Return values:
<SourceList>
Comma separated list. Each supported value is represented as
a string.
Usage:
Query only
Firmware/Software:
V1.0.15.20
CONFigure:EVDO:MEAS<i>:RFSettings:EATTenuation
<RFInputExtAtt>
Defines an external attenuation (or gain, if the value is negative), to be applied to the
RF input connector.
This command is only relevant for the standalone scenario. For the combined signal
path scenario, use:
●
●
Parameters:
<RFInputExtAtt>
Range:
-50 dB to 90 dB
*RST:
0 dB
Default unit: dB
Example:
See
Specifying General Measurement Settings
Firmware/Software:
V1.0.3.3
Manual operation:
See
"External Attenuation (Input)"
3.5.2.2
Analyzer Settings
The following commands configure the input signal and the view selection in remote
control.
CONFigure:EVDO:MEAS<i>:RFSettings:BCLass
.............................................................. 320
CONFigure:EVDO:MEAS<i>:RFSettings:CHANnel
............................................................321
CONFigure:EVDO:MEAS<i>:RFSettings:FREQuency
........................................................322
CONFigure:EVDO:MEAS<i>:RFSettings:FOFFset
.............................................................322
CONFigure:EVDO:MEAS<i>:RFSettings:ENPower
............................................................322
CONFigure:EVDO:MEAS<i>:RFSettings:UMARgin
............................................................323
CONFigure:EVDO:MEAS<i>:MEValuation:PLSubtype
....................................................... 323
CONFigure:EVDO:MEAS<i>:MEValuation:SFACtor?
.........................................................324
CONFigure:EVDO:MEAS<i>:DISPlay
...............................................................................324
CONFigure:EVDO:MEAS<i>:RFSettings:BCLass
<BandClass>
Selects the Band Class (BC).
If the current center frequency (
) is valid for this band class, the corresponding channel number
) is also calculated and set.
See also