background image

All features & specifications subject to change without notice. 520-258  JUL94

©Rane Corporation 10802 47th Avenue West, Mukilteo WA 98275-5098  TEL(206) 355-6000  FAX(206) 347-7757

easy by using the 

MEMORY

 button when in the EQ Edit

mode. All changes to the Working Memory are compared
with the Stored Memory by pressing and holding the

MEMORY

 button. The letter

C

C

 appears on the 

EQUALIZER

display indicating a compare function is being performed.
While the 

MEMORY

 button is held, what is heard is the

Stored Memory curve—releasing the 

MEMORY

 button

allows you to hear the edited Working Memory version.

USING STORED CURVES.

 To use any of the curves in

Stored Memory, all you do is show the Stored Memory
location on the red 

SYSTEM

 display. Whatever number

shows is the label of the Stored Memory location for the
current Working Memory.

Working Memory is the scratch pad where you work. You

can think of it as the

129

th memory location (like the 19th

hole in golf), except you cannot actually store anything
here—only operate on it, or listen to it. When a Stored
Memory location shows up on the 

SYSTEM

 display, the

curve is actually in two locations: safely stored at the memory
location shown 

and

 in the Working Memory scratch pad,

ready for you to change if you want. You can do anything
you want to the Working Memory without altering the
original stored version. When complete, you must store this
new version either in place of the old curve, or into a new
location. This is the significance of the 

MEMORY

 light

blinking. Once you do anything to the original curve, the

MEMORY

 light starts blinking to remind you it changed.

If you want a different curve, press the 

UP/DOWN

buttons to scroll, or directly enter a number via buttons 

0

through 

9

 (observe the red 

SYSTEM

 display). Please note

that all Stored Memory numbers must be at least two digits;
e.g., Stored Memory number

4

 is entered as 

04

, etc. For direct

access to Stored Memory locations above 

99

, push the 

100

button, then the next two digits. For example, to recall stored
memory

125

, press 

100

2

 and 

5

. Once the last digit is

entered, the program is instantly called up (what you see is
what you hear). What could be simpler?

BYPASS MODE.

 Pressing either 

BYPASS 1 or 2

 causes

all audio in the selected Channel to be routed around the
equalizer electronics. Please note that a bypassed condition
cannot be stored. If recalling a flat curve is required, simply
store a program in which all filter and level controls are set to
zero (Factory Preset

1

, if it has not been overwritten in Stored

Memory).

MIDI CHANNEL.

 Pressing the 

CHANNEL

 button

displays the currently assigned MIDI Channel. Pressing 

UP/

DOWN

 increases or decreases the MIDI Channel number.

You may select from

1

 through

16

, or

OFF

.

MIDI CONTROL. T

he MPE 14 can be controlled by

another MPE, an RPS 4 Remote Program Switch (contact
closure to MIDI Program Change converter), personal
computer, or any device capable of transmitting MIDI. A
DOS program is available from the factory by request. Details
are, you guessed it, in the

 MPE Users Guide.

OTHER FEATURES.

 To say the MPE 14 does a lot

more than explained in this brief space is like saying a
personal computer makes a good paperweight. Please read the

MPE Users Guide

 for a more in-depth look at your MPE 14.

POWER SUPPLY.

 As noted elsewhere in this manual,

NEVER USE A POWER SUPPLY WITH YOUR MPE 14
OTHER THAN THE ONE SUPPLIED FROM THE FACTORY
OR AN EXACT REPLACEMENT FROM RANE CORPORA-
TION.

 

The MPE 14’s power supply input is designed for an

AC supply, delivering 18-24 volts, from a center-tapped
transformer capable of supplying at least the current de-
manded by this product. Using any other type of supply may
damage the equalizer and void the warranty (which at two
years parts and labor is worth safeguarding, don’t you think?).

Additional information and full technical specifications

will be found on the enclosed 

MPE 14 Data Sheet

.

FCC & VDE NOTICE

This equipment has been tested and found to comply

with the limits for a Class A digital device, pursuant to
Part 15 of the FCC Rules, and similar requirements found
in European specifications VDE 0871/0875. These limits
are designed to provide reasonable protection against
harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses,
and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction
manual, may cause harmful interference to radio commu-
nications. Operation of this equipment in a residential area
is likely to cause harmful interference in which case the
user will be required to correct the interference at their
own expense. 

USE OF SHIELDED MIDI CABLES IS

REQUIRED FOR FCC COMPLIANCE.

CHASSIS GROUNDING

The unit is shipped with its Ground Lift switch in the

CHASSIS GND

 position. This ties signal ground to

chassis ground. If after hooking up your system it exhibits
excessive hum or buzzing, there is an incompatibility in
the grounding configuration between units. Here are some
things to try:

1. Try combinations of lifting grounds on units

supplied with Ground Lift switches (or links).

2. Verify all chassis are tied to a good earth ground.
3. Units with outboard power supplies do 

not

 ground

the chassis through the line cord. Make sure these units
are solidly grounded by tying the Chassis Ground Point to
known earth ground (such as a power amplifier chassis).
Use a star washer to guarantee proper contact.

SOFTWARE UPDATES

Please fill out and mail in the enclosed registration card.

Notification of any software revisions will be mailed to all

registered

 users. Failure to register could result in missing

important update information.

IMPORTANT NOTE

Reviews: