OM-9560 & 9570 DROP-IN SERIES HEATED WELLS

INSTALLATION

RECEIVING SHIPMENT

Upon arrival, examine the exterior of the shipping crate for signs of abuse. It is 
advisable that the shipping crate be partially removed, in order to examine the 
cabinet for any possible concealed damages which might have occurred during 
shipment. If no damages are evident, replace the crate in order to protect the 
unit during storage and local delivery. If the unit is damaged, the damage should 
be noted on the delivery slip or bill of lading and signed to that effect. A claim 
must be filed immediately against the carrier indicating the extent and esti mated 
cost of damage occurred.

LOCATING YOUR NEW UNIT

The following conditions should be considered when selecting a location for 
your unit:
1.  Floor and Counter top load - The area on which the unit will rest must be free 

of vibration and suitably strong enough to support the combined weights of 
the unit plus the maximum product load weight.

2.  Clearance - There must be a combined total of at least 3” clearance on all 

sides of the unit.

ELECTRICAL SUPPLY

The wiring should be done by a qualified electrician in accordance with local 
electrical codes. A properly wired, and grounded outlet is required for proper 
operation. Consult the data plate attached to the control panel for the correct 
supply voltage and amperage requirements of the unit.

INSTALLATION CHECKLIST

After the final location of the unit has been determined refer to the following 
checklist prior to start up:
1.  Check all wiring to ensure that there are no kinked, bare, or loose wires.
2.  Check that unit fits properly in cabinet and ensure that it is properly leveled.
3.  Refer to the front of this manual for serial number location. Please record 

this information in your manual on page 2 now. It will be necessary when 
ordering replacement parts or requesting warranty service.

4.  Confirm that the unit is holding temperature. Set controls to desired 

temperature.

5.  Check unit for any signs of leaking.

9560 INSTALLATION

1.  When installing Model 9560 Drop-in Hot Food unit, a clearance of 1/4” on 

all sides and 4-1/4” below unit must be maintained from all combustible 
materials.

2.  Control panel must be inserted into cutout before main unit is installed.
3.  Secure unit to top and seal with NSF approved silicon.

 

 

INSTALLATION REQUIREMENTS

MODEL

“A”

“B”

“C”

“D”

9560-1

18.5”

26”

16.5”

14.25”

9560-2

31.75”

26”

30.125”

14.25”

9560-3

45.5”

26”

43.75”

20”

9560-4

59.25”

26”

57.375”

26”

9560-5

73”

26”

71”

32”

9560-6

86.75”

26”

84.625”

38”

* REVISED CUTOUT SIZE FROM 22.5” TO 22.63” 10-18-95
* REVISED CUTOUT SIZE FROM 14” TO 14.25” 6-1-95