CHARACTERISTICS

 

Dimensions 

 

650 min.

200

100

ø150

698 - 898

190

240

30

90

55

r 58

492

360

min 560

max 760

 

Components 

Ref. Q.ty 

Product Components 

1 

1  Hood Body, complete with: Controls, Light, Blower, 

Filters 

2 

Telescopic Chimney comprising: 

2.1 1 

Upper 

Section 

2.2 1 

Lower 

Section 

8a 

Right Air Outlet Grill 

8b 

Left Air Outlet Grill 

9 

Reducer Flange ø 150-120 mm 

10 

Adapting ring ø 120-125 mm 

15 

Air Outlet Connection 

17 

Lower Chimney Fixing Bush

 

Ref. Q.ty 

Installation Components 

7.1 

Hood Body Fixing Brackets 

7.2.1 

Upper Chimney Section Fixing Brackets 

11 8 

Wall 

Plugs 

12a 

Screws 4.2 x 44,4 

12c 

Screws 2.9 x 9.5 

12d 

Screws M4 x 25 

 Q.ty 

Documentation 

 1 

Instruction 

Manual 

 

11

17

9

12e

1

7.1

7.2.1

12a

11

12a

12e

12d

2.1

2.2

2

8b

8a

15

10

 

Summary of Contents for LEIHDC70BB

Page 1: ...LEIHDC70SC LEIHDC70BB LEIHDC70BC Instructions Manual www rangemaster co uk...

Page 2: ...2 2 INDEX RECOMMENDATIONS AND SUGGESTIONS 3 CHARACTERISTICS 4 INSTALLATION 5 USE 8 MAINTENANCE 9 EN...

Page 3: ...r than for which it has been designed Never leave high naked flames under the hood when it is in operation Adjust the flame intensity to direct it onto the bottom of the pan only making sure that it d...

Page 4: ...on 8a 1 Right Air Outlet Grill 8b 1 Left Air Outlet Grill 9 1 Reducer Flange 150 120 mm 10 1 Adapting ring 120 125 mm 15 1 Air Outlet Connection 17 2 Lower Chimney Fixing Bush Ref Q ty Installation Co...

Page 5: ...ace bracket 7 1 as shown 120 mm from the vertical reference line and 175 mm above the horizontal reference line Mark the centres of the holes in the bracket Repeat this operation on the other side REA...

Page 6: ...chimney using either a flexible or rigid pipe 150 or 125 mm the choice of which is left to the installer To install a 125 mm air exhaust connection insert the re ducer flange 9 on the hood body air ou...

Page 7: ...ng the 4 screws 12e 2 9 x 9 5 supplied Lower exhaust flue Insert the lower flue fixing bush 17 in the top of the hood body and rotate it 90 clockwise as far as it will go Slightly widen the two sides...

Page 8: ...s the operating speed of the extractor 1 Low speed used for a continuous and silent air change in the presence of light cooking vapour 2 Medium speed suitable for most operating conditions given the o...

Page 9: ...irculation version These filters are not washable and cannot be regenerated and must be replaced approximately every 4 months of operation or more frequently with heavy usage REPLACING THE ACTIVATED C...

Page 10: ......

Page 11: ......

Page 12: ...4329645_ver7 AGA RANGEMASTER GROUP PLC...