background image

Data Sheet-2

Parameter

Specification

Limit

Units

Conditions/Comments

Delay Range

0.011 to 327.68

1%

msec

..........Increment Size

10 µs or 1 ms

Independently controllable

..........Readout

5 digit LED

Propagation Delay

11.3

10%

µsec

Sampling Frequency

3.2 MHz

Data Convertion

1-bit Dolby™  Time Link

In/Out Connectors: AD 22

Screw Terminal

#6 spades

..........

AD 22B

XLR

Inputs: Type

Active balanced

Instrumentation type

..........Impedance

20k balanced

1%

ohms

..........Headroom

16 above Sensitivity setting

2

dB

20 Hz - 8 kHz

7 above Sensitivity setting

2

dB

20 kHz

..........Max Level

20

dBu

1 kHz with Sensitivity at +4 dBu

Outputs: Type

Active balanced

..........Impedance

200 balanced

1%

ohms

..........Max Level

20 (>2k ohm); 18 (>600 ohm)

dBu

1 kHz with Sensitivity at +4 dBu

Overall System Gain

0

±1

dB

Output Relays

Yes

Auto-bypass with power loss

LED Thresholds: Clip

4 before converter overload

1

dB

1 kHz

..........Signal Present

-34 below Clip LED

1

dB

1 kHz

Frequency Response

10-30 kHz

0.5

dB

+4 dBu, Sens@+4

THD + Noise

0.1

.05

%

+4 dBu, Sens@+4, 1 kHz, 30k Hz BW

0.2

.1

%

+4 dBu, Sens@+4, 20-20k, 30k Hz BW

Signal-to-Noise Ratio

90

2

dB

+4 dBu, Sens@+4, CCIR-2k

82

2

dB

+4 dBu, Sens@+4

Dynamic Range

98

2

dB

+4 dBu, Sens@+4, 20 Hz - 8 kHz

92

2

dB

+4 dBu, Sens@+4, 8k-20 kHz

106

2

dB

+4 dBu, Sens@+4, 20-20k, CCIR-2k

Crosstalk

>85

dB

1 kHz, +4 dBu, Sens @ +4 dBu

>64

dB

20 kHz, +4 dBu, Sens @ +4 dBu

EMI/RFI Emission - Unit

Certified FCC Part 15J

Class A Device

...............

AD 22B

Meets EMCD 89/336/EEC

CE Certified

; AD 22 is not certified

Unit: Agency Listing

..........120 VAC model

Class 2 Equipment

National Electrical Code

UL

Exempt Class 2 equipment

CSA

Exempt Class 2 equipment

..........230 VAC model
...............

AD 22B

CE-EMC

EMC directive 89/336/EEC

..............

.AD 22 & AD 22B

CE-Safety

Exempt per Art. 1 of LVD 73/23/EEC

Power Supply: Agency Listing

..........120 VAC model

UL

File no. E88261

CSA

File no. LR58948

..........230 VAC model

CE-EMC

EMC directive 89/336/EEC

CE-Safety

LV directive 73/23/EEC

Power Supply Requirement

18 VAC w/center tap

0.1

Vrms

RS 1 (see data sheet)

..........Maximum Current

650

mA

RMS Current from Remote Supply

Unit: Construction

All Steel

..........Size

1.75"H x 19"W x 8.5"D (1U)

(4.4 cm x 48.3 cm x 21.6 cm)

..........Weight

6 lb (w/o power supply)

(2.7 kg)

Shipping: Size

4.25" x 20.3" x 13.75"

(11 cm x 52 cm x 35 cm)

.........Weight

10 lb

(4.5 kg)

Note: 0 dBu=0.775 Vrms