background image

This manual describes the following R&S

®

RTB2000 models:

R&S

®

RTB2002 (1333.1005K02)

R&S

®

RTB2004 (1333.1005K04)

© 2017 Rohde & Schwarz GmbH & Co. KG
Mühldorfstr. 15, 81671 München, Germany
Phone: +49 89 41 29 - 0
Fax: +49 89 41 29 12 164
Email: 

[email protected]

Internet: 

www.rohde-schwarz.com

Subject to change – Data without tolerance limits is not binding.
R&S

®

 is a registered trademark of Rohde & Schwarz GmbH & Co. KG.

Trade names are trademarks of their owners.

Throughout this manual, products from Rohde & Schwarz are indicated without the 

®

 symbol , e.g.

R&S

®

RTB2000 is indicated as R&S

 

RTB2000.

Summary of Contents for RTB2K-COM4

Page 1: ...R S RTB2000 Digital Oscilloscope Getting Started Getting Started 1333 1605 02 03 Q 52...

Page 2: ...41 29 0 Fax 49 89 41 29 12 164 Email info rohde schwarz com Internet www rohde schwarz com Subject to change Data without tolerance limits is not binding R S is a registered trademark of Rohde Schwar...

Page 3: ...e of the product The product is used for its designated purpose if it is used in accordance with its product documentation and within its performance limits see data sheet documentation the following...

Page 4: ...ation item 7 Signal words and their meaning The following signal words are used in the product documentation in order to warn the reader about risks and dangers Indicates a hazardous situation which i...

Page 5: ...afety is not observed either at all or to the extent necessary electric shock fire and or serious personal injury or death may occur 1 Prior to switching on the product always ensure that the nominal...

Page 6: ...t be fuse protected in such a way that anyone who has access to the product as well as the product itself is adequately protected from injury or damage 14 Use suitable overvoltage protection to ensure...

Page 7: ...masks and protective clothing must be worn 7 Laser products are given warning labels that are standardized according to their laser class Lasers can cause biological harm due to the properties of the...

Page 8: ...ckaging until they are ready to be used 4 Cells and batteries must not be exposed to any mechanical shocks that are stronger than permitted 5 If a cell develops a leak the fluid must not be allowed to...

Page 9: ...back obligations and disposal obligations for manufacturers within the EU Contact your Rohde Schwarz customer service center for environmentally responsible disposal of the product 3 If products or th...

Page 10: ...ument up to date and to be informed about new application notes related to your instrument please send an e mail to the Customer Support Center stating your instrument and your wish We will take care...

Page 11: ...8 1 2 4 Release Notes and Open Source Acknowledgment 8 2 Preparing for Use 9 2 1 Unpacking and Checking the Instrument 9 2 2 Positioning the Instrument 10 2 3 Starting the Instrument 11 2 3 1 Powerin...

Page 12: ...Contents R S RTB2000 4 Getting Started 1333 1605 02 03...

Page 13: ...sed by dangerous situations Safety information is provided as follows The Basic Safety Instructions in different languages are delivered as a prin ted brochure with the instrument Throughout the docum...

Page 14: ...in the following sections Make sure that all fan openings are unobstructed and the airflow perfo rations are unimpeded The minimum distance from the wall is 10 cm Signal levels at the input connector...

Page 15: ...schwarz com manual rtb2000 Getting started manual Introduces the R S RTB2000 and describes how to set up the product A printed English version is included in the delivery User manual Contains the des...

Page 16: ...data sheet contains the technical specifications of the R S RTB2000 It also lists the options with their order numbers and optional accessories The brochure provides an overview of the instrument and...

Page 17: ...e or anything is missing immediately contact the carrier as well as your distributor Make sure not to discard the box and packing mate rial Packing material Retain the original packing material If the...

Page 18: ...ount using a rack mount kit The order number of the rack mount kit is given in the data sheet The installation instructions are part of the rack mount kit Risk of injury if feet are folded out The fee...

Page 19: ...cm between the instruments Ensure that the instruments do not draw in the preheated air from their neighbors When mounting the instrument in a rack observe the instructions of the rack manufacturer to...

Page 20: ...pply and the main power switch on the rear panel is in position I 2 Press the STANDBY key The key is located in the bottom left corner of the front panel The instrument performs a system check and sta...

Page 21: ...shut down the instrument 2 Switch the main power switch at the rear of the instrument to position 0 3 Disconnect the AC power cable from the AC power supply Risk of losing data If you switch off the...

Page 22: ...5x20 mm 250V T2 5H slow blow IEC60127 2 5 Shock hazard Before replacing a fuse make sure that the instrument is switched off and disconnected from all power supplies Always use fuses supplied by Rohd...

Page 23: ...1 Front panel of R S RTB2004 with 4 input channels 1 Display 2 Horizontal and vertical setup controls 3 Trigger settings action and analysis controls 4 Analog input channels 2 channels at R S RTB2002...

Page 24: ...voltages The maximum input voltage on channel inputs must not exceed 400 V peak and 300 V RMS For the external trigger input the maximum input voltage is 400 V peak and 300 V RMS Transient overvoltage...

Page 25: ...afety information of the probe manufacturer Explanation According to section AA 2 4 of EN 61010 2 030 measuring circuits without any measurement category are intended for measurements on circuits whic...

Page 26: ...pe A 8 USB 2 0 type A interface to connect a mouse or a keyboard or a USB flash drive for storing and reloading instrument settings and measurement data and to update the firmware AUX OUT 9 Multi purp...

Page 27: ...a Local Area Network LAN It supports up to 1 Gbit s USB type B 2 USB 2 0 interface of type B device USB for remote control of the instrument Note Electromagnetic interference EMI can affect the measur...

Page 28: ...TB2002 RTB2K 72 RTB2004 RTB B242 RTB2K 204 RTB2004 RTB B242 RTB B1 RTB2K 204M RTB2004 RTB B243 RTB B1 RTB2K 304M RTM3004 RTM B222 RTM3K 24 RTM3002 RTM B223 RTM3K 32 RTM B222 RTM B223 RTM B225 RTM B221...

Reviews: