background image

14 

Kestrel/USER-MANUAL/REV1.1/08-20 

8.3 Acquiring a Live Image Sequence 

There are two things to observe in the control panel that inform you that the camera is 
connected and ready to image. 

 

The serial connect checkbox must be ticked in the control panel. This informs you that you 
have established a serial connection with the camera and can control the camera. 

Secondly, the symbol near the bottom right of the control panel will have three moving dots. 
This indicates that you are obtaining video data from the camera. The imaging statistics 
displayed directly underneath the imaging window will also inform you if you are receiving a 
video feed from the camera. 

Once you have established a serial connection with the camera and are receiving video 
data, you can now grab a live image feed. Clicking the 

“Live”

 button will grab a live image 

sequence which you will now see in the imaging window. 

For the Kestrel, you will have to enable contrast modification after going live. For 
instruction on how to do this on XCAP, please refer to section 10.2. 

The symbols in the control app discussed above are displayed in Figure 5. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 5: Port Tab – Checking Camera.

 

Summary of Contents for KE60V-BV-CL

Page 1: ...1 Kestrel USER MANUAL REV1 1 08 20 Kestrel Model KE60V BV CL USER MANUAL...

Page 2: ...CHILLER SETUP 9 6 1 Connecting Camera to Frame Grabber 9 6 2 Connecting Camera to Chiller 9 6 3 Recommended Coolants for Chiller 9 6 4 Setting the Coolant Temperature for Re circulation 9 6 5 Drainin...

Page 3: ...USER MANUAL REV1 1 08 20 9 5 Maximum Frame Rates 18 9 6 Thermoelectric Cooler TEC 18 9 7 Information Tab 19 10 XCAP CONTROL FEATURES 20 10 1 Saving Preset Settings 20 10 2 Contrast Modification XCAP S...

Page 4: ...and explained with the use of XCAP Imaging software which is the core plug and play software package that is offered with Raptor cameras An image of the camera is shown in Figure 1 2 CAMERA CARE 2 1...

Page 5: ...eed low noise electronics provide linear response and sensitivity for rapid image capture The Camera Link digital interface provides the most stable platform for data transfer and the camera will work...

Page 6: ...estrel USER MANUAL REV1 1 08 20 4 DESIGN OVERVIEW 4 1 Mechanical Model PDF of mechanical model available from our website https www raptorphotonics com products kestrel emccd Units shown in mm and inc...

Page 7: ...or Optical Table The camera has a 20 BSW Whitworth threaded hole to mount to a tripod or an optical table 2 3 4 1 6 1 Label Recess 2 3M Camera Link connector Part 12226 1150 00FR 3 SMA connector Trigg...

Page 8: ...n request Raptor can create a LabView icd file which can be used to control the camera on National Instruments imaging tool NI MAX The file may also be useful if attempting to create your own LabView...

Page 9: ...free path for flow of air entry and exit at the left side and right side of the T257P chiller prior to operation 4 Remove the reservoir cap and add coolant to the reservoir until the fluid reaches th...

Page 10: ...sed on the amount of use you may need to perform this more frequently For more detailed information please refer to the Thermotek user manual If using another model of chiller please refer to its user...

Page 11: ...CI EB1 providing roughly 200MB sec maximum bandwidth Contact EPIX Inc for further information regarding minimum computer laptop specification requirements to run the XCAP Imaging Software http www epi...

Page 12: ...Pre release version with support for the latest cameras and latest PIXCI imaging boards Open the downloaded file when complete and follow the onscreen instructions in the installation wizard If a pop...

Page 13: ...all control parameters set to the default states Open w Last used Video Setup will open the control panel with all parameters set at the last known state Once this option between the two has been sele...

Page 14: ...ou are obtaining video data from the camera The imaging statistics displayed directly underneath the imaging window will also inform you if you are receiving a video feed from the camera Once you have...

Page 15: ...ling the amount of voltage that the EM gain register in the camera is seeing The relationship of gain to the DAC value is exponential so up until around 3000 on the slider there is a minimal gain bein...

Page 16: ...camera into external trigger mode Enabling the external trigger will open the trigger polarity options rising or falling edge There is a slight drop off in the maximum frame rate in external trigger m...

Page 17: ...x2 and 4x4 9 4 Exposure Time and Frame Period The exposure time and frame period controls are active in the control panel under all tabs except the port and info tabs Unless Live FFR mode discussed in...

Page 18: ...ling is 20 C If only using the fan the minimum cooling temperature is 20 C For important information on using the liquid cooling with the chiller please refer to sections 6 2 6 5 The actual TEC set po...

Page 19: ...Information Tab The Info tab displays the manufacturers data of the camera such as the firmware version serial number etc The sensor and PCB temperature can also be read from this tab The Info tab is...

Page 20: ...frame grabber settings can be saved in the Preset tab under the PIXCI relevant frame grabber model number section of the GUI as shown in Figure 12 Up to three different presets can be saved per settin...

Page 21: ...en imaging the camera If applying ROI or binning controls the contrast modification will have to be re enabled each time In the contrast modification box that can be seen from Figure 14 select Stretch...

Page 22: ...22 Kestrel USER MANUAL REV1 1 08 20 CORPORATE HEADQUARTERS Raptor Photonics LTD Willowbank Business Park Larne Co Antrim BT40 2SF Northern Ireland PH 44 2828 270141 www raptorphotonics com...

Reviews: