Remote control commands
R&S
®
RTO6
1857
User Manual 1801.6687.02 ─ 05
Parameters:
<DataPatternTo>
Numeric or string pattern, see
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:LIN:BORDer
<SearchName>,<Endianness>
SEARch:TRIGger:LIN:BORDer?
<SearchName>
Sets the byte order (endianness) of the data transfer.
Parameters:
<Endianness>
BENDian | LENDian
BENDian
Big endian, data is analyzed and evaluated in the order of
reception.
LENDian
Little endian, the instrument reads the complete data, reverses
the byte order of the data, and compares it with the specified
data word.
*RST:
BENDian
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:LIN:DLECondition
<SearchName>,<DLCOperator>
SEARch:TRIGger:LIN:DLECondition?
<SearchName>
Operator to set the data length for search on LIN data.
For Big Endian transfer direction, you can trigger on a number of bytes less than the
data length of the frame, that means, on the first bytes that are transmitted. For Little
Endian transfer direction, the exact number of data bytes in the frame must be set.
Example: The data word to be sent is
12 34 56
, and it is sent little endian by the LIN
node. With Data length ≥ 2 and Transfer = Big endian, you trigger on the data of the
first two bytes, that is
56 34
. With Data length = 3 and Transfer = Little endian, you trig-
ger on the required data word
12 34 56
.
The number of data bytes to be found is set with
.
See also:
Parameters:
<DLCOperator>
EQUal | GETHan
For little endian transfer direction, EQUal must be set.
*RST:
GETHan
Parameters for setting and query:
<SearchName>
Protocols