OM-PHHC-26 HOT HOLDING CABINET

4.  Check all doors to ensure that they are sealing properly, are properly aligned, 

and open and shut freely.

5.  Confirm there is adequate supply voltage for the unit.
6.  Plug in unit and turn on main on/off power switch.
7.  Allow unit time heat to temperature. If temperature adjustments are required, 

the temperature adjustment control is located on the face of the unit above 
the door.

8.  Refer to the front of this manual for serial number location. Please record this 

information in your manual. It will be necessary when ordering replacement 
parts or requesting warranty service.

9.  Confirm that the unit is holding temperature. Set control to desired 

temperature for your particular ambient and altitude.

10. Allow your unit to operate for approximately 2 hours before putting in 

product to allow interior of unit to heat to storage temperature.

ELECTRICAL SUPPLY

The wiring should be done by a qualified electrician in accordance with local 
electrical codes. A properly wired and grounded outlet will assure proper 
operation. Please consult the data tag attached to the compressor to ascertain 
the correct electrical requirements. Supply voltage and amperage requirements 
are located on the serial number tag located inside the unit on the left interior 
side wall.

CABINET DOORS

The doors on the PHHC-26 are reversible. The doors can be reversed by 
removing the hinge screws located on the opposite side of the cabinet opening. 
The smaller half size doors need to be rotated 180° and then secured into the 
screw holes on the opposite side.
This same procedure can be followed for the full size door. In addition the hinges 
that attach to the full size door will also need to be rotated 180° along with the 
door latch. The cam lift hinge bushing within the cabinet mounted hinges will 
need to be removed and inserted into the hinge to allow for proper pitch for door 
closure.

SHELVES

Cabinet shelves are adjustable in 1” increments. To adjust shelving the shelf will 
need to be removed. Remove all 4 clips for the shelf and set all 4 at the new 
desired height making certain all 4 clips are at the same level. Re-install shelf 
onto the clips.

OPERATION

WARNING: EVEN THOUGH YOUR REACH-IN WAS DESIGNED FOR HEAVY USE, 

EXCESSIVE AND UNNECESSARY DOOR OPENINGS SHOULD BE AVOIDED IN 

ORDER TO MAINTAIN PROPER BOX TEMPERATURE.

NOTE:  

THE HEATED CABINET IS DESIGNED AS A HOLDING CABINET AND WILL 

MAINTAIN A TEMPERATURE RANGE OF 70° - 180°F. THE HEATED CABINET 

IS NOT INTENDED TO COOK OR HEAT PRODUCT. PRODUCT ENTERING THE 

CABINET SHOULD ENTER AT A MINIMUM OF 140°F.

Your heated holding unit will maintain proper temperatures when utilized properly. 
It is strongly recommended that the doors be kept closed as much as possible. 
Make sure the doors close properly after each use.
Your heated reach in unit was equipped with a temperature adjustment control 
located on the top front of the unit. See Figure A. The temperature control has been 
preset at the factory. Once the unit is powered on, allow 45 minutes to 1 hour for 
the inside temperature to reach the factory set point of 160°F. Once the unit has 
reached the set point it may then be loaded with product.
        

 

 

 

Figure A

TEMPERATURE CONTROL SETTINGS

PART NO.

RANDELL CONTROL SETTINGS / PHHC-26

REF. NO DEF.

RF CNT1001

XR01CX-4N4LQ

Heated Upright Cabinet

1001

CODE

LOCKED

FACTORY SET

PARAMETER

Set

Thermostat set point

160

HY

Thermostat Differential (hysteresis)

5

LS

Lower Set Point

150

US

Upper Set Point

180

ot

Offset Room Temp

0

od

Output delay @ Startup

0

AC

Anti-Cycle Time (min off after cycle)

0

CY

Compressor ON time (probe failure)

0

Cn

Compressor OFF (probe failure)

0

CH

Kind of Action (Heating or Cooling)

Ht

CF

°C / °F

F

rE

Resolution 0.0°C (only °C)

in

dy

Display Delay

0

ALC

Alarm Configuration

Ab

AU

Maximum Temperature Alarm

190

AL

Minimum Temperature Alarm

140

iP

Digital Input Plarity

CL

iF

Digital Input Configuration

EA

di

Digital Input Delay

5

dC

Comp. and Fan Status when open door

no

rd

Regulation with door open

n

PC

Type of Probe

ntc

rL

Software Info

1.7

Pt

Software info

12