Troubleshooting
R&S
®
TSMA6B
96
User Manual 4901.4026.02 ─ 01
9
Troubleshooting
For all troubleshooting procedures, connect keyboard, mouse and a monitor to the
R&S TSMA6B.
............................................................................................... 96
................................................................................................ 97
Verify scanner link / recall device info using TsmeDeviceManager
R&S TSMA6B automatically switches off after power on
......................................101
Scanner is not found from software (R&S ROMES, R&S NESTOR)
Verify scanner connection LAN settings
................................................................105
............................................................................ 108
WLAN access point not detected by external PC, mobile or tablet
Web GUI not accessible via WLAN
.......................................................................114
Web GUI locally not accessible
.............................................................................115
........................................................................... 117
device not detected by R&S TSMA6B
.................................................119
...............................................................................121
9.1
LED indicated errors
●
"Mode" LED blue blinking fast
−
Selftest Error
–
Check the scanner connection (see
Chapter 9.6, "Verify scanner connection
–
Evaluate the
Selftestresult.txt
Chapter 9.2, "Evaluate selftest file"
●
"State" LED red blinking (2 Hz)
−
Temperature Warning
–
Check the ventilation openings and the operating temperature.
–
Switch off the device and let it cool down.
●
"State" LED red continuous
−
Overheated Unit
–
Switch off the device and let it cool down.
–
Check the ventilation openings and switch on the device. If the problem occurs
again, analyze the
Selftestresult.txt
(see
●
"Meas" LED red blinking (2 Hz)
−
Application Error
–
Refer to the application note of the used software.
●
"Pwr" LED off after startup
−
Power Error
–
Contact R&S support.