Raritan CS16(R) User Manual Download Page 10

6

 

 

Figure 13. The front panel of CS16 

 

 

Figure 14. The front panel of CS16R 

Select a channel 

Selects the specific computer for viewing and operation. Be sure the light above the 
Scan button is OFF (toggle on/off).   

Press the button (1, 2, 3, 4, 5,...........or 16) corresponding to the desired channel. The 
light above the button will be ON, and the video from the computer connected to that 
channel will be displayed. You may now operate the computer using the keyboard and 
mouse.  

Scan channels 

Automatically cycles through the channels at a preselected scan rate, displaying each 
computer’s video. Default scan rate is set at 3 seconds.  

To activate, press the Scan button (toggle on/off). The light above the Scan button will 
be ON, and the unit will begin scanning.  

Set scan rate 

Adjusts the scan rate interval.  

Activate the Scan function. The light above the Scan 

button will be on. Press the button with the number that corresponds to the desired Scan 
rate (Ex.: figure 10 - Model:CS4). The light above the button will blink twice to 
acknowledge the setting, and scanning will continue at the new interval set.  

Summary of Contents for CS16(R)

Page 1: ...CompuSwitch User s Manual CS2 R CS4 R CS8 R CS16 R...

Page 2: ...53 Fax 31 10 284 4049 E mail sales europe raritan com Http www raritan com Raritan Computer Japan Inc Kuga Building 7F 11 6 Kuramae 4 chome Taitoo Ku Tokyo 111 0051 Japan Tel 81 3 5833 6360 Fax 81 3 5...

Page 3: ...rcial installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio commun...

Page 4: ...T Ta ab bl le e O Of f C Co on nt te en nt ts s Introduction 1 Features 1 Installation 1 Operation 4 Troubleshooting 9 Specifications 10 Cables 11 Accessories 11 Appendix 12...

Page 5: ...automatically cycle through all channels at a selectable scan rate from 1 to 16 seconds by using push buttons on the front panel and from 1 to 99 seconds by using Hot Key command SKIP function to aut...

Page 6: ...2 Figure 1 Back panel CS2 Figure 2 Back panel CS4 Figure 3 Back panel CS8 Figure 4 Back panel CS16...

Page 7: ...eyboard and mouse as if they were connected directly to the computer 6 After you have verified operation of one computer connect the remaining computers following steps 2 4 You may now begin using Com...

Page 8: ...d to set scan rate Front Panel Operation The front panel of the CompuSwitch 2 channel model Ex figure 6 7 has buttons marked 1 2 and buttons marked Scan 4 channel model Ex figure 8 9 10 has buttons ma...

Page 9: ...5 Figure 9 The front panel of CS4R Figure 10 Exploded view of Scan rates from a section of the front panel Figure 11 The front panel of CS8 Figure 12 The front panel of CS8R...

Page 10: ...keyboard and mouse Scan channels Automatically cycles through the channels at a preselected scan rate displaying each computer s video Default scan rate is set at 3 seconds To activate press the Scan...

Page 11: ...ress the key with the channel number of the connected computer press ENTER The light above the corresponding button on the front panel will be ON to indicate the channel selected For example select ch...

Page 12: ...selected key will now be the new Hot Key Mode activator figure 15 Quit Hot Key Mode To quit Hot Key Mode at any time press ESC The LEDs on the keyboard will stop blinking and the keyboard reverts to n...

Page 13: ...the problem is with the computer or the monitor If display is correct contact dealer for service Keyboard error on one machine Keyboard connection Check K B cable connection of the computer not opera...

Page 14: ...15 40 W x 7 87 D x 3 5 H 3 08kg 6 8 lbs Rackmount Models 2 Channel Model CS2R 483mm W x 193mm D x 44mm H 4 Channel Model CS4R 19 0 W x 7 6 D x 1 75 H 2 64kg 5 8 lbs 8 Channel Model CS8R 483mm W x 193...

Page 15: ...Video AT K B Serial Mouse Part No Length Connectors CCA20 2M 6 5ft DB25 M to HD15 M DIN5 M DB9 F CCA40 4M 13ft DB25 M to HD15 M DIN5 M DB9 F CCA60 6M 20ft DB25 M to HD15 M DIN5 M DB9 F CCA90 9M 30ft D...

Page 16: ...RCS24 to CS2 CS4 Refer to the following figure to install RCS24 to CS2 CS4 Where CS4 or CS2 Side Frame RCS24 2 pieces Round head screw M3x8mm 4 pieces Cable Support Bracket 2 pieces Round head screw M...

Page 17: ...t Kits RCS8 to CS8 Refer to the following figure to install RCS8 to CS8 Where CS8 Side Frame RCS8 2 pieces Round head screw M3x8mm 4 pieces Cable Support Bracket 2 pieces Round head screw M3x6mm 4 pie...

Page 18: ...ts RCS16 to CS16 Refer to the following figure to install RCS16 to CS16 Where CS16 Side Frame RCS16 2 pieces Round head screw M3x8mm 4 pieces Cable Support Bracket 2 pieces Round head screw M3x6mm 4 p...

Page 19: ...efer to the following figure to install cable bracket kits in CS2R CS4R Where CS2R CS4R Side Frame 2 pieces Round head screw M3x6mm 2 pieces Cable Support Bracket 1 pieces Flat head screw M3x6mm 2 pie...

Page 20: ...S8R Refer to the following figure to install cable bracket kits in CS8R Where CS8R Side Frame 2 pieces Round head screw M3x6mm 2 pieces Cable Support Bracket 1 pieces Flat head screw M3x6mm 2 pieces F...

Page 21: ...6R Refer to the following figure to install cable bracket kits in CS16R Where CS16R Side Frame 2 pieces Round head screw M3x6mm 4 pieces Cable Support Bracket 2 pieces Flat head screw M3x6mm 2 pieces...

Reviews: