background image

4

Crown Head Exchange Units
 

Crown Head Exchange Units are remanufactured 

units available as a service to the customer.  The 

old pump and motor assembly (LBA) are taken in 

trade on a remanufactured unit; the bowl, seat, lower 

cover and 

discharge fittings

 are kept and reused.   

When ordering directly from Raritan, a core charge 

is assessed until the old unit is received by Raritan.  
Subject  to  parts  and  production  availability, 

exchange units are not always available for shipment.  

Exchange units include the LBA along with a package 

of fasteners, new joker valve, mounting strips and a 

bowl gasket to remount the bowl to the LBA.  

CROWN HEAD SPECIFICATIONS

A.   

Nominal Voltage of Unit (Volts D.C.): 

 

 

12 

 

24 

 

32

  

 

    For 120/240 VAC units utilizing the rectified

 

    transformer, refer to 24 Volt D. C. Specifications

B. 

Amperage Draw @ Nominal Voltage

    

36   20   15

 

   

C. 

Circuit Breaker /Fuse Requirement (Amps):

  

50   30   20

 

     

D. 

Wire Gauge Sizes (AWG) Circuit  Length, 

 

Battery to Crown Head and Back: 

0-15 Ft. 

 #6 

 #10 

 #10

 

 

 

 

 

 

16-25 Ft. 

#4 

 #10 

 #10

 

 

 

 

 

 

26-50 Ft. 

#2 

 

  #8 

 

#10

 

 

 

 

 

 

Over 50 Ft.  Refer to ABYC (E-9) Recommendations

E. 

Switch Wire Size:

 

 

 

  0-50 Ft. 

#14  

#14  

#14

 

Switch Wire Fuse Size (Amps):

       

 

 

    

    3 

 

    3 

 

    3

F. 

Maximum Height of Discharge Vented Loop:

 

4 Ft. From Base of Toilet

H. 

Maximum Suction of Inlet Pump

 

(Allowable Height of Toilet Above Waterline): 

3 Ft. From Base of Toilet

I. 

Duty Cycle:

 

 

 

 

 

 

30 Seconds On; 120 Seconds Off

ONBOARD FRESHWATER USE: If you would like 

to retrofit your current Crown Head for use with pres

-

surized freshwater please contact Raritan Technical 

Support.

1

THE  FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND 

FOLLOWED DURING BOTH INSTALLATION AND OPERATION.

WARNING: 

Raritan Engineering Company, Inc. recommends that a qualified person or electrician install this 

product.   Equipment damage,  injury  to  personnel  or death could result from improper instal-

lation.  Raritan Engineering Company, Inc. accepts no responsibility or liability for damage to 

equipment, injury or death to personnel that may result from improper installation operation of 

this product.

WARNING:  HAZARD OF SHOCK OR FIRE  

 

Always use recommended fuse, circuit breaker and wire size.

 

Motors and relays used with this product are “Ignition Protected”.  They are not however, ex- 

 

plosion-proof as defined in 46CFR 110.15-65(e), Subchapter J-Electrical Engineering. 

   

 

DO NOT

 run this system dry (without water).

   

 

DO NOT

 run continuously for more than 30 seconds.  

WARNING:  HAZARD OF FLOODING 

- Always shut off seacock(s) before leaving the boat unattended.  

 

Whenever  possible  hose  connections  should  be  secured  using  two (2) all-stainless steel hose  

 

clamps.  Integrity of clamps, hoses and fittings should be checked periodically.

 

INTRODUCTION

The  Crown  Head  is  a  powerful  centrifugal 

macerating toilet that thoroughly breaks down 

waste in preparation for treatment or holding and 

requires little maintenance.  It can be ordered with 

a 90 degree or a straight discharge fitting, a white 

marine-size bowl or household-style bowl available 

in either white or almond.  

OPERATION

CAUTION:

  

The Crown Head motor is designed 

to be used as a toilet and is not rated for 

continuous duty. 

The Crown Head doesn’t require special toilet  paper, 

however, hard objects or stringy substances (paper 

towels, feminine hygiene products, filter cigarettes, 

etc.) 

must not

 be thrown into the toilet as they will 

cause damage.

A.  Momentary Operation Using Push-button 

Switch (#164000BR) - not included:  

Depress 

button and hold.  Water should appear in the 

bowl  within  one  to  four  seconds.    Flush  as 

necessary.

 

     

 

      

  

MAINTENANCE

1.  Refill the reservoir when empty; occasionally 

check that it has not run dry. 

  C.P., Cleans Potties, (1PCP22) helps minimize 

the need for cleaning.

Use only Raritan Cleans Potties as an additive in 

the Concentrate tank.  Other products may cause 

damage to the internal parts of the toilet.  

2.  Using C.P. a bio-enzymatic toilet bowl cleaner 

(available from Raritan Engineering) will keep 

the bowl clean and fresh smelling.

Do not use any chemical that contains ammonia, 

ethyl acetate, phosphoric acid or concentrated 

chlorine bleach as a cleaner.  These may cause 

damage to the toilet.

3.   Make a periodic visual check for leaks at the base of 

the toilet and at hose connections.

4.   Check semiannually to ensure all wire terminals and 

junctions are corrosion-free.

5.  When boat is not in use, flushing the system with fresh 

water will help minimize odors and reduce mineral 

buildup.

L91  0116jlc

 

1

crown head

CENTRIFUGAL DISCHARGE SERIES AUTOMATIC MARINE TOILET

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

1

THE  FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND 

FOLLOWED DURING BOTH INSTALLATION AND OPERATION.

WARNING: 

Raritan Engineering Company, Inc. recommends that a qualified person or electrician install this 

product.   Equipment damage,  injury  to  personnel  or death could result from improper instal-

lation.  Raritan Engineering Company, Inc. accepts no responsibility or liability for damage to 

equipment, injury or death to personnel that may result from improper installation operation of 

this product.

WARNING:  HAZARD OF SHOCK OR FIRE  

 

Always use recommended fuse, circuit breaker and wire size.

 

Motors and relays used with this product are “Ignition Protected”.  They are not however, ex- 

 

plosion-proof as defined in 46CFR 110.15-65(e), Subchapter J-Electrical Engineering. 

   

 

DO NOT

 run this system dry (without water).

   

 

DO NOT

 run continuously for more than 30 seconds.  

WARNING:  HAZARD OF FLOODING 

- Always shut off seacock(s) before leaving the boat unattended.  

 

Whenever  possible  hose  connections  should  be  secured  using  two (2) all-stainless steel hose  

 

clamps.  Integrity of clamps, hoses and fittings should be checked periodically.

 

INTRODUCTION

The  Crown  Head  is  a  powerful  centrifugal 

macerating toilet that thoroughly breaks down 

waste in preparation for treatment or holding and 

requires little maintenance.  It can be ordered with 

a 90 degree or a straight discharge fitting, a white 

marine-size bowl or household-style bowl available 

in either white or almond.  

OPERATION

CAUTION:

  

The Crown Head motor is designed 

to be used as a toilet and is not rated for 

continuous duty. 

The Crown Head doesn’t require special toilet  paper, 

however, hard objects or stringy substances (paper 

towels, feminine hygiene products, filter cigarettes, 

etc.) 

must not

 be thrown into the toilet as they will 

cause damage.

A.  Momentary Operation Using Push-button 

Switch (#164000BR) - not included:  

Depress 

button and hold.  Water should appear in the 

bowl  within  one  to  four  seconds.    Flush  as 

necessary.

 

     

 

      

  

MAINTENANCE

1.  Refill the reservoir when empty; occasionally 

check that it has not run dry. 

  C.P., Cleans Potties, (1PCP22) helps minimize 

the need for cleaning.

Use only Raritan Cleans Potties as an additive in 

the Concentrate tank.  Other products may cause 

damage to the internal parts of the toilet.  

2.  Using C.P. a bio-enzymatic toilet bowl cleaner 

(available from Raritan Engineering) will keep 

the bowl clean and fresh smelling.

Do not use any chemical that contains ammonia, 

ethyl acetate, phosphoric acid or concentrated 

chlorine bleach as a cleaner.  These may cause 

damage to the toilet.

3.   Make a periodic visual check for leaks at the base of 

the toilet and at hose connections.

4.   Check semiannually to ensure all wire terminals and 

junctions are corrosion-free.

5.  When boat is not in use, flushing the system with fresh 

water will help minimize odors and reduce mineral 

buildup.

1/2” (1.3cm) 

(approx.)

2”

(5.1cm)

13 7/8” (34.2cm)

10 7/8” (27.6cm)

 11 7/8” (30.2cm)

14 3/8”(36.5)Household-style

13”(33cm) 

Marine-size

17 3/8” 

(44.1cm)

Household-style

17” 

(43.2cm)

Marine-size

FIG 1

Side

Front

6 1/4” 

(15.9cm)

8 9/16”

(21.9cm)

20”(50.8cm) Household-style 

17”(43.2cm) 

Marine-size

L91  0116jlc

 

1

CROWN HEAD - Overall Dimensions

crown head

CENTRIFUGAL DISCHARGE SERIES AUTOMATIC MARINE TOILET

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

NOTE:  Pre-11/87 Standard LBA’s utilized a flapper valve on the discharge.  If replacing this model, please 

mention it when ordering; a special discharge fitting will have to be added to the order.  Breaker and wire 

sizes will have to be increased - see Specifications below.

L91  1022jlc

Summary of Contents for Crown Head CW912

Page 1: ...e or household style bowl OPERATION CAUTION The Crown Head motor is designed to be used as a toilet and is not rated for continuous duty The Crown Head doesn t require special toilet paper however har...

Page 2: ...ly siphonandcheck valve assembly Concentrate tank 2 oz 59ml of C P two mounting strips and an owner s manual Crown Head units purchased for use with 120 240 volt AC power will also include a rectified...

Page 3: ...Fuse or Circuit Breaker See Specification Chart Pos Voltage from Battery or DC Power Panel Battery Lug Solenoid Relay CDS 14 Awg Wire Ground Neg Crown Head Pos Wiring the Crown Head DC Unit with Momen...

Page 4: ...empty occasionally check that it has not run dry C P Cleans Potties 1PCP22 helps minimize the need for cleaning ethyl acetate phosphoric acid or concentrated chlorine bleach as a cleaner These may cau...

Page 5: ...eplace impeller loose from center bushing 2G Clogged strainer 2G Clean debris from strainer 3 Foul odors from toilet area 3A Marine life lodged in rim of bowl 3A Remove and flush bowl with pressure ho...

Page 6: ...on F149VT Set Screw 2 G15 Impeller Washer 2 G13W Pump Impeller Assembly w 2 G15 G2M Impeller Wear Plate M23A Lockwasher 4 M30 Hex Nut Brass 2 M31 Flat Washer Brass 2 RNI Nylon Bowl Mounting Washer 4 V...

Page 7: ...Clamp 7 L91 0116jlc Specify Voltage 7 L91 0116jlc M23A C253 CH55A G13W CHM Specify Voltage CH136 CH37E CH29A CH291 crown head EXPLODED PARTS VIEW CENTRIFUGAL DISCHARGE SERIES CH136 CH37 CR1 CH58 1118...

Page 8: ...to or misuse of this product This warranty also does not cover damages to equipment caused by fire flood external water excessive corrosion or Act of God 3 ANYEXPRESSWARRANTYNOTPROVIDED HEREIN ANDANYR...

Reviews: