1xEV-DO Signaling
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
168
User Manual 1173.9511.02 ─ 11
Firmware/Software:
V1.0.15.0
Manual operation:
See
CONFigure:EVDO:SIGN<i>:RFPower:OUTPut?
Queries the output power at the selected RF output connector: the sum of the "1xEV-
DO Power" (
).
The allowed value:
Range (Output Power) = -130 dBm to -5 dBm (RFx Com) or -120
dBm to 3 dBm (RFx Out)
; please also notice the ranges quoted in the data sheet.
Return values:
<OutputPower>
Range:
-100 dBm to 100 dBm
*RST:
-70 dBm
Default unit: dBm
Example:
See
Usage:
Query only
Firmware/Software:
V1.0.15.0
Manual operation:
See
CONFigure:EVDO:SIGN<i>:RFPower:EPMode
<ExpPowerMode>
Selects the algorithm which the tester uses to configure its input path.
Parameters:
<ExpPowerMode>
MANual | OLRule | MAX | MIN | AUTO
MANual:
Manual setting, according to
OLRule:
According to open loop rule
MAX:
Maximum AT power
MIN:
Minimum AT power
AUTO:
Autoranging, according to received signal
*RST:
OLR
Example:
See
chapter 2.5.1.1, "Specifying General Settings"
Firmware/Software:
V1.0.15.0
Manual operation:
See
CONFigure:EVDO:SIGN<i>:RFPower:MANual
<ManualExpPower>
Defines the expected absolute input power at the input connector for "Expected Power
Mode: Manual" (
Command Reference
深圳德标仪器