The following commands configure a fixed reference marker.
CALCulate<n>:DELTamarker<m>:FUNCtion:FIXed:RPOint:MAXimum[:PEAK]
CALCulate<n>:DELTamarker<m>:FUNCtion:FIXed:RPOint:X
............................................ 344
CALCulate<n>:DELTamarker<m>:FUNCtion:FIXed:RPOint:Y
............................................ 345
CALCulate<n>:DELTamarker<m>:FUNCtion:FIXed:RPOint:Y:OFFSet
................................ 345
CALCulate<n>:DELTamarker<m>:FUNCtion:FIXed[:STATe]
.............................................. 345
CALCulate<n>:DELTamarker<m>:FUNCtion:FIXed:RPOint:MAXimum[:PEAK]
This command moves the fixed reference marker to the peak power.
Suffix:
<n>
.
<m>
Example:
CALC:DELT:FUNC:FIX:RPO:MAX
Sets the reference point level for delta markers to the peak of
the selected trace.
Usage:
Event
Manual operation:
See
CALCulate<n>:DELTamarker<m>:FUNCtion:FIXed:RPOint:X
<RefPoint>
This command defines the horizontal position of the fixed delta marker reference point.
The coordinates of the reference may be anywhere in the diagram.
Suffix:
<n>
.
<m>
Parameters:
<RefPoint>
Numeric value that defines the horizontal position of the refer-
ence.
For frequency domain measurements, it is a frequency in Hz.
For time domain measurements, it is a point in time in s.
*RST:
Fixed Reference: OFF
Example:
CALC:DELT:FUNC:FIX:RPO:X 128 MHz
Sets the frequency reference to 128 MHz.
Manual operation:
See
Analyzing Results