Remote control commands
R&S
®
RTO6
2024
User Manual 1801.6687.02 ─ 05
TRIGger<m>:ETHernet:FRAMe:TCONdition
<TypeOperator>
Sets the type operator to trigger on a specific length/type value pattern or a range.
Suffix:
<m>
.
1..3
Parameters:
<TypeOperator>
EQUal | NEQual | LTHan | LETHan | GTHan | GETHan |
INRange | OORange
EQUal | NEQual | LTHan | LETHan | GTHan | GETHan
Equal, Not equal, Less than, Less than or equal, Greater Than,
Greater than or equal. These conditions require a destination
address to be set with
TRIGger<m>:ETHernet:FRAMe:TMIN
.
INRange | OORange
In range, Out of range. Set the minimum and maximum value of
the range with
TRIGger<m>:ETHernet:FRAMe:TMIN
and
TRIGger<m>:ETHernet:FRAMe:TMAX
*RST:
EQUal
TRIGger<m>:ETHernet:FRAMe:TMAX
<TypePatternMax>
Sets the end value of a length/type range, if
is set to
INRange
or
OORange
.
Suffix:
<m>
.
1..3
Parameters:
<TypePatternMax>
TRIGger<m>:ETHernet:FRAMe:TMIN
<TypePatternMin>
Specifies a length/type value, or sets the start value of a pattern range.
Suffix:
<m>
.
1..3
Parameters:
<TypePatternMin>
24.17.16.3
Decode results
In all
BUS<m>:ETHernet:WORD<n>
commands, the suffix <m> selects the serial bus
and the suffix <n> selects the word number in the decode table.
As an example, a set of query commands for bus #1 and word #1 is shown in the fol-
lowing, together with examples for results of these queries:
●
BUS1:ETH:WCOunt?
!2
●
BUS1:ETH:WORD1:STATe?
!OK
Protocols