TRIGger[:SEQuence]:TIME:RINTerval
<Interval>
This command defines the repetition interval for the time trigger.
Parameters:
<Interval>
2.0 ms to 5000
Range:
2 ms to 5000 s
*RST:
1.0 s
Default unit: S
Example:
TRIG:SOUR TIME
Selects the time trigger input for triggering.
TRIG:TIME:RINT 50
The sweep starts every 50 s.
Manual operation:
See
14.7.4.2
Configuring Gated Measurements
............................................................................................... 1055
..................................................................................... 1056
[SENSe:]SWEep:EGATe:CONTinuous:PCOunt
............................................................... 1057
[SENSe:]SWEep:EGATe:CONTinuous:PLENgth
..............................................................1057
[SENSe:]SWEep:EGATe:CONTinuous[:STATe]
................................................................1057
..................................................................................1058
...................................................................................1058
[SENSe:]SWEep:EGATe:LEVel:RFPower
....................................................................... 1058
[SENSe:]SWEep:EGATe:LEVel[:EXTernal<port>]
............................................................ 1059
..................................................................................1059
................................................................................. 1060
......................................................................................1060
[SENSe:]SWEep:EGATe
<State>
This command turns gated measurements on and off.