INSTALLATION

Wall drilling and bracket fixing 

11a

1

1

2

2

140

11

12a

164 164

788

540

450

140

X

1÷2

7.2.1

As a first step, proceed with the following drawings: 

•  a vertical line up to the ceiling or up to the upper limit, at the centre of

 the area in which the 

hood is to be fitted; 

•  a horizontal line at a minimum  788 mm above the cooker top.  

•  Mark a point 

(1)

 on the horizontal line, 164 mm to the right of the vertical reference line.  

•  Repeat this operation on the other side, checking that the two marks are levelled. 

•  Mark a reference point 

(2)

 as indicated at 140 mm from the vertical reference line and 540 

mm above the cooker top. 

•  Repeat this operation on the other side, checking that the two marks are levelled. 

•  Drill at the marked points 

(1)

, using a ø 12 mm drill bit. 

•  Drill at the marked points 

(2)

 using a ø 8 mm drill bit.  

•  Insert the bracket plugs 

11a

 into the holes (

1)

 and tighten the screws. 

•  Insert plug 

11

 into holes 

(2)

.

To install a decorative chimney ( optional )

•  Place  bracket 

7.2.1

  on  the  wall,  about  1-2  mm  from  the  ceiling  or  from  the  upper  limit, 

aligning the centre (notch) with the vertical reference line.  

•  Mark the wall at the centres of the bracket holes. 

•  Place the bracket 

7.2.1

 on the wall at X mm below the first bracket (X = height of the upper 

chimney section), aligning the centre (notch) with the vertical line. 

•  Mark the wall at the centres of the bracket holes. 

•  Drill ø 8 mm holes at all the marked centre points. 

•  Insert the wall plugs 

11

 in the holes. 

•  Fix the brackets using the 

12a

 screws (4,2 x 44,4) supplied with the hood. 

Summary of Contents for OPLHD100

Page 1: ...OPLHD60 OPLHD90 OPLHD100 OPAL HOOD Instructions Manual www rangemaster co uk ...

Page 2: ...2 2 INDEX RECOMMENDATIONS AND SUGGESTIONS 3 CHARACTERISTICS 4 INSTALLATION 5 USE 8 MAINTENANCE 9 EN ...

Page 3: ...llationforthegashobspecifyagreaterdistancespecifiedabove thishas tobetakenintoaccount Regulationsconcerningthedischargeofairhavetobefulfilled USE Theextractorhoodhasbeendesignedexclusivelyfordomesticusetoeliminatekitchensmells Neverusethehoodforpurposesotherthanforwhichithasbeendesigned Neverleavehighnakedflamesunderthehoodwhenitisinoperation Adjust the flame intensity to direct it onto the bottom...

Page 4: ...2 2 1 Lower Section 8 1 Directional Air Outlet grille 9 1 Reducer Flange ø 150 120 mm 10 1 Adapting ring ø 120 125 mm 15 1 Angle iron 16 1 Filter cover Ref Q ty Installation Components 7 2 1 2 Upper Chimney Section Fixing Brackets 11 6 Wall Plugs 11a 2 Wall Plugs SB 12 10 12a 6 Screws 4 2 x 44 4 12c 10 Screws 2 9 x 6 5 12d 6 Screws 2 9 x 9 5 Q ty Documentation 1 Instruction Manual 5 ...

Page 5: ...her side checking that the two marks are levelled Drill at the marked points 1 using a ø 12 mm drill bit Drill at the marked points 2 using a ø 8 mm drill bit Insert the bracket plugs 11a into the holes 1 and tighten the screws Insert plug 11 into holes 2 To install a decorative chimney optional Place bracket 7 2 1 on the wall about 1 2 mm from the ceiling or from the upper limit aligning the cent...

Page 6: ...en the safety screw 12a Close the doors the door again 12a Vr 11a Connections DUCTED VERSION AIR EXHAUST SYSTEM When installing the ducted version connect the hood to the chimney using either a flexible or rigid pipe ø 150 or 125 mm the choice of which is left to the installer To install a ø 125 mm air exhaust connection insert the reducer flange 9 on the hood body air outlet and the adapting ring...

Page 7: ...aph Maintenance being sure that the connector of the feeding cable is correctly in serted in the socket placed on the side of the fan Flue assembly The chimney can only be installed with exhausting hood Fasten the angle iron 15 to the hood canopy using the screws 12d 2 9 x 9 5 provided Upper exhaust flue Slightly widen the two sides of the upper flue and hook them behind the brackets 7 2 1 making ...

Page 8: ...ble to change the op erating speed when this function is enabled The respective buttons T1 T2 or T3 or T4 will flash T4 Turns the Motor on at speed three Buttons T1 T4 are on Press and hold for 2 seconds to activate Intensive speed which is timed to run for 10 minutes At the end of this time it will automatically return to the speed set before Suitable to deal with maximum levels of cooking fumes ...

Page 9: ...ly for particularly heavy usage and can be washed in a dishwasher Pull the comfort panels to open them Remove the filters one by one pushing them towards the back side of the hood unit and simultaneously pulling downwards Any kind of bending of the filters has to be avoided when washing them Before fitting them again into the hood make sure that they are completely dry The colour of the filter sur...

Page 10: ... metal grease filters Remove the saturated activated charcoal filter as shown A Fit the new filters B Replace the metal grease filters Close the comfort panels A B Lighting unit Warning This appliance is fitted with a white LED lamp classed as 1M according to EN 60825 1 1994 A1 2002 A2 2001 standards maximum optical power emitted 439nm 7µW Do not look directly at the light through optical devices ...

Page 11: ......

Page 12: ...991 0301 958_ver4 AGA RANGEMASTER GROUP PLC ...

Reviews: