background image

EN 

7

INSTALLATION

 

Wall drilling and bracket fixing 

Wall marking: 
• Draw a vertical line on the supporting wall up to the ceiling, or as high as practical, at the

centre of the area in which the hood will be installed.

• Draw a horizontal line at 650 mm above the hob.
• Place bracket 

7.2.1

 on the wall as shown about 1-2 mm from the ceiling or upper limit align-

ing the centre (notch) with the vertical reference line.

• Mark the wall at the centres of the holes in the bracket.
• Place bracket 

7.2.1

 on the wall as shown at X mm below the first bracket (X = height of the

upper chimney section supplied), aligning the centre (notch) with the vertical line.

• Mark the wall at the centres of the holes in the bracket.
• Mark a reference point as indicated at 116 mm from the vertical reference line and 320 mm

above the horizontal reference line.

• Repeat this operation on the other side.
• Drill ø 8 mm holes at all the centre points marked.
• Insert the wall plugs 

11

 in the holes.

• Fix the brackets 

7.2.1

  using the 

12a

 screws (4,2 x 44,4) supplied.

• Fix the Hood Body Fixing Brackets

 7.1

 using the 2 screws 

12a

 (4,2 x 44,4) and Washers

 22

supplied, checking levelling.

320

Summary of Contents for HI-LITE HLTHDS90

Page 1: ...HI LITE HOOD HLTHDS90 HLTHDS100 HLTHDS110 Instructions Manual...

Page 2: ...2 2 INDEX SAFETY INFORMATION 3 CHARACTERISTICS 6 INSTALLATION 7 USE 10 CARE AND CLEANING 11 EN...

Page 3: ...eight please refer to the paragraphs on working dimensions and installation If the instructions for installation for the gas hob specify a greater distance this must be respected Check that the mains...

Page 4: ...to be adopted for fume discharging it is important to closely follow the regulations pro vided by the local authorities WARNING Before installing the Hood remove the protective films Use only screws a...

Page 5: ...ls not applicable to appliances that only discharge the air back into the room The symbol on the product or on its packaging indicates that this product may not be treated as household waste Instead i...

Page 6: ...1 Telescopic Chimney comprising 2 1 1 Upper Section 2 2 1 Lower Section 9 1 Reducer Flange 150 120 mm 15 1 Air Outlet Connection Ref Q ty Installation Components 7 1 1 Hood Body Fixing Brackets 7 2 1...

Page 7: ...Place bracket 7 2 1 on the wall as shown at X mm below the first bracket X height of the upper chimney section supplied aligning the centre notch with the vertical line Mark the wall at the centres o...

Page 8: ...body outlet Fix the pipe in position using sufficient pipe clamps not sup plied Remove possible charcoal filters 9 120 150 Exhausted mode Recommendations and suggestions Connect the extractor to the e...

Page 9: ...grease filters see paragraph Maintenance be ing sure that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan Flue assembly Upper exhaust flue Slightl...

Page 10: ...ble to change the op erating speed when this function is enabled The respective buttons T1 T2 or T3 or T4 will flash T4 Turns the Motor on at speed three Buttons T1 T4 are on Press and hold for 2 seco...

Page 11: ...ng When refitting the filters make sure that the handle is visible on the outside Activated charcoal filter Recirculation version REPLACING THE ACTIVATED CHARCOAL FILTER The filter is not washable and...

Page 12: ......

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...991 0388 012_ver5 190514 D00001441_04 AGA RANGEMASTER GROUP PLC...

Reviews: