Remote Control Commands
R&S
®
SMJ100A
627
Operating Manual 1403.7458.32 ─ 14
Example:
MMEM:CDIR 'D:\user\waveform'
sets the default directory.
BB:ARB:WSEG:NEXT 2
selects segment 2 to be output.
BB:ARB:TRIG:SMOD NEXT
selects extended trigger mode next, i.e. the segment specified
with command
:BB:ARB:WSEG:NEXT
will be output.
BB:ARB:SEQ AUTO
selects trigger mode Auto.
BB:ARB:WAV:SEL 'multi_wv1'
loads multi segment waveform
multi_wv1.wv
. Generation of
segment 2 starts.
BB:ARB:WSEG:NEXT 3
switched at once to output of segment 3.
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:WSEGment:NEXT:EXECute
Triggers manually switchover to the subsequent segment in the mutli segment file. A
manual trigger can be executed only when an internal next segment source
(
BB:ARB:WSEG:NEXT:SOUR INT
) has been selected.
To perform a switchover to any segment within the multi segment file, select the next
segment with the command
BB:ARB:WSEG:NEXT
.
This command is disabled, if a sequencing play list is enabled.
Example:
BB:ARB:WSEG:NEXT:SOUR INT
selects internal next segment source.
BB:ARB:WSEG:NEXT 2
selects segment 2 to be output.
BB:ARB:WSEG:NEXT:EXEC
executes a switchover to the next segment.
Usage:
Event
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:WSEGment:NEXT:SOURce?
Queries the next segment source.
Return values:
<Source>
INTernal
*RST:
INTernal
Example:
BB:ARB:WSEG:NEXT:SOUR?
queries the next segment source.
Usage:
Query only
Manual operation:
See
SOURce Subsystem
Summary of Contents for SMJ100A
Page 34: ...Preface R S SMJ100A 18 Operating Manual 1403 7458 32 14 Notes on Screenshots...
Page 86: ...Preparing for Use R S SMJ100A 70 Operating Manual 1403 7458 32 14 LXI Configuration...
Page 826: ...Remote Control Commands R S SMJ100A 810 Operating Manual 1403 7458 32 14 UNIT Subsystem...
Page 828: ...Maintenance R S SMJ100A 812 Operating Manual 1403 7458 32 14 Storing and Packing...
Page 844: ...Hardware Interfaces R S SMJ100A 828 Operating Manual 1403 7458 32 14 BERT Connector...