en-45
CONTROLS 5
5.7 COOLING FAN OPERATION ______________________________________________
The mower is equipped with an engine cooling fan that can be reversed to clear debris from the hood intake
grilles.
The fan reversal function operates in one of three modes –
·
Disabled
– The fan operates in normal forwards direction only and
does not reverse at any time, either Manually or Automatically.
·
Manual
– The fan operates in normal forwards direction and only
reverses on demand when
Button 1
on the display is pressed.
·
Timer
– The fan operates in normal forwards direction and reverses
automatically at set time period intervals. The fan can also be
reversed manually while set to Timer mode.
·
·
The fan mode is selected via the Menu in the display as follows –
1. Press
Button 4
to enter the
Main Menu
.
2. Use
Button 3
to scroll to
Settings
followed by
Button 4
to enter the
Settings Menu
.
3. Use
Button 3
to scroll to
PIN
followed by
Button 4
to enter the
Enter
PIN
page.
4. Enter the Owner PIN (default 1001) to enter the
PIN Menu
page.
5. Use
Button 3
to scroll to
Fan Drive
followed by
Button
4 to enter the
Fan Drive Reverse
page.
6.
Buttons 2 & 3
can then be used to scroll to the desired mode setting
followed by
Button 4
to set.
7. The Timer time interval is factory set to 30 minutes however can be
adjusted from 5 minutes to 40 minutes in 5 minute intervals using
Buttons 2 & 3
, before exiting via
Button 1
.
Note:
·
During a manual or automatic fan reversal a fan icon will be visible on the display screen.
·
Fan rotation in normal forwards direction does not start until the engine reaches 70°C. Fan reversal is
only possible once the fan has started rotating.
·
It is not possible for either a manual or automatic fan reversal to occur for the first 2 minutes following the
fan starting to rotate.
·
If either a manual or automatic fan reversal cycle has just been completed, it will be necessary to wait 60
seconds before a further manual reversal can be requested.
·
·
WARNING
The fan can start unexpectedly while the engine is running. Always make sure that the correct PPE
is worn while cleaning or during maintenance of this vehicle.
Keep hands and loose-fitting clothing, jewellery or hair away from the fan at all times.
1234
123.4 Hours
P
TM
MODE
Fan Drive Reverse
Disabled
Manual
Timer [ 30 min ]
!
Summary of Contents for MP653
Page 8: ...en 6 2 INTRODUCTION NOTES ...
Page 54: ...en 52 5 CONTROLS NOTES ...
Page 85: ...en 81 ADJUSTMENTS 7 NOTES ...
Page 87: ...en 83 MAINTENANCE AND LUBRICATION 8 B B A A B B B A A B ...
Page 113: ...en 109 MAINTENANCE AND LUBRICATION 8 NOTES ...
Page 123: ...en 119 QUALITY OF CUT 10 NOTES ...
Page 126: ...en 122 11 FUSES RELAYS AND CONTROLLER NOTES ...
Page 129: ...en 127 SPECIFICATIONS 12 A B E D L C K H M J ...