32
12. Technical Data
THIS COOKER IS CATEGORY
: C.
It is supplied set for group H natural gas. A conversion kit from NG to LP is available for the cooker.
INSTALLER:
Please leave these instructions with the User.
DATA BADGE LOCATION:
Cooker back, serial number repeater badge below oven door opening.
COUNTRY OF DESTINATION:
GB, IE.
Connections
Gas
(Rp ½ at rear right-hand side)
Electric
Natural Gas
20 mbar
230/400 V 50 Hz
Butane
29 mbar
Propane
37 mbar
Dimensions
Model
Elise 90 Dual Fuel
Overall height
minimum 910 mm
maximum 935 mm
Overall width
900 mm
Overall depth
598 mm excluding handles, 650 mm including handles
Minimum height above the hotplate
650 mm
Refer to ‘Positioning the Cooker’.
Ratings
Hotplate
Bypass Screw*
Natural Gas 20 mb
LP Gas
Injector
Injector
Wok burner
57
3.5 kW
internal 78
3.5 kW (246 g/h)
internal 53
external 126
external 82
Large burner
40
3.0 kW
134
3.0 kW (210 g/h)
87
Medium burner
32
1.7 kW
109
1.7 kW (119 g/h)
68
Small burner
28
1.0 kW
75
1.0 kW (70 g/h)
51
* The valves in this cooker are fitted with adjustable bypass screws. The cooker is supplied with the bypass screws set for Natural gas. For LPG conversion the
bypass screws must be screwed all the way down.
Hotplate energy saving tips
Oven energy saving tips
Use cookware with a flat base.
Cook meals together, if possible.
Use the correct size cookware.
Keep the pre-heating time short.
Use cookware with a lid.
Do not lengthen cooking time.
Minimise the amount of liquid or fat.
Do not open the oven door during the cooking period.
When liquid starts boiling, reduce the setting.
Do not forget to turn the appliance off at the end of cooking.
Consumption is based on G30.
DocNo.107-0023 - Technical data - 110DF - Classic DL