Remote Commands
R&S
®
FSW
847
User Manual 1173.9411.02 ─ 43
[SENSe:]POWer:ACHannel:SPACing:ALTernate<ch>
<Spacing>
This command defines the distance from transmission channel to alternate channels.
For MSR signals, this command defines the distance from the CF of the first Tx chan-
nel in the first sub block to the lower alternate channel. To configure the spacing for the
upper alternate channel in asymmetrical configurations, use the
ACHannel:SPACing:UALTernate<ch>
command.
If you set the channel spacing for the first alternate channel, the R&S
FSW adjusts the
spacing of alternate channels of a lower order, but not the other way round (not for
MSR signals). The command works hierarchically: to set a distance from the transmis-
sion channel to the 2nd and 3rd alternate channel, you have to define a spacing for the
2nd alternate channel first.
Suffix:
<ch>
.
1..n
Alternate channel number
Parameters:
<Spacing>
Range:
100 Hz to 2000 MHz
*RST:
40 kHz (ALT1), 60 kHz (ALT2), 80 kHz (ALT3), ...
Default unit: Hz
Manual operation:
See
See
[SENSe:]POWer:ACHannel:SPACing:CHANnel<ch>
<Spacing>
This command defines the distance between transmission channels.
If you set the channel spacing for a transmission channel, the R&S
FSW sets the spac-
ing of the lower transmission channels to the same value, but not the other way round.
The command works hierarchically: to set a distance between the 2nd and 3rd and 3rd
and 4th channel, you have to set the spacing between the 2nd and 3rd channel first.
Suffix:
<ch>
.
1..n
Tx channel number
Parameters:
<Spacing>
Range:
14 kHz to 2000 MHz
*RST:
20 kHz
Default unit: Hz
Manual operation:
See
[SENSe:]POWer:ACHannel:TXCHannel:COUNt
<Number>
This command defines the number of transmission channels.
The command works for measurements in the frequency domain.
Configuring and Performing Measurements