background image

23

22

21

MALE

(A

NY UNBALANCED C

ONNEC

TOR)

(A

NY UNBALANCED C

ONNEC

TOR)

(CHECK

: NO ST

AND

ARD POLARIT

Y ON EUROBL

OCKS)

(CHECK

: NO ST

AND

ARD POLARIT

Y ON EUROBL

OCKS)

20

19

18

17

16

15

MALE

A

14

13

MALE

A

A

A

A

A

1

3

2

1

2

3

1

2

3

To Input

From Output

S=SHIELD

R=BLA

CK

T=RED

S=SHIELD

R=BLA

CK

T=RED

S=SHIELD

R=BLA

CK

T=RED

S=SHIELD

R=BLA

CK

T=RED

S=SHIELD

R=BLA

CK

T=RED

23

S=BLA

CK

T=RED

S=BLA

CK

T=RED

S=BLA

CK

T=RED

S=BLA

CK

T=RED

S=SHIELD

T=RED

S=SHIELD

T=RED

S=SHIELD

T=RED

S=SHIELD

T=RED

S=SHIELD

T=RED

S=SHIELD

T=RED

S=SHIELD

T=RED

S=SHIELD

T=RED

3=BLA

CK

2=RED

1=SHIELD

3=BLA

CK

2=RED

1=SHIELD

3=BLA

CK

2=RED

1=SHIELD

SHIELD

BLA

CK

SHIELD

RED

BLA

CK

SHIELD

RED

BLA

CK

RED

SHIELD

SHIELD

BLA

CK

RED

SHIELD

BLA

CK

RED

SHIELD

BLA

CK

RED

SHIELD

BLA

CK

RED

SHIELD

BLA

CK

RED

SHIELD

RED

SHIELD

RED

SHIELD

RED

SHIELD

RED

BLA

CK

RED

N/C

N/C

BLA

CK

RED

BLA

CK

RED

BLA

CK

RED

RED

SHIELD

RED

SHIELD

RED

SHIELD

RED

24

S=BLA

CK

T=RED

CROSS

-C

OUPLED OUTPUT ONL

Y:

 C

ONNEC

T BLA

CK 

TO

 SHIELD 

AT

 THIS END

AND SE

T GROUND LIFT SWIT

CH 

TO

 ‘G

ROUNDED

’ (IF PRESENT

).

BLA

CK

SHIELD

RED

BLA

CK

RED

2-

CONDUC

TOR SHIELDED CABLE

2-

CONDUC

TOR SHIELDED CABLE

2-

CONDUC

TOR SHIELDED CABLE

2-

CONDUC

TOR SHIELDED CABLE

S=BLA

CK

T=RED

SHIELD

BLA

CK

RED

BLA

CK

RED

2-

CONDUC

TOR SHIELDED CABLE

2-

CONDUC

TOR SHIELDED CABLE

2-

CONDUC

TOR SHIELDED CABLE

2-

CONDUC

TOR SHIELDED CABLE

1-

CONDUC

TOR SHIELDED CABLE

1-

CONDUC

TOR SHIELDED CABLE

1-

CONDUC

TOR SHIELDED CABLE

1-

CONDUC

TOR SHIELDED CABLE

+

+

From Output

To Input

Summary of Contents for BB 22

Page 1: ...rd and paper Cartons et papier à recycler Contents Features 2 General Description 2 BB 22 Application Information 3 BB 22 Specifications 4 Designator Drawing 5 Block Diagram 6 Schematic 7 Sound System Interconnection 8 Warranty 24 11259 ...

Page 2: ...For instance a BB 22 may be mounted to the back of a jukebox converting its unbalanced outputs to balanced lines feeding an amplifier in another room Signal to noise performance is perfectly preserved using the BB 22 since it uses only passive transformers to convert signal levels It adds no additional noise whatsoever Use of professional quality nickel core 80 Ni transform ers guarantee low disto...

Page 3: ...kΩ load winds up looking like 1 kΩ to the equipment with the 10 dBV output due to transformer action This may seem excessively low but is not in practice The maximum transformer output level of 24 dBu occurs with an input level of 10 dBV which equals 3 16 volts And 3 16 volts driving 1 kΩ only requires 3 16 milliamps which is a very modest requirement for any 10 dBV equipment to deliver Wiring The...

Page 4: ...s Shown 10 dBV 1k 5 Ω Load impedance 15k Ω Insertion Loss 0 5 0 1 dB With recommended load impedance DC Resistance 47 5 200 10 Ω 10 dBV 4 dBu Frequency Response 20 20 kHz 2 dB 4 dBu out recom load impedance THD Noise less than 05 40 Hz 20 kHz max 4 dBu out Unit Conformity CE FCC Exempt Unit Construction All Steel Size 1 65 H x 5 1 W x 4 25 D 4 2 cm x 13 cm x 10 8 cm Weight 1 lb 45 kg Shipping Size...

Page 5: ...5 Designator Drawing ...

Page 6: ...6 Block Diagram INPUT 1 10 dBV 4 dBu 10 dBV 4 dBu INPUT 2 OUTPUT 1 OUTPUT 2 ...

Page 7: ... XLR MALE 2 9 11 4 T1 XFMR LINE OUT 2 9 11 4 T2 XFMR LINE OUT 7 8 9 6 10 2 3 4 1 5 11 12 J4A EURO 12 POS IN2 IN1 IN2 IN1 OUT2 OUT1 OUT2 OUT1 PN 03949 FOR BB22 PN 03949 FOR BB22 PN 00961 FOR LT22 PN 00961 FOR LT22 NOTE J1 J2 J3 FOR BB22 ONLY J4 FOR LT22 ONLY CHANNEL 1 CHANNEL 2 1 2 J1 PHONO 1 S GOLD 1 2 J5 PHONO 1 S GOLD RB 2 24 99 BB 22 ONLY LT 22 ONLY GND GND GND GND Schematic ...

Page 8: ...e 110 1985 1995 2006 2007 Rane Corporation Sound System Interconnection Cause prevention of ground loops Interfacing balanced unbalanced Proper pin connections and wiring Chassis ground vs signal ground Ground lift switches RaneNote ...

Page 9: ...ng Society AES has issued a standards document for interconnection of pro audio equipment It is AES48 titled AES48 2005 AES standard on inter connections Grounding and EMC practices Shields of connectors in audio equipment containing active circuitry Rane s policy is to accommodate rather than dictate However this docu ment contains suggestions for external wiring changes that should ideally only ...

Page 10: ...rely eliminated What makes a ground loop current annoying is when the audio signal is affected Unfortunately many manufacturers of balanced au dio equipment design the internal grounding system improperly thus creating balanced equipment that is not immune to the cabling s noise currents This is one reason for the bad reputation sometimes given to balanced interconnect A second reason for balanced...

Page 11: ...y balanced lines and nothing but balanced lines This is why they were developed Further that you tie the shield to the chassis at the point it enters the chassis and at both ends of the cable more on both ends later Since standard XLR cables come with their shields tied to pin 1 at each end the shells are not tied nor need be this means equipment using 3 pin XLR type connectors must tie pin 1 to t...

Page 12: ...2 CONDUCTOR SHIELDED CABLE 2 CONDUCTOR SHIELDED CABLE SHIELD RED BLACK SHIELD RED BLACK SHIELD RED BLACK SHIELD RED BLACK SHIELD RED BLACK SHIELD CHASSIS GROUND CHASSIS GROUND SIGNAL GROUND S R T G BALANCED OUTPUTS BALANCED INPUTS MALE FEMALE MALE FEMALE 1 2 3 C 1 3 2 2 C 3 1 2 1 3 ...

Page 13: ...e Another way to create the necessary isolation is to use a direct box Origi nally named for its use to convert the high impedance high level output of an electric guitar to the low impedance low level input of a recording console it allowed the player to plug directly into the console Now this term is com monly used to describe any box used to convert unbalanced lines to balanced lines NOT CONNEC...

Page 14: ...nterference by providing an RF path through a small capacitor 0 1 or 0 01 microfarad ce ramic disc connected from the lifted end of the shield to the chassis This is referred to as the hybrid shield termination where the sending end is bonded to the chassis and the receiving end is capacitively coupled See Neutrik s EMC XLR for example The fact that many modern day installers still follow this one...

Page 15: ... switch If after hooking up your system it exhibits excessive hum or buzzing there is an incompatibility somewhere in the system s grounding configuration In addition to these spe cial cable assemblies that may help here are some more things to try 1 Try combinations of lifting grounds on units supplied with lift switches or links It is wise to do this with the power off 2 If you have an entirely ...

Page 16: ...nd do not make the cross coupled modification of tying the ring and sleeve together Winning the Wiring Wars Use balanced connections whenever possible with the shield bonded to the metal chassis at both ends Transformer isolate all unbalanced connections from balanced connec tions Use special cable assemblies when unbalanced lines cannot be transformer isolated Any unbalanced cable must be kept un...

Page 17: ... Ott Noise Reduction Techniques in Electronic Systems 2nd Edi tion Wiley New York 1988 7 Cal Perkins Measurement Techniques for Debugging Electronic Systems and Their Instrumentation The Proceedings of the 11th International AES Conference Audio Test Measurement Portland OR May 1992 pp 82 92 Audio Engineering Society New York 1992 8 Macatee RaneNote Grounding and Shielding Audio Devices Rane Corpo...

Page 18: ...LR NOT A TRANSFORMER NOR A CROSS COUPLED OUTPUT STAGE FEMALE BALANCED XLR EITHER A TRANSFORMER OR A CROSS COUPLED OUTPUT STAGE BALANCED TRS NOT A TRANSFORMER NOR A CROSS COUPLED OUTPUT STAGE BALANCED TRS EITHER A TRANSFORMER OR A CROSS COUPLED OUTPUT STAGE FLOATING UNBALANCED CABLE CONNECTORS to to SHIELD NC to to SHIELD NC to to SHIELD ONLY TO EUROBLOCK to to SHIELD NC to to GROUND to GROUND From...

Page 19: ... TRS EITHER A TRANSFORMER OR A CROSS COUPLED OUTPUT STAGE FLOATING UNBALANCED TRS TIP RING SLEEVE SLEEVE IN UNIT NC OR 3 5 mm UNBALANCED TS TIP SLEEVE UNBALANCED RCA TIP SLEEVE BALANCED EUROBLOCK to to SHIELD ONLY TO XLR PIN 1 to to SHIELD ONLY TO EUROBLOCK to to SHIELD NC to to SHIELD ONLY TO TRS SLEEVE to to GROUND to GROUND to to GROUND to GROUND From Output To Input ...

Page 20: ...2 3 1 C 2 1 3 2 nput Output RED BLACK RED BLACK SHIELD RED BLACK BLACK FEMALE FEMALE 3 BLACK 2 RED 1 SHIELD RED RED SHIELD RED SHIELD RED RED BLACK N C N C RED RED 3 NC 2 RED 1 SHIELD 2 RED 1 SHIELD 3 BLACK 2 RED 1 NC 1 NC 3 BLACK 2 RED 1 SHIELD SHIELD FEMALE FEMALE FEMALE RED SHIELD RED BLACK SHIELD RED RED BLACK 2 CONDUCTOR SHIELDED CABLE 2 CONDUCTOR SHIELDED CABLE 2 CONDUCTOR SHIELDED CABLE 2 C...

Page 21: ...1 3 2 To Inp From O SHIELD N C BLACK RED SHIELD N C BLACK RED BLACK RED 3 BLACK 2 RED 1 NC SHIELD BLACK RED BLACK BLACK RED RED SHIELD RED SHIELD RED SHIELD RED SHIELD RED 2 CONDUCTOR SHIELDED CABLE 2 CONDUCTOR SHIELDED CABLE 2 CONDUCTOR SHIELDED CABLE 1 CONDUCTOR SHIELDED CABLE 1 CONDUCTOR SHIELDED CABLE S SHIELD T RED S BLACK T RED S BLACK T RED 12 S SHIELD R BLACK T RED S BLACK T RED CROSS COUP...

Page 22: ... RED S SHIELD T RED 3 BLACK 2 RED 1 SHIELD 3 BLACK 2 RED 1 SHIELD SHIELD BLACK RED SHIELD SHIELD BLACK RED SHIELD BLACK RED SHIELD BLACK RED SHIELD RED SHIELD RED BLACK RED N C N C BLACK RED BLACK RED BLACK RED RED SHIELD RED 2 CONDUCTOR SHIELDED CABLE 2 CONDUCTOR SHIELDED CABLE 2 CONDUCTOR SHIELDED CABLE 2 CONDUCTOR SHIELDED CABLE 1 CONDUCTOR SHIELDED CABLE 1 CONDUCTOR SHIELDED CABLE From Output ...

Page 23: ...LACK 2 RED 1 SHIELD BLACK SHIELD RED BLACK SHIELD RED SHIELD BLACK RED SHIELD BLACK RED SHIELD RED SHIELD RED SHIELD RED SHIELD RED 24 S BLACK T RED CROSS COUPLED OUTPUT ONLY CONNECT BLACK TO SHIELD AT THIS END AND SET GROUND LIFT SWITCH TO GROUNDED IF PRESENT BLACK SHIELD RED BLACK RED 2 CONDUCTOR SHIELDED CABLE S BLACK T RED SHIELD BLACK RED BLACK RED 2 CONDUCTOR SHIELDED CABLE 2 CONDUCTOR SHIEL...

Page 24: ...imited warranty extends to all purchasers or owners of the product during the warranty period beginning with the original retail purchase Rane Corporation does not however warrant its products against any and all defects 1 arising out of material or workmanship not provided or furnished by Rane or 2 resulting from abnormal use of the product or use in violation of instructions or 3 in products rep...

Page 25: ... repair facility in the country where purchased or to the Rane factory in the U S in the original packaging or a replacement supplied by Rane with all transportation costs and full insurance paid each way by the purchaser or owner ALL REMEDIES AND THE MEASURE OF DAMAGES ARE LIMITED TO THE ABOVE SERVICES IT IS POSSIBLE THAT ECONOMIC LOSS OR INJURY TO PERSON OR PROPERTY MAY RESULT FROMTHE FAILURE OF...

Page 26: ...ion of the warranty card NOTICE ItisnotnecessarytoregisterinordertoreceiveRaneCorporation sstandard two year limited warranty WARRANTY REGISTRATION is made and tracked by model and serial numbers only not by the purchaser s or owner s name Therefore any warranty correspondence or inquires must include the model and serial number of the product in question Be sure to fill in the model and serial nu...

Page 27: ...ent 3 Remote power supply if applicable Repaired products purchased in the U S will be returned prepaid freight via the same method they were sent to Rane Products purchased in the U S but sent to the factory from outside the U S must include return freight funds and the sender is fully responsible for all customs procedures duties tariffs and deposits In order to qualify for Rane s one year exten...

Page 28: ...BB 22 BALANCE BUDDY 4 225 0 15 2 5 5 1 0 775 0 35 1 636 OUTPUT 1 OUTPUT 2 4dBu 4dBu 10dBV 10dBV INPUT 2 INPUT 1 BALANCE BUDDY RANE CORP 1 2 BB 22 ...