Operating instructions RS wash 

 D wash 

 P wash 

 SHERAprint wash 

 3Dewash

 

 

 

 

Rapid Shape GmbH 

 DOCR000257 

16 

 29 

 

4.2.2

 

Setting up the machine 

 

For setting up the machine please proceed as follows: 

1.

 

Prerequisite: The machine has already been unpacked. 

 

Chapter 3.3 

2.

 

Lift the machine and accessories to the desired installation 
location and set them down. 

3.

 

Remove all transport locks from the machine and the 

accessories. 

4.

 

Make sure that the four feet of the machine are completely 
resting on the ground. 

5.

 

Place the cleaning liquid container next to the machine. 

 

4.3

 

Connecting 

4.3.1

 

Power connection 

 

To make the power connection, please proceed as follows: 

1.

 

Prerequisite: The machine has already been set up. 

 

Chapter 4.2.2 

2.

 

Slide the cap of the power plug back until the stop and hold the 
cap in this position. Then insert the plug into the power 
connection of the machine. 

Pay attention to the positioning of the plug. The flat plug side 

must point inwards!

 

3.

 

Then, connect the power supply to the nearest outlet. Be careful 
not to trip over cables lying around. 

4.

 

Recommended: Connect a network cable to the Ethernet port on 

your machine and to your network interface. In this way, 

software updates can be installed automatically.

 

5.

 

Then switch on the machine. 

 Chapter 6.2

 

 

4.3.2

 

Cleaning liquid container 

 

For equipping and connecting the cleaning liquid container please 
proceed as follows: 

1.

 

Prerequisite: The machine has already been switched on. 

 

Chapter 6.2 

2.

 

Call up the bottle change wizard on the user interface. Start the 
wizard. 

3.

 

Remove the lid of the cleaning liquid container and place it 
upside down (tubes facing upwards) on a flat surface. 

4.

 

Slide the bottom of the container to the RFID reader. 

5.

 

Unscrew both bottles with cleaning liquid. Place the bottle caps 
in the appropriate storage compartments of the container base. 

6.

 

Insert a bottle in the rear position of the container. Pay attention 
to the position markings on the bottle and container. The RFID 
tag on the bottle is read. 

7.

 

Insert the second bottle in the front position of the container. 

Pay attention to the position markings on the bottle and 
container. The RFID tag on the bottle is read. 
 

8.

 

Put the lid back on. Insert the tubes into the bottle openings. 

When doing so, make sure that the container is not removed 

from the RFID reader.

 

Summary of Contents for RS wash

Page 1: ...SHERAprint wash 3Dewash Original operating instructions Rapid Shape GmbH Roemerstra e 21 71296 Heimsheim Germany Phone 49 0 7033 309 878 0 info rapidshape de www rapidshape de Revision 09 07 2019 Ver...

Page 2: ...lations and general safety regulations apply to the area of application of the machine Redistribution and duplication of this document utilisation and communication of its contents are strictly prohib...

Page 3: ...3 3 1 Safety during transport 13 3 2 Transporting the machine 13 3 3 Unpacking the Machine 13 3 4 Scope of delivery 14 3 5 Storing the machine 14 4 Installation 15 4 1 Safety during installation 15 4...

Page 4: ...4 8 2 Overview of the cleaning maintenance work 24 8 2 1 Change cleaning bottles 24 8 2 2 Check and clean inner container 25 8 2 3 Check hose connections 26 8 2 4 Change the activated carbon filter 26...

Page 5: ...symbol and signal word indicates a potentially dangerous situation which may lead to death or severe injury if not avoided CAUTION This combination of symbol and signal word indicates a potentially d...

Page 6: ...manual Any use going beyond the intended use or otherwise is deemed to be improper The operator is exclusively liable for any resulting damage Use contrary to the intended use includes but is not limi...

Page 7: ...ified electricians and in compliance with the relevant safety and VDE regulations Machines with damage to the power cord insulation or lack of earthing must be disconnect ed from the mains immediately...

Page 8: ...id containers may only be lifted and tilted if the bottles contained in them had been removed first If necessary wear appropriate protective clothing Read the appropriate safety data sheets carefully...

Page 9: ...cessary accessories and can recognise possible dangers independently and avoid hazards Operator obligations The operator is obligated to read these operating instructions fully before using the system...

Page 10: ...ct people from negative impacts on their safety and health Personnel must wear personal protective equipment while working on and with the machine as referred to in the individual sections of this man...

Page 11: ...DOCR000257 2 1 Machine Assembly Operating Elements Figure 1 Machine overview Lid USB Ethernet connection Coupling connection Power on off button RFID reader Quick coupling Drawer extension Cleaning li...

Page 12: ...29 Figure 2 Overview cleaning liquid container Cleaning bottle 1 dirty Cleaning bottle 2 clean Container bottom Lid 2 2 Serial plate The serial plate is situated on the machine rear It shows the most...

Page 13: ...d to the transport company and Rapid Shape Transport The machine can be transported by one person 1 Grasp the bottom of the transport packaging and transport it to the destination 2 Then unpack the ma...

Page 14: ...y Cleaning liquid container Optionally additional accessories can be supplied For more information please contact Rapid Shape 3 5 Storing the machine Store the machine in a dry dust free and frost pro...

Page 15: ...mediately Connect the mains plug to the nearest and correctly grounded socket of the machine Only operate the machine with the mains voltage specified for the machine Only operate the machine with the...

Page 16: ...ound 4 Recommended Connect a network cable to the Ethernet port on your machine and to your network interface In this way software updates can be installed automatically 5 Then switch on the machine C...

Page 17: ...he cleaning liquid needs to be changed and with a note on the user interface alerts you of a required bottle change Chapter 8 2 1 4 3 3 Connect to other machines The cleaning unit can be connected to...

Page 18: ...Operating instructions RS wash D wash P wash SHERAprint wash 3Dewash Rapid Shape GmbH DOCR000257 18 29 In an emergency proceed as follows 1 Unplug the mains plug...

Page 19: ...he material manufacturer 6 2 Switching on the machine To switch on the machine please proceed as follows 1 Prerequisite The machine has already been fully connected Chapter 4 3 2 Turn the machine on u...

Page 20: ...we recommend inserting hollow models with the cavities downwards 6 4 Select operating mode start To start the cleaning process you can choose from the following three operating modes Operating mode J...

Page 21: ...aning process 6 4 2 Operating Mode Material In the Material operating mode the cleaning process is performed based on the materials used To start the process please proceed as follows 1 The inner cont...

Page 22: ...f the component observe the specifications of the material manufacturer when creating custom parameters Only by observing the instructions of the manufacturer can safe biocompatibility be ensured For...

Page 23: ...down will appear The machine counts for 10 seconds until the switch off happens automatically 3 Wait for the machine to shut down completely 4 Switch off the machine using the power on off button 7 2...

Page 24: ...s to avoid material damage to the machine 8 2 Overview of the cleaning maintenance work Interval What How Depending on use autom display Change cleaning bottles Chapter 8 2 1 1 month Check inner conta...

Page 25: ...ing so make sure that the container is not removed from the RFID reader 11 Reconnect the container to the coupling connection of the machine The coupling must click in audibly 12 Finish the wizard on...

Page 26: ...eparate installation instructions are enclosed with the spare parts 6 Close the lid and fasten it firmly to the housing with the fastening screws 7 Close the drawer 8 Check the hoses in the cleaning l...

Page 27: ...ore the disassembly work begins Wear appropriate protective clothing Disassemble components properly Handle edged and pointed components carefully If necessary secure components so that they can not f...

Page 28: ...ENVIRONMENTAL PROTECTION Incorrect disposal of electronic waste electronic components lubricants and other additives can be hazardous to the environment Therefore please dispose of machine components...

Page 29: ...Ambient temperature C 15 to 40 Storage temperature C 15 to 70 Max humidity 70 All values are approximate 10 2 Dimensions and weights Width mm 230 Height mm 270 Depth mm 380 500 closed open Weight kg 8...

Reviews: