Remote Control Commands
R&S
®
SMJ100A
622
Operating Manual 1403.7458.32 ─ 14
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:DELete
<Filename>
Deletes the configuration file. The configuration files are used to create multi segment
waveform files.
Setting parameters:
<Filename>
string
Example:
MMEM:CDIR 'D:\user\waveform'
sets the default directory.
BB:ARB:WSEG:CONF:DEL 'multi1'
deletes configuration file
multi1.inf_mswv
.
Usage:
Setting only
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:LEVel[:MODE]
<Mode>
This command selects the level mode for the multi segment waveform.
Parameters:
<Mode>
UNCHanged | ERMS
UNCHanged
The segments are output exactly as defined in the files.
ERMS
The segments are output so that all segments have the same
rms value.
*RST:
UNCHanged
Example:
BB:ARB:WSEG:CONF:LEV:MODE UNCH
selects level mode unchanged. The segments are output as
defined in the waveform file.
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:MARKer:ESEGment
<Mode>
Enables/disables the generation of an additional marker restart signal in the output
waveform file.
If additional marker generation is enabled, the existing marker signals in the individual
segment waveform files are not considered.
SOURce Subsystem
Summary of Contents for SMJ100A
Page 34: ...Preface R S SMJ100A 18 Operating Manual 1403 7458 32 14 Notes on Screenshots...
Page 86: ...Preparing for Use R S SMJ100A 70 Operating Manual 1403 7458 32 14 LXI Configuration...
Page 826: ...Remote Control Commands R S SMJ100A 810 Operating Manual 1403 7458 32 14 UNIT Subsystem...
Page 828: ...Maintenance R S SMJ100A 812 Operating Manual 1403 7458 32 14 Storing and Packing...
Page 844: ...Hardware Interfaces R S SMJ100A 828 Operating Manual 1403 7458 32 14 BERT Connector...