background image

below the water line 

vented loops must be installed

as shown in Fig. #2 to prevent back siphoning.

  All

thru-hull fittings should include readily accessible
seacocks for safety and to simplify maintenance.
(This recommendation is made by marine
underwriters for all installations.)
1.   Mount the unit securely on a flat solid deck (see

Fig. #3 for mounting template measurements)
using stainless steel bolts, nuts and large washers
or use lag screws long enough not to pull out.

2. Use 3/4'' (19 mm) I.D. reinforced hose for intake

connections and 1 1/2'' (38 mm) I.D. sanitation
hose (#SH available from Raritan) for  discharge.

3. Fittings and 90 degree bends should be kept to a

minimum to maintain proper performance.

SUGGESTIONS:

A.  The use of a Raw Water Strainer (#RWS), on the

inlet line is recommended.  This will help keep
odors down and prevent clogging.

B. Intake and discharge thru-hull fittings (if used)

should be as far apart as practical, preferably on
opposite sides of the keel.  This will help to
minimize the possibility of discharge water being
drawn back into the intake.

MAINTENANCE

With normal use very little maintenance is required
other than inspection and periodic replacement of
rubber parts.  Using C.P. (#1PCP22), a bio-enzymatic
toilet bowl cleaner (available from Raritan
Engineering) will keep the bowl clean and fresh

smelling.  Introducing
Raritan Concentrate into
flush water through a Toilet
Water Kit (#TWK) will
deodorize and lubricate the
unit.

CAUTIONS:Using im-
proper deodorants or
cleaners can result in dam-
age to rubber and plastic
parts.  DO NOT USE prod-
ucts containing pine oil,
formaldehyde, phosphoric
acid, chlorine or any sol-
vent or petroleum-based
products.

A 3/32" Allen Wrench has
been included in the owners
packet for removal of flush
handle assembly set screw
(#F149VT) if needed.
Before attempting repairs,
refer to the Troubleshooting
section of this manual.

Cricket

Marine Toilet

TWK

Waterline

Discharge

Thru-Hull Fitting

and Seacock

Waterline

Intake

Thru-Hull Fitting

and Seacock

Raw

Water

Strainer

Drawing Not To Scale

Lectra/San MC

Waterline

Raw

Water

Strainer

TWK

Y Valve

Holding Tank

Vented Loop

Lectra/San MC

Vented

Loop

Deck Pumpout

Vent Line to

Outside of

Hull or Deck

Drawing Not To Scale

Waterline

FIG. #1, ABOVE WATERLINE INSTALLATION

FIG. #2, BELOW WATERLINE INSTALLATION

Discharge

Thru-Hull

Fitting

and

Seacock

Intake

Thru-Hull

Fitting

and

Seacock

Cricket