CARE AND CLEANING

 

Grease filters 

CLEANING METAL SELF- SUPPORTING GREASE FILTERS 

•  The filters must be cleaned every 2 months of operation, or 

more frequently for particularly heavy usage, and can be 
washed in a dishwasher. 

•  Remove the filters one at a time by pushing them towards the 

back of the group and pulling down at the same time.  

•  Wash the filters, taking care not to bend them. Allow them to 

dry before refitting. 

•  When refitting the filters, make sure that the handle is visible 

on the outside.

 

 

 

Activated charcoal filter (Recirculation version) 

REPLACING THE ACTIVATED CHARCOAL FILTER 

•  The filter is not washable and cannot be regenerated, and must 

be replaced approximately every 4 months of operation, or 
more frequently for particularly heavy usage. 

•  Remove the metal grease filters. 
•  Remove the saturated activated carbon filter by releasing the 

fixing hooks. 

•  Fit the new filter by hooking it into its seating. 
•  Refit the metal grease filters.

 

 

 

Lighting unit 

• For replacement contact technical support ("To purchase 

contact technical support").

 

 

 

Summary of Contents for HI-LITE HLTHDS90

Page 1: ...HI LITE HOOD HLTHDS90 HLTHDS100 HLTHDS110 Instructions Manual...

Page 2: ...2 2 INDEX SAFETY INFORMATION 3 CHARACTERISTICS 6 INSTALLATION 7 USE 10 CARE AND CLEANING 11 EN...

Page 3: ...eight please refer to the paragraphs on working dimensions and installation If the instructions for installation for the gas hob specify a greater distance this must be respected Check that the mains...

Page 4: ...to be adopted for fume discharging it is important to closely follow the regulations pro vided by the local authorities WARNING Before installing the Hood remove the protective films Use only screws a...

Page 5: ...ls not applicable to appliances that only discharge the air back into the room The symbol on the product or on its packaging indicates that this product may not be treated as household waste Instead i...

Page 6: ...1 Telescopic Chimney comprising 2 1 1 Upper Section 2 2 1 Lower Section 9 1 Reducer Flange 150 120 mm 15 1 Air Outlet Connection Ref Q ty Installation Components 7 1 1 Hood Body Fixing Brackets 7 2 1...

Page 7: ...Place bracket 7 2 1 on the wall as shown at X mm below the first bracket X height of the upper chimney section supplied aligning the centre notch with the vertical line Mark the wall at the centres o...

Page 8: ...body outlet Fix the pipe in position using sufficient pipe clamps not sup plied Remove possible charcoal filters 9 120 150 Exhausted mode Recommendations and suggestions Connect the extractor to the e...

Page 9: ...grease filters see paragraph Maintenance be ing sure that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan Flue assembly Upper exhaust flue Slightl...

Page 10: ...ble to change the op erating speed when this function is enabled The respective buttons T1 T2 or T3 or T4 will flash T4 Turns the Motor on at speed three Buttons T1 T4 are on Press and hold for 2 seco...

Page 11: ...ng When refitting the filters make sure that the handle is visible on the outside Activated charcoal filter Recirculation version REPLACING THE ACTIVATED CHARCOAL FILTER The filter is not washable and...

Page 12: ......

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...991 0388 012_ver5 190514 D00001441_04 AGA RANGEMASTER GROUP PLC...

Reviews: