Raritan Marine Elegance 241E Installation And Maintenance Instructions Manual Download Page 3

3

WINTERIZING 

Winterizing:

•  Improper winter lay up is a major cause of marine 

toilet failure.

•  Use only nontoxic antifreeze.
•  Flush toilet several times to clear waste from 

system.

•  Dispose of all antifreeze in accordance with local 

and federal regulations.

•  Winterize  holding  tanks,  plumbing,  treatment 

systems (MSD’s), etc. independently following 

manufacturer’s instructions. 

 

 

 

Pressurized Freshwater Models

Parts Required

•  1” (25 mm.) or 1 1/2” (38 mm.) I.D.  

discharge hose, approximately 3 feet (1 m.) long 

•  Two buckets 
•  Nontoxic antifreeze approximately 1 quart  
  (1 liter)

Steps

1.  Close discharge seacock (if one exists).
2.  Shut off intake water at source.
3.  Turn off power to unit.

4.  Disconnect and drain discharge hose.
5.  Disconnect intake hoses from water solenoid  

and place in one of the buckets.

6.  Connect short hose to toilet’s discharge and 

place in other bucket.

7.  Pour antifreeze in bowl.

8.  Turn on power to unit and flush until antifreeze 

is removed from the bowl and water is drained 

from the solenoid and hose.

9.  Disconnect power to toilet.

10.  Reconnect intake hoses to water solenoid.

Remote Intake Pump Models

Parts Required

3/4” (19 mm.) I.D. intake hose approximately 3 feet 
(1 m.) long. 
1” (25 mm.) or 1 1/2” (38 mm.) I.D. discharge hose 

approximately 3 feet (1 m.) long. 

Two buckets 

Nontoxic antifreeze approximately 1 quart (1 liter)

Steps

1.  Close the intake and discharge seacocks.

2.  Turn off power to unit.

3.  Disconnect and drain intake hose and discharge 

hose .

4.  Connect  short    hoses  to  toilet’s  intake  and 

discharge.

5.  Place one bucket under hose connected to 

toilet’s discharge.

6.  Pour nontoxic antifreeze in other bucket.

7.  Place hose connected to intake pump into 

bucket with antifreeze.

8.  Turn on power to unit and flush toilet until 

antifreeze begins to be discharged from toilet.

9.  Disconnect power from toilet.

RECOMMISSIONING

1.  Using the buckets, hoses and approximately 

one gallon (3.8 liters) of clean fresh water, flush 

antifreeze out of the toilet (see Winterizing).  

Dispose of antifreeze in accordance with local 

and federal regulations.

2.  Reconnect the intake and discharge hoses and 

open both seacocks and water source valve.

3.  Check all connections for leaks with several 

test flushes.

SYSTEM START-UP

1.  Open seacock(s).

NOTE

:  Pressurized freshwater models; open water 

source valve.
2.  Turn on power to toilet.
3.  Flush toilet per Operation Instructions.
4.  Check for leaks.

IMPORTANT:  If toilet does not flush properly 

or if water does not enter the bowl within 10 

seconds, refer to Troubleshooting.

Operation:

  Please see instructions included 

with control to see how to operate your unit.

L442  1221jlc                                                                                                             

Summary of Contents for Marine Elegance 241E

Page 1: ...improper installation or operation of this product WARNING HAZARD OF SHOCK OR FIRE Always use recommended fuse circuit breaker and wire size Motors used with this product are Ignition Protected They a...

Page 2: ...In Line Strainer if you have one No special toilet paper is required Water should appear in the bowl within ten seconds If not see troubleshooting section Hard objects or stringy substances paper tow...

Page 3: ...8 mm I D discharge hose approximately 3 feet 1 m long Two buckets Nontoxic antifreeze approximately 1 quart 1 liter Steps 1 Close the intake and discharge seacocks 2 Turn off power to unit 3 Disconnec...

Page 4: ...tings 5 For 120 240 VAC units use 12VDC specifications from transformer to unit Maximum suction of Intake Pump Maximum height above waterline 4 ft 1 2m from Intake Pump Maximum height of discharge ven...

Page 5: ...n guide with labels Additional Parts included with sea water model 1 Remote pump assy 2 Relay for remote pump SeaFresh models only Additional Parts Required MOUNTING Mounting Toilet Mounting surface m...

Page 6: ...NMENT LINES FIG 3 FIG 4 FIG 5 FIG 6 2 Place Mounting Template on deck against the wall with arrow located on center mark and secure with tape FIG 3 3 Drill holes for floor mounting brackets at locatio...

Page 7: ...Valve Waterline remote pump Electroscan Waterline Discharge Seacock Waterline Discharge Vented Loop Intake Vented Loop Discharge Seacock Intake Seacock Electroscan Pressurized Freshwater Model Install...

Page 8: ...its are available Use part 221147 for 1 hose or 221148 for 1 hose Intake Lines Pressurized Freshwater Models 1 Connect 13mm I D hose to pressurized freshwater supply 2 Install a shut off valve in inta...

Page 9: ...and fuse circuit breaker size from Specifications on Installation page 3 Install fuse circuit breaker in positive line at source 4 Wire control to the toilet and battery using one of the wiring diagr...

Page 10: ...4 10 Washer SS Flat 4 50 PLA26 Elbow Adapter 3 4 X 1 2 PARTS NOT SHOWN 221175 L Bolt 2 221170A Discharge Hose Support Strap F188 Well Nut 10 32 3 F144 Washer 10L 18 8 SS 2 MOUNTING BRACKET ASSEMBLY 22...

Page 11: ...11 EXPLODED PARTS L442 1221jlc...

Page 12: ...except as specifically set forth in this warranty 6 This warranty gives you specific legal rights and you may also have other rights which vary from state to state LIMITED WARRANTY 530 Orange Street...

Reviews: