Ransburg RCS Series Service Manual Download Page 13

 

Positive Displacement Pump  - Operation 

LN-9415-01 

10 

OPERATION 

If the inlet pressure of the pump is too low, 
the  pump  will  be  starved  for  material  and 
will  cavitate,  resulting  in  lower  flows  than 
expected.    Additionally,  if  the  outbound 
pressure is significantly higher than the inlet 
pressure, the gears will slip by the material, 
also  causing  the  flow  to  be  less  than  ex-
pected. 
 
On  the  other  hand,  if  the  inlet  pressure  is 
too  high  (especially  at  low  viscosities), 
material  can  “blow  by”  the  gears  in  the 
meter  and  the  resultant  flow  will  be  higher 
than expected. 
 
Positive displacement gear pumps are most 
accurate  when  the  pressure  across  the 
pump  (known  as  differential  pressure)  is 
minimized.  That is, if the inlet pressure can 
be  maintained  at  a  pressure  that  is  very 
close  to  the  outlet  pressure,  the  most 
accuracy  will  be  realized.    The  RCS  and 
RCS-2  Systems  have  the  ability  to  control 
the  inlet  pressure  automatically  based  on 
the  value  of  the  outlet  pressure.    This, 
however,  is  an  optional  feature.    If  you  are 
interested  in  enabling  this  feature  on  your 
RCS  or  RCS-2  System,  contact  your 
Ransburg representative. 

PRINCIPLE OF OPERATION 

 
The  external  gear  pump  is  a  positive  dis-
placement  (PD)  type  of  pump  generally 
used  for  the  transfer  and  metering  of  liq-
uids. The gear pump is a precision machine 
with extremely tight fits and tolerances, and 
is capable of working under high differential 
pressures. 
 
Typically  there  is  a    drive  gear  driven  by  a 
motor  that  rotates  an  idler  gear  in  the 
opposite  direction.  When  the  gears  rotate, 
the liquid, which is trapped in the gear teeth 
spaces  between  the  housing  bore  and  the 
outside of the gears, is transferred from the 
inlet side of the pump to the outlet side. The 
pumped liquid moves around the outside of 
the  gears  and  not  between  the  gears.  The 
rotating  gears  continue  to  deliver  a  fresh 
supply of liquid from the suction (inlet) side 
of the pump to the discharge (outlet) side of 
the  pump,  with  virtually  no  pulsations.  The 
meshing of the gears on the discharge side 
of  the  pump  forces  the  liquid  out  of  the 
pump and into the discharge port. 
 
Flow  rate  through  the  pump  is  controlled 
simply  by  varying  the  RPM  of  the  motor 
driving  the  pump.    On  RCS  and  RCS-2 
Systems,  it  is  recommended  that  the  RPM 
of  the  pump  not  be  allowed  to  exceed  150 
RPM’s. 
 
The  accuracy  of  the  gear  pump  is  directly 
affected by both the viscosity of the material 
being  pumped  and  the  differential  pressure 
across the pump. 
 
If  the  material  is  too  thin  (e.g.  viscosities 
less  than  30  centipoise),  it  will  not  be 
properly  metered  by  the  pump  and  inaccu-
rate flow rates will result. 

Summary of Contents for RCS Series

Page 1: ...eries A13619 00 0 3 cc rev A13620 00 0 6 cc rev A13621 00 1 8 cc rev A13635 00 3 0 cc rev IMPORTANT Before using this equipment carefully read all SAFETY PRECAUTIONS starting on page 1 and all instruc...

Page 2: ...Positive Displacement Pump LN 9415 01 N O T E S...

Page 3: ...ONS 7 SPECIFICATIONS 7 8 INSTALLATION 9 GENERAL INFORMATION 9 SYSTEM STARTUP 9 OPERATION 10 PRINCIPLE OF OPERATION 10 SERVICE PARTS 11 DISASSEMBLY FLUSHABLE 11 REASSEMBLY FLUSHABLE 12 PARTS LIST FLUSH...

Page 4: ...make such variations inevitable Compare this manual with your system instal lation drawings and appropriate Ransburg equipment manuals to reconcile such differ ences Careful study and continued use o...

Page 5: ...used for general cleaning must have a flash point at minimum of 5 C 9 F greater than the ambient temperature It is the end users responsibility to insure this condition is met Spray booth ventilation...

Page 6: ...described in the corresponding section of the equipment manual Protection against inadvertent arcing that is capable of causing fire or explosion is lost if the current over load sensitivity is not p...

Page 7: ...d Rubber soled insu lating shoes should not be worn Grounding straps on wrists or legs may be used to assure adequate ground contact Operators must not be wearing or carrying any ungrounded metal obje...

Page 8: ...must be located outside Class I or II Division 1 and 2 hazardous areas in accordance with NFPA 33 and EN 50176 Turn the power supply OFF before working on the equipment Test only in areas free of flam...

Page 9: ...The chemical re action caused by these solvents reacting with aluminum can be come violent and lead to an equipment explosion Aluminum is widely used in other spray application equipment such as mater...

Page 10: ...with a 22 337 by pass valve provides faster color changes and minimizes solvent usage WATER BASED APPLICATIONS The DLC pumps can be used in waterborne applications overall It is highly recommended tha...

Page 11: ...440B 440B 440B 440B Shaft Gear Material 440B 440B 440B 440B 440B 440B 440B Hardness DLC Vickers 2500 2500 2500 2500 2500 2500 2500 Working Pressure max PSI 300 300 300 300 300 300 300 Input pressure...

Page 12: ...specified torque settings INSTALLATION RCS RESIN PUMP MOUNTED ILLUSTRATION MAX TORQUE FOR MOUNTING BOLTS 17 LB FT 23 N m Note TORQUE REQUIREMENTS AND TIGHTENING PROCEDURES HAVE THE SAME TORQUE SPECIF...

Page 13: ...of pump generally used for the transfer and metering of liq uids The gear pump is a precision machine with extremely tight fits and tolerances and is capable of working under high differential pressur...

Page 14: ...ide gear off of shaft 7 Pull seal 10 from front plate use seal puller or drive from opposite side Be careful not to damage the pump bore dur ing removal Please Note Driven shaft is fixed in the body a...

Page 15: ...aft on bottom plate 4 Install middle plate 4 5 Install drive shaft and gear 6 into bot tom plate assembly 6 Install O rings 8 9 into grooves on top of plate 7 Assemble top plate 3 onto pump as sembly...

Page 16: ...KIT CHART B BELOW 7 1 KEYWAY N A 8 2 A13790 00 O RING INCLUDED IN A13790 KIT 9 2 A13790 00 O RING INCLUDED IN A13790 KIT 10 1 22 315 SEAL RADIAL INCLUDED IN A13790 KIT SEE FIGURE 1 4 EXPLODED PUMP VIE...

Page 17: ...it will only slide out in one direction 5 Remove the center plate 9 carefully 6 Slide drive gear off of shaft 7 Pull seal 15 from front plate use seal puller or drive from opposite side Be careful no...

Page 18: ...nstall circlip on drive shaft closest to front plate 5 Install key 7 Slide on drive gear 5 and install second circlip 6 Install a new O ring 10 on bottom plate and top plate in appropriate O ring groo...

Page 19: ...PLATE CENTER SEE KIT CHART A BELOW 10 2 A13791 00 O RING INCLUDED IN A13791 KIT 11 12 13 14 PLATE TOP N A 15 1 22 383 SEAL RADIAL INCLUDED IN A13791 KIT SEE FIGURE 1 2 EXPLODED PUMP VIEW NON FLUSHABL...

Page 20: ...gear binding Maintain the fluid filters according to the instructions from the filter manufacturer If repeated disassembly and cleaning for removal of solids and particu lates occurs inspect the entir...

Page 21: ...chase WRAPPING THE APPLICATOR ASSO CIATED VALVES AND TUBING AND SUPPORTING HARDWARE IN PLASTIC SHRINK WRAP OR ANY OTHER NON APPROVED COVERING WILL VOID THIS WARRANTY RANSBURG S ONLY OBLIGATION UNDER T...

Page 22: ...e Street Angola Indiana 46703 9100 Telephone 260 665 8800 Fax 260 665 8516 Technical Service Assistance 320 Philips Ave Toledo Ohio 43612 1493 Telephone toll free 800 233 3366 Fax 419 470 2233 www ran...

Reviews: