Pressurized Freshwater Model - Recommended Wire and Fuse/Circuit Breaker Size

Sea Water Model - Recommended Wire and Fuse/Circuit Breaker Size

Plumbing

NOTES: for Wiring

Hose Sizes

INLET

 

1/2”(12.7 mm.)  for freshwater model

 

3/4” (19 mm.) for sea water model

Discharge

 

1”(25.4 mm.)  or 1  1/2”(38 mm.) 

CONVERSIONS

Wire - AWG to mm

2

Feet to Meters

AWG

16

14

12

10

8

6

4

2

mm

2

1.5

2.5

4.0

6.0

10.0 16.0 25.0 35.0

Feet

10

15

20

25

30

40

50

Meter

3.1

4.6

6.1

7.6

9.2

12.2 15.2

1.

Distances are from source to unit and back to source.

2.

Distance from power source to remote intake pump MUST be included when

determining total distance.Same wire size MUST be used for lower base and

remote intake pump.

3.

Recommended conductor wire minimum AWG (mm

2

) for 3% voltage drop.

4.

Recommended conductor sizes are based on 105

o

C rated insulation.

Refer to ABYC Standards for other insulation ratings.

5.

For 120/240 VAC units use 12VDC specifications from transformer to unit.

Maximum  suction  of  Intake  Pump                             

(Maximum height above waterline)

4 ft (1.2m) from Intake Pump

Maximum height of discharge vented 

loop

10 ft (3 m) from base of toilet

Pressurized water source minimum         

requirements

Minimum flow rate 5 gallons      

(19 liters) per minute. Minimum 

pressure 5 PSI (34.5 KPA)

Units       

Voltage

Circuit 

Breaker/

fuse size 

(amps)

Toilet 

Discharge 

Amps draw

Remote 

Pump Only 

Amp draw

                           

10 feet

              

15 feet

                    

20 feet

                     

30 feet

                    

40 feet

                   

50 feet

12 VDC

30

18

10

10 AWG

8 AWG

6 AWG

4 AWG

4 AWG

2 AWG

24 VDC

20

10

5

16 AWG

14 AWG

12 AWG

10 AWG

10 AWG

8 AWG

Units    

Voltage

Circuit 

Breaker/fuse 

size (amps)

Amp draw

10 feet

15 feet

20 feet

30 feet

40 feet

50 feet

12 VDC

25

18

10 AWG

10 AWG

8 AWG

6 AWG

6 AWG

4 AWG

24 VDC

15

10

16 AWG

16 AWG

14 AWG

12 AWG

10 AWG

10 AWG

L442  1221jlc                                                                                                             

10

1
4

 [260]

14

1
2

 [368]

INCH

[MM]

16

1
2

 [419]

18

1
2

 [470]

16

1
2

 [420]

21

5
8

 [549]

Atlantes discharge Maximum recommended 1” or 1 1/2” PVC hose length

SPECIFICATIONS

4

          Discharge maximum recommended 1” or 1 1/2” PVC hose length

Summary of Contents for Marine Elegance 241E

Page 1: ...improper installation or operation of this product WARNING HAZARD OF SHOCK OR FIRE Always use recommended fuse circuit breaker and wire size Motors used with this product are Ignition Protected They a...

Page 2: ...In Line Strainer if you have one No special toilet paper is required Water should appear in the bowl within ten seconds If not see troubleshooting section Hard objects or stringy substances paper tow...

Page 3: ...8 mm I D discharge hose approximately 3 feet 1 m long Two buckets Nontoxic antifreeze approximately 1 quart 1 liter Steps 1 Close the intake and discharge seacocks 2 Turn off power to unit 3 Disconnec...

Page 4: ...tings 5 For 120 240 VAC units use 12VDC specifications from transformer to unit Maximum suction of Intake Pump Maximum height above waterline 4 ft 1 2m from Intake Pump Maximum height of discharge ven...

Page 5: ...n guide with labels Additional Parts included with sea water model 1 Remote pump assy 2 Relay for remote pump SeaFresh models only Additional Parts Required MOUNTING Mounting Toilet Mounting surface m...

Page 6: ...NMENT LINES FIG 3 FIG 4 FIG 5 FIG 6 2 Place Mounting Template on deck against the wall with arrow located on center mark and secure with tape FIG 3 3 Drill holes for floor mounting brackets at locatio...

Page 7: ...Valve Waterline remote pump Electroscan Waterline Discharge Seacock Waterline Discharge Vented Loop Intake Vented Loop Discharge Seacock Intake Seacock Electroscan Pressurized Freshwater Model Install...

Page 8: ...its are available Use part 221147 for 1 hose or 221148 for 1 hose Intake Lines Pressurized Freshwater Models 1 Connect 13mm I D hose to pressurized freshwater supply 2 Install a shut off valve in inta...

Page 9: ...and fuse circuit breaker size from Specifications on Installation page 3 Install fuse circuit breaker in positive line at source 4 Wire control to the toilet and battery using one of the wiring diagr...

Page 10: ...4 10 Washer SS Flat 4 50 PLA26 Elbow Adapter 3 4 X 1 2 PARTS NOT SHOWN 221175 L Bolt 2 221170A Discharge Hose Support Strap F188 Well Nut 10 32 3 F144 Washer 10L 18 8 SS 2 MOUNTING BRACKET ASSEMBLY 22...

Page 11: ...11 EXPLODED PARTS L442 1221jlc...

Page 12: ...except as specifically set forth in this warranty 6 This warranty gives you specific legal rights and you may also have other rights which vary from state to state LIMITED WARRANTY 530 Orange Street...

Reviews: