Compliance Notices

FCC Notice

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the

FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy, and if not
installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Opera-
tion of the equipment in a residential area is likely to cause harmful interference in which case the user will be required to
correct the interference at their own expense. Changes or modifications not expressly approved by Rane Corporation could void
the user’s authority to operate the equipment.

Canadian EMC Notice

This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet

Appariel numerique de la classe B respecte toutes les exigences du Reglement sur le material broilleur du Canada.

FCC Part 68 - Compliance

FCC Part 68 Registration Number: 6PV USA-35030-BR-T

Ringer Equivalence Number (REN): 0.1B

This equipment complies with Part 68 of the FCC rules. The FCC Part 68 registration number and Ringer Equivalence Number
(REN) is posted on the rear of the equipment. This information must be provided to your telephone company, if requested.

USOC Jacks: This product uses RJ11C type terminal jacks.

The quantity of devices which may be connected to a telephone line and still operate properly is determined by REN. An
excessive number of RENs connected to a telephone line may result in devices not ringing to an incoming call. Typically, the
number of RENs should not exceed five. Consult with you telephone company to obtain the maximum RENs for your area.

Should this equipment cause harm the telephone network, the telephone company will notify you in advanced that temporary

disconnect of service might be required. If it is not practical for the Telephone Company to give an advanced notice, they will
notify the customer as soon as possible. In addition, you will be advised of your right to file a complaint with the FCC.

It is possible that the Telephone Company may make changes to their equipment, operations, facilities and/or procedures that

could affect the operation of this equipment. Should this happen, the telephone company will provide advance notice of such
changes for you to make the necessary modifications in your equipment.

If this equipment is causing problems, contact Rane Corporation, 10802 47

th

 Avenue West, Mukilteo, WA 98275,  (425) 355-

6000 for repair and warranty information. The Telephone Company may instruct you to remove the equipment from the network
until the problem is resolved.

No user serviceable parts are contained within this product. If problems occur, contact Rane Corporation for service.

Use of this equipment is prohibited on Telephone Company provided coin service. Connecting to Party Line service is subject to
State tariffs.

IC Compliance

IC Certification Number: 3614 10632 A

Ringer Equivalence Number (REN): 0.1B;

Standard Connecting Arrangement RJ11C

Notice:

 The Industry of Canada label identifies certified equipment that meets certain telecommunications network stan-

dards, including protective operation and safety requirements, as prescribed in the appropriate Terminal Equipment Technical
Requirements documents(s). By this label, The Industry of Canada does not guarantee the equipment will operate to the user’s
satisfaction.

Before connecting this equipment to the telephone network, the user should ensure that the equipment is acceptable to the

local Telephone Company. An acceptable method of connecting to the telephone network must be followed. All electrical
ground connections of the power utilities, metal water pipes, and telephone lines must be connected together. Proper grounding
precaution may be particularly important in rural areas. Extending the telephone service of a single line may be accomplished by
means of a certified telephone extension cord.  In addition, extension of telephone service must not degrade the telephone
service.

Caution:

  Users should not attempt to make such connections themselves, but should contact the appropriate electric

inspection authority, or electrician, as appropriate.

Repairs of Industry of Canada certified equipment must be performed by an authorized Canadian service facility specified by

Rane Corporation. Unauthorized user modifications or repairs to this equipment may result in the Telephone Company request-
ing that the user disconnect the equipment from the telephone service.

NOTICE:

 The 

Ringer Equivalence Number (REN) 

assigned to each terminal device provides an indication of the maxi-

mum number of terminals allowed to be connected to a telephone interface.  The termination on an interface may consist of any
combination of devices subject only to the requirement that the sum of the Ringer Equivalence Numbers of all the devices does
not exceed five.

All features & specifications subject to change without notice. 104477

©Rane Corporation  10802 47th Ave. W.,  Mukilteo WA 98275-5098  TEL (425)355-6000  FAX (425)347-7757  WEB http://www.rane.com

Summary of Contents for ECM 64e

Page 1: ...SS switch to 1 by setting all switches off down except switch one labeled 1 on the chassis the right most switch If there is more than one unit refer to Setting the Device Address on page Manual 7 to...

Page 2: ...ECM 64e has been placed in Auto Answer and will accept an incoming call when the number of rings matches the set ring count LEVEL meter Selectively displays any one of the inputs or outputs by using...

Page 3: ...acks magically appear when the DH 1e is installed included with the ECM 64eAD The PHONE jack connects to a standard two wire POTS telephone This connection is disconnected when the ECM 64e is Off Hook...

Page 4: ...nce Out 1 is used for the AEC Reference Mics cannot be sent to Out 1 for local speech reinforcement If Mics are sent to both the AEC Input and the AEC Reference the AEC will not perform properly The M...

Page 5: ...Manual 5 Wiring Digram for Typical ECM 64eAD Installation AP1 C64 RaneWare Screens...

Page 6: ...t line to the telephone company s CO Central Office This line should not be shared by others as this may cause ground loops ECM 64e Connection Overview Balanced Euroblock audio connections are used th...

Page 7: ...Address The Device Address is set using a binary code which may be determined using the following table our Windows Address Calculator program or by adding the place values 1 15 silk screened on the...

Page 8: ...dware Manual RaneWare can be fully demonstrated and operated without any unit attached called offline A RaneWare CD ROM comes with each unit RaneWare is a single program with different windows capable...

Page 9: ...Memory not to the selected Memory The selected Memory flashes whenever working Memory does not match it To save these settings in one of the 16 Memories simply click Store and the Memory number key Af...

Page 10: ...by subtracting the room loudspeaker audio from audio received by the room microphones This is accomplished by routing the room loudspeaker audio to the AEC Reference REF and room microphones to the AE...

Page 11: ...Answer and Ring Detect Auto Disconnect Off Hook status DTMF Dialing with six programmable speed numbers DTMF Decoding See Opstat page Manual 19 You can check the status of the digital hybrid in Devic...

Page 12: ...olling for units in RaneWare under Device Poll The unit should be found quickly Check that the COM port selected in RaneWare under Setup System Setup is the one on your computer that is con nected to...

Page 13: ...ller opera tion DH 1e Digital Hybrid The DH 1e Digital Hybrid allows audio conferencing over a standard POTS 2 wire phone line A 32 millisecond Line Echo Canceller is utilized to remove line echo caus...

Page 14: ...informs you he only has enough audio budget for 2 ECM 82As Before telling your client there is no way here is a solution Since the ECM 64e has 4 Mic Inputs use these for the speech reinforcement mics...

Page 15: ...Manual 15 ECM 64e and Larger ECS Installation...

Page 16: ...On 0 Off 8 08 AEC In Mic Mix 1 0 byte 1 On 0 Off 9 09 AEC In Line 1 0 byte 1 On 0 Off 10 0A AEC In Aux 1 0 byte 1 On 0 Off 11 0B AEC Ref Mix In Out1 Ext 0 1 2 byte 0 Mix In 1 Out 1 2 Ext 12 0C AEC Ref...

Page 17: ...33 Phone Level 0 to 31 byte 15 to 16 dB 52 34 Noise Level 0 to 31 byte 15 to 16 dB Output 3 Parameters Index Hex Name System Parameters Encoding Method 53 35 Output Mute 1 0 byte 1 Mute 54 36 Output L...

Page 18: ...X Overflow 09 RW232 Parity Error 0A Not Ready 0B Flash Error Send data to channel 81 hex Transmit ADDR header FB XX FB XX where XX ADDR See Note 9 Get DT Get ID Transmit 00 XX where XX number of data...

Page 19: ...ecksum Get COMSTAT Mute Output 87 hex Transmit ADDR header FB XX FB XX where XX ADDR See Note 9 Get DT Get ID Transmit 00 03 where 03 number of data bytes to follow including checksum Transmit 87 comm...

Page 20: ...1 20 39 14 27 DTMF Number 2 40 59 28 3BDTMF Number 3 60 79 3C 4FDTMF Number 4 80 99 50 63 DTMF Number 5 100 119 64 77 DTMF Number 6 A within the DTMF number inserts a 500 millisecond delay A non digi...

Page 21: ...Hybrid Command 92 hex Transmit ADDR header FB XX FB XX where XX ADDR See Note 9 Get DT Get ID Transmit 00 XX where XX number of data bytes to follow including checksum Transmit 92 command code Transm...

Page 22: ...data bytes to follow including checksum Transmit 00 command code Transmit FE checksum Get Data From Channel 01 hex Transmit ADDR header FB XX FB XX where XX ADDR See Note 9 Get DT Get ID Transmit 00...

Page 23: ...ecksum Get Hardware Revision Get Software Revision x10 Get Checksum for both revisions Get COMSTAT Get MRP Table 0B hex Transmit ADDR header FB XX FB XX where XX ADDR See Note 9 Get DT Get ID Transmit...

Page 24: ...lize hardware handshaking via DTR DSR The beginning of a message always takes the form FB xx FB xx where xx ADDR Note When FB appears in the body of the message it is always repeated Input port 9 pin...

Page 25: ...the one byte Command and any Data int CmdToPacket BYTE Buff int MsgLen BYTE L_MSB MsgLen 1 8 0xFF Grab MSB of Size BYTE L_LSB MsgLen 1 0xFF Grab LSB of Size FBs is the number of 0xFB bytes in the mes...

Page 26: ...n your equipment If this equipment is causing problems contact Rane Corporation 10802 47th Avenue West Mukilteo WA 98275 425 355 6000 for repair and warranty information The Telephone Company may inst...

Reviews: