background image

 

 

 
4.

 

Check your audio sources by playing back files and monitoring the meters inside each green 
input block. Check the microphones in the same way.  

Note: 

Condenser microphones will need +48V phantom power and less gain than dynamic 

microphones. 

5.

 

Use the Master Remote DR6 to assign a source for each zone and check the Output meters.  
After checking all signals, unmute all zones by pressing 

Unmute 

on the upper right menu.  

6.

 

Save the customization by pressing 

Save Baseline

 on the upper right menu (by default, Rane 

DSP will recall the Baseline if power is lost).  

 

 

7.

 

Press 

Save As

 and add the name of your venue and date, i.e. 

1010X_Restaurant_FrenchCuisine_July_2018”

.    

Note:

 Turn the power amplifier 

ON

 and slowly adjust the volume to set levels for each zone. 

8.

 

Press 

Disconnect

 inside Halogen. Terminal 1010x will always remember the last configuration 

applied. Now your system is ready to be used. 

 

Web Remote Control 

   

To remotely access and adjust the same parameters available for the Master Remote DR6, you can 
connect Terminal 1010x to a local network and use a Web browser to control it.

 

Connect the 

Computer Ethernet Port on the rear of Terminal 1010x to a router (preferably wireless). 

 

 

Once the 

Ethernet Link

 

LED

 is lit, Terminal 1010x will display an IP address on the front display. 

Type in the IP address into a Web browser from a smartphone or portable device connected to the 
same network.  

Tip:

 Bookmark the URL to remember it for quick access.

 

 

Security Access 

 

By default, the template comes with two different levels of security:  
 

Username: 

admin 

Password:

 1234

 

 

This gives you full access, control of all zones, sources, levels, EQ, paging, and muting. 

 

Username: 

user 

Password:

 0000 

 

This gives you access to

 

all zones, sources, selections, and level adjustments.

 

  
 
 
 
 
 
 
 
 
 
 
 
 