19
BATTERY CONFIGURATION
STE
2 House Batteries, 1 Engine Battery, 1 Thruster Battery (optional).
1
1
2
3
3 bank battery charger
Ground/bonding bus
Inverter battery switch
Inverter current breaker (200A)
Thruster battery switch (optional)
Thruster ANL fuse 200A (optional)
HOUSE
ENGINE
EMERGENCY
PARALLEL
STE
House, engine, & battery parallel switches are located in the midberth.
Thruster battery switch is located in the port side lazarette
Inverter battery switch and ANL fuse located in the port side lazarette
Once the EMERGENCY PARALLEL switch is placed in the on position the power from the
HOUSE batteries will be transferred to the ENGINE battery. Use only for EMERGENCY
starting of the engine.
If the house bank drops below 10.8v you must reset the charging relay by switching on
the parallel while the engine is running or while plugged into shore power.
Automatic Charging
Relay (ACR)
House Breaker
Automatic Charging
Relay (ACR)
Downrigger Starboard
Freshwater Switch
Downrigger Port
TV
Washdown Switch
Cabin Light
LED Light Switch
Fridge Foreward
Fridge Aft
Underwater Lights
USB V-Berth
USB Port
40
40
CO Monitor
Stereo Memory
Stove Switch
#1 Float
#2 Float
3
3
1
HOUSE BREAKER
175
Battery Banks
1
= House
2
= Engine
3
= Thruster (optional)