Basic Safety Instructions 

1171.0000.42 - 08 

Page 5 

2.  Before you move or transport the product, read and observe the section titled "Transport". 

3.  As with all industrially manufactured goods, the use of substances that induce an allergic reaction 

(allergens) such as nickel cannot be generally excluded. If you develop an allergic reaction (such as a 
skin rash, frequent sneezing, red eyes or respiratory difficulties) when using a Rohde & Schwarz 
product, consult a physician immediately to determine the cause and to prevent health problems or 
stress.  

4.  Before you start processing the product mechanically and/or thermally, or before you take it apart, be 

sure to read and pay special attention to the section titled "Waste disposal/Environmental protection", 
item 1. 

5.  Depending on the function, certain products such as RF radio equipment can produce an elevated 

level of electromagnetic radiation. Considering that unborn babies require increased protection, 
pregnant women must be protected by appropriate measures. Persons with pacemakers may also be 
exposed to risks from electromagnetic radiation. The employer/operator must evaluate workplaces 
where there is a special risk of exposure to radiation and, if necessary, take measures to avert the 
potential danger. 

6.  Should a fire occur, the product may release hazardous substances (gases, fluids, etc.) that can 

cause health problems. Therefore, suitable measures must be taken, e.g. protective masks and 
protective clothing must be worn. 

7.  Laser products are given warning labels that are standardized according to their laser class. Lasers 

can cause biological harm due to the properties of their radiation and due to their extremely 
concentrated electromagnetic power. If a laser product (e.g. a CD/DVD drive) is integrated into a 
Rohde & Schwarz product, absolutely no other settings or functions may be used as described in the 
product documentation. The objective is to prevent personal injury (e.g. due to laser beams). 

8.  EMC classes (in line with EN 55011/CISPR 11, and analogously with EN 55022/CISPR 22, 

EN 55032/CISPR 32) 

 

Class A equipment:  
Equipment suitable for use in all environments except residential environments and environments 
that are directly connected to a low-voltage supply network that supplies residential buildings  
Note: Class A equipment is intended for use in an industrial environment. This equipment may 
cause radio disturbances in residential environments, due to possible conducted as well as 
radiated disturbances. In this case, the operator may be required to take appropriate measures to 
eliminate these disturbances. 

 

Class B equipment: 
Equipment suitable for use in residential environments and environments that are directly 
connected to a low-voltage supply network that supplies residential buildings 

Repair and service 

1.  The product may be opened only by authorized, specially trained personnel. Before any work is 

performed on the product or before the product is opened, it must be disconnected from the AC supply 
network. Otherwise, personnel will be exposed to the risk of an electric shock.  

Summary of Contents for ZCPS

Page 1: ...R S ZCPS Converter Power Supply User Manual User Manual 1325 6424 02 01 I H2 Test Measurement...

Page 2: ...81671 M nchen Germany Phone 49 89 41 29 0 Fax 49 89 41 29 12 164 E mail info rohde schwarz com Internet www rohde schwarz com Subject to change Data without tolerance limits is not binding R S is a r...

Page 3: ...e of the product The product is used for its designated purpose if it is used in accordance with its product documentation and within its performance limits see data sheet documentation the following...

Page 4: ...ation item 7 Signal words and their meaning The following signal words are used in the product documentation in order to warn the reader about risks and dangers Indicates a hazardous situation which i...

Page 5: ...afety is not observed either at all or to the extent necessary electric shock fire and or serious personal injury or death may occur 1 Prior to switching on the product always ensure that the nominal...

Page 6: ...t be fuse protected in such a way that anyone who has access to the product as well as the product itself is adequately protected from injury or damage 14 Use suitable overvoltage protection to ensure...

Page 7: ...masks and protective clothing must be worn 7 Laser products are given warning labels that are standardized according to their laser class Lasers can cause biological harm due to the properties of the...

Page 8: ...n permitted 5 If a cell develops a leak the fluid must not be allowed to come into contact with the skin or eyes If contact occurs wash the affected area with plenty of water and seek medical aid 6 Im...

Page 9: ...s substances or fuels can cause health problems and lead to environmental damage For additional information about environmental protection visit the Rohde Schwarz website Instrucciones de seguridad el...

Page 10: ...el uso del producto Deber n tenerse en cuenta todas las dem s informaciones de seguridad como p ej las referentes a la protecci n de personas que encontrar n en el cap tulo correspondiente de la docu...

Page 11: ...l producto se emplea de forma sin nima el t rmino CUIDADO Las palabras de se al corresponden a la definici n habitual para aplicaciones civiles en el rea econ mica europea Pueden existir definiciones...

Page 12: ...la tensi n preseleccionada en el producto coincida con la de la red de alimentaci n el ctrica Si es necesario modificar el ajuste de tensi n tambi n se deber n cambiar en caso dado los fusibles corre...

Page 13: ...efectuadas por un electricista especializado 13 En el caso de dispositivos fijos que no est n provistos de fusibles interruptor autom tico ni otros mecanismos de seguridad similares el circuito de ali...

Page 14: ...presario operador tiene la obligaci n de evaluar y se alizar las reas de trabajo en las que exista un riesgo elevado de exposici n a radiaciones 6 Tenga en cuenta que en caso de incendio pueden despre...

Page 15: ...r ni fuego Debe evitarse el almacenamiento a la luz directa del sol Las celdas y bater as deben mantenerse limpias y secas Limpiar las conexiones sucias con un pa o seco y limpio 3 Las celdas o bater...

Page 16: ...vos el ctricos usados no se deben desechar con los residuos dom sticos sin clasificar sino que deben ser recogidos por separado Rohde Schwarz GmbH Co KG ha elaborado un concepto de eliminaci n de resi...

Page 17: ...ems Rohde Schwarz has been certified for exam ple according to the ISO9001 and ISO14001 management systems Environmental commitment Energy efficient products Continuous improvement in environmental su...

Page 18: ...ument up to date and to be informed about new application notes related to your instrument please send an e mail to the Customer Support Center stating your instrument and your wish We will take care...

Page 19: ...Contents R S ZCPS 3 User Manual 1325 6424 02 01 Contents 1 Introduction 4 2 Preparing the unit 5 3 Converter Connections and Status LEDs 10 4 Replacing Fuses 12...

Page 20: ...he maximum current that is needed by any converter model at that specific voltage The Converter Power Supply has been designed and tested in accordance with the EC Certificate of Conformity and has le...

Page 21: ...h the instrument or in electronic format on the documenta tion CD ROM In addition read and observe the safety instructions in the following sec tions Notice that the data sheet may specify additional...

Page 22: ...ou retain the packaging It is advisable to keep the original packing material in order to prevent control elements and connec tors from being damaged if the Converter Power Supply has to be transpor t...

Page 23: ...ient air supply both front intake and rear outlet must be clear and the airflow must not be impeded The unit must be positioned at least 10 cm away from the wall The ambient temperature must lie withi...

Page 24: ...ed that none of the voltage levels at the inputs exceed permissible limits Explanation Measuring circuits as defined in section 6 7 4 of EN61010 1 Measuring category I is intended for measurements on...

Page 25: ...ter 2 Switch the power switch to I The power switch has two positions 0 The unit is disconnected from the AC supply I The unit is receiving power from the AC supply 2 5 Switching the unit Off To switc...

Page 26: ...The connectors are keyed with pin and groove indicated by red marks and rotated by 180 degrees relative to each other Fig 3 1 Converter Connector Contact S i g n a l Input Output 1 DC Supply 13 8 V O...

Page 27: ...converter power supply board are enabled by the con nected converter a high level on the power control input POWER_CTRL acti vates them In active state the supply voltages are supervised if one of th...

Page 28: ...re 2 2 Shock hazard Before replacing a fuse make sure that the instrument is switched off and disconnected from all power supplies Always use fuses supplied by Rohde Schwarz as spare parts or fuses of...