4. Slide the hood assembly over the bracket axle then
secure in place using the 3/8” allen bolt and washer.

5. Raise the hood and hold it up. Use help to hold the hood
while attaching the hood spring. 

Attaching the spring without holding the hood in place may

cause it to snap open suddenly, resulting in personal injury.

6. Hook the other end of the spring over the pin to the rear
of the mounting bracket. Make sure the spring fits into the
grove in the pin.

7. Connect the hood switch wires together as shown.

MOUNTING THE CONTROL TOWER

1. Locate the control tower assembly and remove the
assembly hardware from the parts box.

2. Using help, carefully hold the control tower above the
mounting area on the left side of the cabinet assembly.

3. Locate the wire ribbon coming out of the bottom of the
control tower as well as the wire ribbon near the opening of
the cabinet. 

4. Carefully connect the wire ribbons together making sure
the snap connector is tightly fastened. (Note: The snap
connector may be installed one way only. Do not force
together. If the snap connector does not connect easily, flip
a connector over and try again.)

INSTALLING THE 

THREADED MAIN SHAFT

1. Locate the Threaded Main Shaft and mounting bolt in
the accessory box and install as shown. Be sure to tighten
the bolt firmly.

INITIAL START-UP

1. Turn the balancer ON/OFF switch to ON.

2. A “beep” will be heard three times then the display will
light up. 

3. Press 

START

button. The threaded main shaft should

spin 

CLOCKWISE

when viewed straight on. If the faceplate

spins counterclockwise, turn the balancer off and consult
the factory.

7

Summary of Contents for DST-1500

Page 1: ...tation company at the time shipment is received BE SAFE Your new Ranger balancer was designed and built with safety in mind However your overall safety can be increased by proper training and thoughtf...

Page 2: ...utions in this manual For additional copies or further information contact Bend Pak Inc Ranger Products 1645 Lemonwood Dr Santa Paula CA 93060 1 805 933 9970 www rangerproducts com www bendpak com OPE...

Page 3: ...pplicable Local State and Federal Codes Rules and Regulations such as State and Federal OSHA Regulations and Electrical Codes Carefully check the unit for correct initial function Read and follow the...

Page 4: ...t operate damaged equipment or if the power cord is cut or worn Keep work area clean and well lighted Cluttered and or dark areas invite accidents Avoid dangerous environments Do not use power tools o...

Page 5: ...E MOTOR and can be run on either 110 or 220 volts STANDARD WIRING IS 110 VOLTS Your balancer features a dual voltage 110 220volt dual phase 50 or 60 HZ power system Simply position the switch located...

Page 6: ...ncing Modes Dynamic Static Four Alloy Top Positioning Weight Locator Standard Inside Outside Measuring Standard Millimeter Inches Selection Standard Self Calibration Function Standard Wheel Offset Dis...

Page 7: ...the left side of the cabinet assembly 3 Locate the wire ribbon coming out of the bottom of the control tower as well as the wire ribbon near the opening of the cabinet 4 Carefully connect the wire rib...

Page 8: ...u can determine the diameter of the wheel tire on the tire sidewall to determine the wheel diameter This tells the computer how far from the center of the hub the weights will be applied Balancing a W...

Page 9: ...libration procedure make sure the shaft and centering cones are clean and undamaged Even the slightest dirt or damage can cause inaccurate readings PAY CLOSE ATTENTION to the following procedure If no...

Page 10: ...setting follow the procedures below 1 Press the or button adjacent to to display d in the INNER window 2 Press the STOP then button adjacent to simultaneously Your selection readings will now appear i...

Page 11: ...st the outer wheel hub 5 Spin the hub nut without the pressure cup onto the arbor Tighten securely BALANCING INSTRUCTIONS 1 First determine which mounting method you will use for the wheel 2 Select a...

Page 12: ...wheel and touch the tips against the wheel edges 2 Read the measurement shown on the calipers 3 Press the button adjacent to 4 b will be displayed in the INNER window 5 Press the corresponding buttons...

Page 13: ...tor lights on the side marked OUTER are fully illuminated This indicates the position specified by the balancer for the OUTER weight position 7 Attach the specified weight for the CENTER PLANE positio...

Page 14: ...al weight readings will appear in the display windows STOP BUTTON The STOP button IS NOT an emergency stop button It will not immediately shut down shaft and wheel rotation For emergency situations th...

Page 15: ..._______ _______________________________________________ _______________________________________________ _______________________________________________ _______________________________________________...

Page 16: ...16...

Page 17: ...17...

Page 18: ...18...

Page 19: ...19...

Page 20: ...For Parts Or Service Contact Bend Pak Inc Ranger Products 1645 Lemonwood Dr Santa Paula CA 93060 Tel 1 805 933 9970 Fax 1 805 933 9160 www bendpak com www rangerproducts com...

Reviews: