6
PLUMBING
PLUMBING
WARNING: HAZARD OF FLOODING
Toilets mounted at or below the waterline, at
greatest angle of heel, and connected to a Seacock/
Thru Hull Fitting(s) MUST have VENTED LOOPS
installed in toilet discharge plumbing and between
raw water intake pump and toilet bowl.
Install vented loops per manufacturer’s instructions.
Sea Water Models installed below the waterline
MUST have a vented loop installed between the
intake pump and the toilet bowl.
Double clamp all below-waterline connections.
IMPORTANT
• Fittings and 90° bends should be kept to a
minimum.
• In-Line Strainer may be installed on Sea
Water Models per Installation Instructions.
This will prevent clogs.
• Discharging untreated sewage is forbidden in
all U. S. waters within the three-mile limit.
• Thru-hull fittings and seacocks must be
installed where they are easily accessible.
• Use only quality reinforced hoses such as
Raritan Saniflex (SFH)
• Secure all hoses properly.
Waterline
Pressurized Freshwater Model Installed
Above/below Waterline
Discharge
Pressurized Fresh-
water
Source
Shut off Valve
Waterline
remote pump
Electroscan
Waterline
Discharge Seacock
Waterline
Discharge Vented
Loop
Intake Vented Loop
Discharge
Seacock
Intake Seacock
Electroscan
Pressurized Freshwater Model Installed
below Waterline
Holding Tank
Residual Water in the Bowl
The Marine Elegance is equipped with an
integral vent to maintain water in the bowl when
the plumbing lines are routed downward
(See FIG 4a and FIG 4b).
The Smart Toilet Control (STC) is designed to
add water at the end of the flush cycle. The toilet
will not hold more than about 4” in the bowl.
If any of the discharge hose runs higher than
the internal integral vent, DO NOT REMOVE
THE VENT CAP. For vent to work properly
in downward installation, the vent cap must be
removed (see FIG 5).
Remote Intake Pump Model Mounted
below Waterline
To enable vent, remove Vent Cap (FIG 5).
Toilet Installed above waterline
or above Treatment Device and
or Holding Tank = Downward
discharge flow
Remove vent cap
Toilet installed below waterline
or below Treatment Device
and or holding Tank = Upward
discharge flow
Do not remove vent cap
FIG 3a
FIG 4a
FIG 5
L490 0720jlc
Vent Cap
FIG 3b
FIG 3c
FIG 4b
Summary of Contents for Marine Elegance Toilet