from Specifications on Installation page 3 Install fuse circuit breaker in positive line at source 4 Wire control to the toilet and battery using one of the wiring diagram supplied wit...

Page 9: ...ak from bowl spud TROUBLESHOOTING SOLUTION 1A Be sure discharge seacock is open Clear line remove clog 1B Replumb to eliminate bends and ells 1C Clean holding tank vent and vented loop vents 1D Clean...

Page 10: ...44 162415 Plug Fitting 45 162420 Fitting Retaining Clip 3 46 162425 O ring 3 47 F162VT Inlet Pump Mounting Bolt 4 48 F144 10 Washer SS Flat 4 50 PLA26 Elbow Adapter 3 4 X 1 2 PRESSURIZED FRESH WATER U...

Page 11: ...11 EXPLODED PARTS L490 0720jlc...

Page 12: ...n instructions or standard industry procedures physical abuse to or misuse of this product This warranty also does not cover damages to equipment caused by fire flood external water excessive corrosio...

Reviews: