TF2048903-BA-00 English
Page
8
of
16
20180615-V1
back-check feature in the LP tank valve, resulting in some resistance. An additional
one-half to three quarters turn is required to complete connection.
TIGHTEN BY HAND
ONLY
– DO NOT USE TOOLS.
NOTE: If you cannot complete connection, disconnect regulator and repeat step 5 and 6. If
you are still unable to complete the connection,
do not use this regulator!
Disconnecting Regulator to the LP Tank
1. Turn control knob of regulator to the OFF position.
2. Turn LP tank OFF by turning hand wheel clockwise to a
full stop
.
3. Turn the coupling nut counterclockwise to loosen the connector. Loose by hand only
–
do not use tools.
4.
When disconnected, the regulator should be hung on the hook attached to the appliance
.
WARNING
Do not insert any tool or foreign object into the valve outlet or safety relief valve. You may
damage the valve and cause a leak. Leaking propane may result in explosion, fire, severe
personal injury, or death.
Never attempt to attach this appliance to the self-contained LP gas system of a camper or
trailer or motor home.
The pressure regulator and hose assembly supplied with the appliance must be the one
used. Replacement pressure regulator and hose assemblies must be those specified by
the manufacturer.
WARNING
Do not use appliance until leak checked.
If leak is detected at any time, STOP.
If you cannot stop a gas leak, immediately close LP tank valve, leave area of appliance,
and call LP gas supplier or your fire department!
Leak Testing Valves, Hoses and Regulator
1. Turn all control knob(s) to OFF.
2. Be sure regulator is tightly connected to LP tanks.
3. Completely open LP tank valve by turning hand wheel counterclockwise. If you hear a
rushing sound, turn gas off immediately. There is a major leak at the connection. Correct
before proceeding.
4. Brush soapy solution onto indicated connections shown below in A and B. (Reference
connection of hose to burner on page 14.)
5. If
“growing” bubbles appear, there is a leak. Close LP tank valve immediately and
retighten connections. If leaks cannot be stopped, do not try to repair. Call for
replacement parts. Order new parts by giving the serial number, number and name of
items needed to the Customer Service Center at
1
– 888 – 837 – 1380
. Use only
replacement parts specified by manufacturer.
6. Always close LP tank valve after performing tank test by turning hand wheel clockwise.