Mounting the hood body
• Hook the hood body onto the screws
12a
.
• Fully tighten the support screws
12a
.
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the
chimney using either a flexible or rigid pipe ø 150 or 125
mm, the choice of which is left to the installer.
• To install a ø 125 mm air exhaust connection, insert the
reducer flange
9
on the hood body air outlet and the adapt-
ing ring ø120-125
10a
on the reducer flange.
• Fix the pipe in position using sufficient pipe clamps (not
supplied).
• Remove any activated charcoal filters.
9
ø 125
10
ø 150
RECIRCULATION VERSION AIR OUTLET
• Push fit the air outlet fitting
15
onto the air outlet of the
hood body.
• Ensure that the activated charcoal filters have been in-
serted.
15