background image

TF2014501-BA English                                                  Page 9 of 18                                                                  20190107 V.1 

 

 

WARNING 

 

If 

“growing” bubbles appear, do not use or move the LP tank. Contact an LP gas supplier 

or your file department.

 

Connecting Regulator to the LP Tank 

1.  Place LP tank on a secure, level, and stable surface. 
2.  Turn control knob to the OFF position. 
3.  Turn LP tank OFF by turning hand wheel clockwise to a 

full 

stop

4.  Remove the protective cap from the LP tank valve. Always 

use cap and strap supplied with valve. 

 
 
 
 
 
 
 
5.  Hold regulator, insert nipple (B) into LP tank valve. Hand tighten coupling nut, holding 

regulator in a straight line (C) with LP tank valve so as not to cross thread the 
connection. 

 
6.  Turn the coupling nut clockwise to tighten 

to a full solid stop. The regulator will seal 
on the back-check feature in the LP tank 
valve, resulting in some resistance. An 
additional one-half to three quarters turn 
is required to complete connection. 
Tighten by hand only 

– do not use tools. 

NOTE: If you cannot complete connection, 
disconnect regulator and repeat step 5 and 6. 
If you are still unable to complete the 
connection, 

do not use this regulator!

 

 
 
 
 
 
 
 
 
 
 
 
 
 

Do not use a POL transport plug (A) 
(plastic part with external threads)! It 
will defeat the safety feature of the 
valve. 

 

Summary of Contents for TF2014501-BA

Page 1: ...assembling this appliance Leave this manual with this appliance for future reference This instruction manual contains important information necessary for the proper assembly and safe use of the appli...

Page 2: ...eet or 7 5 m of any flammable liquid 4 Do not fill cooking vessel beyond maximum fill line 5 Never allow oil grease to get hotter than 400 F or 200 C If the temperature exceeds 400 F 200 C or if oil b...

Page 3: ...rcial use Safety Symbols The symbols and boxes shown below explain what each heading means Read and follow all of the messages found throughout the manual DANGER Danger Indicates an imminently hazardo...

Page 4: ...er do not remove the lid 8 When cooking with oil or grease have a type BC or ABC fire extinguisher readily available In the event of an oil or grease fire do not attempt to extinguish with water Immed...

Page 5: ...ane Installation Code CSA B1 49 1 This appliance shall be used only outdoors and shall not be used in a building garage or any other enclosed area Use appliance at least 10 ft from any wall or surface...

Page 6: ...e is not intended for and should never be used as a heater Never operate appliance with LP tanks out of correct position specified in assembly instructions Always close LP tank valve and remove coupli...

Page 7: ...t have a safety cap installed as shown Do not store an LP tank in enclosed spaces such as a carport garage porch covered patio or other building Never leave an LP tank inside a vehicle which may becom...

Page 8: ...nies for nearest certified LP dealers LP Tank Exchange Many retailers that sell appliances offer you the option of replacing your empty LP tanks through an exchange service Use only those reputable ex...

Page 9: ...ank valve Hand tighten coupling nut holding regulator in a straight line C with LP tank valve so as not to cross thread the connection 6 Turn the coupling nut clockwise to tighten to a full solid stop...

Page 10: ...eave area of appliance and call LP gas supplier or your fire department Leak Testing Valves Hoses and Regulator 1 Turn all control knob s to OFF 2 Be sure regulator is tightly connected to LP tanks 3...

Page 11: ...the burner and could accidentally ignite with risk of injury Burner Flame Check Light burner rotate knob from HIGH to LOW You should see a smaller flame in LOW position than seen on HIGH Always check...

Page 12: ...spiders are most active These nests can obstruct gas flow and cause a fire in and around the burner and orifice Such a fire can cause operator injury and serious damage to the appliance To help preven...

Page 13: ...combustion and ventilation air Keeping the ventilation opening s of the cylinder enclosed free and clear from debris CAUTION All cleaning and maintenance should only be done when the appliance is cool...

Page 14: ...7 5 Thermometer x 1pc Assembly Procedure 1 Insert the burner into the steel stand and through the cut out opening in the side of the stand 2 Insert the threaded pin on the bottom of the burner into t...

Page 15: ...embly into the burner and tighten Be sure not to strip threads on brass fitting DO NOT OVERTIGHTEN Proper connection is critical for correct operation of unit 4 Attach the handle by inserting 4 bolts...

Page 16: ...e by inserting into a pot of boiling water and ensuring that it registers approximately 212 F 20 F 100 C 10 C If it does not function properly obtain a replacement thermometer specified by the manufac...

Page 17: ...nety 90 days from the date of purchase 5 DAMAGE LIMITATION WARNING IN NO EVENT SHALL MANUFACTURER BE LIABLE FOR ANY INCIDENTIAL OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO LOSS OF USE OF THE...

Page 18: ...r Service Representative s instructions exactly If a return is necessary it must be packed carefully and shipped prepaid Should you encounter any problems CONTACT US FIRST DO NOT return product to the...

Reviews: